• Title/Summary/Keyword: Fabrication methods

Search Result 994, Processing Time 0.034 seconds

The treatment of an edentulous patient with conventional complete denture and CAD/CAM complete denture (Conventional한 방식과 CAD/CAM System을 이용한 완전 무치악 환자 동시 수복 증례)

  • Cho, Sungyoon;Lee, Joonseok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.42-49
    • /
    • 2020
  • In patