시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안 (Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement)

  • 문재승;신민용;안성철;유문곤;김수근
    • 한국의료질향상학회지
    • /
    • 제20권1호
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.

방사선관리구역의 공간선량률 교육을 위한 가상현실 시뮬레이터의 개발과 유용성 평가 (Development and Usefulness Evaluation of Virtual Reality Simulator for Education of Spatial Dose Rate in Radiation Controlled Area)

  • 서정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.493-499
    • /
    • 2023
  • This study developed education contents of measuring spatial dose with virtual reality simulation and applied to students majoring radiological science. The virtual reality(VR) contents with measuring spatial dose rate in the radiation controlled area was developed based on the simulation from pilot study. In this simulation, the tube voltage and tube current can be set from 60 to 120 kVp in 10 kVp steps and 10 to 40 mAs in 10 mAs increments, and the distance from source can be set from 30 to 400 cm continuously. Iron and lead shields can be placed between the source and the detector, and shielding thickness can be set by 1 mm increments ranging from 1 to 20 mm. We surveyed to students for evaluating improvement of understanding spatial dose rate between before and after education by VR simulation. The survey was conducted with 5 questions(X-ray exposure factors, effects by distance from the source, effects from using shield, depending on material and thickness of shield, concept and measuring of spatial dose rate) and all answers showed significant improvement. Therefore, this VR simulation content will be well used in education for spatial dose rate and radiation safety environments.

핵의학과 분배실 내의 공간선량률 측정 (Measurement of the Spatial Dose Rate for Distribution Room in Department of Nuclear Medicine)

  • 박정규;조의현
    • 디지털콘텐츠학회 논문지
    • /
    • 제13권2호
    • /
    • pp.151-157
    • /
    • 2012
  • 방사선 구역 내부의 공간선량은 의학의 발전과 더불어 방호시설이 잘 되어 있어도 작업종사자의 피폭을 증가시킬 우려가 있다. 핵의학과 내의 분배실은 항상 공간선량이 존재하므로 작업종사자의 피폭선량을 예측하기 위하여 분배실 내부의 공간선량을 측정, 분석 하였다. 핵의학과 $^{18}F$ 분배실의 공간선량률 측정결과 최대 $6.78{\pm}0.083{\mu}Sv/h$, $^{99m}Tc$, $^{131}I$ 분배실의 공간선량률이 최대 $9.248{\pm}0.013{\mu}Sv/h$로 나타났다. 또한, $^{18}F$ 분배실의 경우 1m 거리에서 간호사가 IV시 연간 외부피폭선량은 $42.5{\mu}Sv$로 나타났다. 분배실의 분배창을 기준으로 오른쪽 사방향에서 공간선량률이 높게 나타났다. 따라서 방사성의약품을 분배실에서 분배할 경우 방사선 작업종사자의 머무르는 시간을 짧게 해야 하며, 분배창의 오른쪽 사방향의 경우 피폭을 줄이기 위한 분배창의 설계가 필요하며, IV시 작업종사자의 개인피폭선량을 줄이기 위한 최선의 노력이 필요하다고 사료된다.

고용량 옥소 치료 시 3차원적 공간선량률 측정 및 연구 (The Study and Measurement of Three Dimensional Spatial Dose Rate from Radioiodine Therapy)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제7권3호
    • /
    • pp.251-257
    • /
    • 2013
  • 고용량 옥소 치료 시 수평면, 수직면, 방위각에 따라 3차원적으로 방출되는 공간선량률을 측정하였다. 정확한 측정을 위해 기하학적 구조의 알루미늄 틀을 제작하여 100 cm 거리에서, 높이 (5 측정점), 방위각 (8 측정점), 시간적 간격 (6 측정점)을 각각 나누어서 분석하였다. 수직면상 공간선량률 분포는 $^{131}I$을 경구 투여 24 시간 후 환자로부터 거리 100 cm, 높이 100 cm 지점에서 환자군 평균 71.85 ${\mu}Sv/h$로 가장 높았다. 수분섭취를 통한 공간선량률 감쇠 정도를 두 그룹으로 나누어 실험하였다. $^{131}I$을 경구 투여 24시간 뒤 거리 100 cm, 높이 100 cm에서 공간선량률 분포가 A 실험군은 44.9 ${\mu}Sv/h$이고 B 실험군은 100.28 ${\mu}Sv/h$이다. A 실험군이 B 실험군과 비교하여 고용량 옥소 치료 시 수분섭취 정도에 따라 약 53 %의 피폭경감 효과를 확인하였다.

Technegas 스캐닝 후 중력환기에 의한 공간선량율 측정 (The Measurement of Spatial Dose Rate by Gravity Ventilation after Technegas Scanning)

  • 김성빈;원도연
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.667-674
    • /
    • 2019
  • Technegas를 사용한 검사는 단순 확산 누적을 통해 폐 영상을 이미지화하기 때문에 검사를 마친 후에 검사실이 오염될 수 있다. 따라서 방사선 작업 종사자와 검사를 기다리는 환자는 technegas 흡입으로 인한 내부 피폭의 영향을 받게 된다. 이에 중력환기 전후의 시간경과에 따른 공간선량율 분포를 비교, 분석함에 따라 방사선사, 의료진, 대기 환자의 피폭선량 저감화 방법을 모색하고자 한다. 중력환기 전후 환자의 호흡기 위치에서 거리별, 각도별로 공간선량율을 10분 동안 측정하고 평균값, 표준 편차 및 감소율을 계산하였다. 실험 결과, 중력 환기 전후 감소율은 최고 95.31%였고 가장 높은 감소율은 1 ~ 3분 사이에서 나타났다. 중력환기를 통해서 방사선 작업종사자, 대기환자, 환자 보호자 및 간호사의 피폭선량을 감소시킬 수 있다. 결론적으로 중력환기를 통한 피폭선량 감소 결과는 방호 최적화를 이루는 역할을 할 것이며 ICRP 103에서 권고한 의료 피폭 저감화에 부합된다.

핵의학 검사에서 환자로부터의 공간선량률 측정 (Measurement of the Spatial Dose Rates from Radioactive Patients during Nuclear Medicine Studies)

  • 박명환;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권1호
    • /
    • pp.73-76
    • /
    • 2002
  • In order to evaluate the exposure to the radiologic technologists from patients who had been administrated with radiopharmaceuticals, we measured the spatial dose rates at 5 cm, 50 cm, and 100 cm from skin surface of patients using an proportional digital surveymeter, both 5 min after injection and right before the studies. In results, the exposure to the technologists in each procedure was small, compared nth the dose limits of the medical workers. However, the dose-response relationships in cancer and hereditary effects, referred to as the stochastic effects, have been assumed linear and no threshold models ; therefore, the exposure should be minimized. For this purpose, the measurements of spatial dose rate distributions were thought to be useful.

  • PDF

MCNPX 시뮬레이션을 이용한 무납 방사선 차폐 시트 기반의 공간산란 저감화 평가 (Evaluating the Reduction of Spatial Scattering based on Lead-free Radiation Shielding Sheet using MCNPX Simulation)

  • 양승우;박금별;허예지;박지군
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.367-373
    • /
    • 2020
  • 물체와 X선의 상호작용로 발생하는 산란선으로 야기되는 공간 산란선량은 대부분이 저에너지 영역의 전자기파로 인체에 비교적 쉽게 흡수되어 방사선 피폭정도가 증가하게 된다. 이러한 공간 산란 선량은 방사선작업 종사자 및 환자의 방사선 피폭 정도 지표로도 사용되고 있으며 간접적으로 발생하는 공간 산란 선량을 줄여 피폭을 저감화하기 위한 방안의 필요성이 마련될 필요성이 있다. 이에 본 연구에서는 공간산란 선량을 저감화 방안으로 무납 방사선 차폐 시트를 제시하였고 가슴 X선 촬영검사를 기준으로 몬테카를로(MC; Monte Carlo) 시뮬레이션을 수행하여 거리 변화에 따른 갑상샘과 생식선 위치에서 흡수되는 산란선의 흡수선량을 산출하였고 실측치와 차폐율을 비교 평가하였다.

Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS)

  • Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.146-155
    • /
    • 2016
  • As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.

전신 PET/CT 검사에서 공간선량률 측정 (Measurement of the Spatial Dose Rates During PET/CT Studies)

  • 박명환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.257-260
    • /
    • 2006
  • 전신 PET/CT 검사에서 $^{18}F-FDG$의 방사성의약품을 투여한 환자가 방사선원이 되기에 환자로부터 종사자의 피폭선량 예측을 위한 PET 검사실에서 환자 주변의 공간선량률을 측정 분석하였다. 연간 개인피폭선량은 대학병원의 핵의학 분야에 근무하는 종사자가 방사선종양학과와 소규모병원의 진단방사선 분야에 비해 검사 중에 환자로부터 방출되는 공간선량률에 의하여 개인피폭선량이 높게 나타났다. 그리고 PET/CT 검사에서 $^{18}F-FDG$를 이용하는 경우에 $^{99m}Tc$ 보다 공간선량률이 $4{\sim}6$배 정도로 훨씬 높고, 촬영실 전체에 공간선량률이 분포함을 알 수 있었다. 따라서 방사성의약품 투여 후 안정실이나 PET 검사 중에 촬영실 내에서는 항상 방사선 방어의 기본인 시간은 짧게, 거리는 멀리, 차폐를 고려하여 PET 검사를 수행하는 것이 매우 중요하고, 환자로부터의 공간선량률에 따른 종사자의 개인피폭선량을 줄이기 위한 최선의 노력이 필요하다.

  • PDF

F-18 FDG를 이용한 핵의학 검사에서 주변 선량의 안전성 평가 (The Safety Assessment of Surrounding Dose on Nuclear Medicine Test by Use The F-18 FDG)

  • 곽병준;지태정;민병인
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.157-162
    • /
    • 2009
  • Radioactive medicines are used a lot owing to the increase of a PET-CT examination using glucose metabolism useful for the early diagnosis of diseases. Therefore, the spatial dose that is generated from patients and their surroundings causes the patients' guardians and health professional to be exposed to radiation. However, they get unnecessarily exposed to radiation because medical institutions lack in space for isolation and recognition of the examination. This research intended to examine the spatial dose rates by measuring the dose emitted from the patient for 48 hours to whom F-18 FDG was administered. The spatial dose rates that were measured 100cm away from the patient's body after F-18 FDG was injected were $65.88{\mu}$Sv/hr at 60-minute point, $45.13{\mu}$Sv/hr at 90-minute point, $9.88{\mu}$Sv/hr at 6-hour point, and $1.24{\mu}$Sv/hr at 12-hour point. When the dose that the guardian and health professional got was converted into the annual(240-day working) accumulative dose, it was examined that the guardian received 81.56 mSv/yr and health professional received 49.36mSv/yr. In addition, the result has revealed that the dose that the patient received from one time of PET-CT examination was 3.75mSv/yr, which is 1.5 times more when compared with the annual natural radiation exposure dose.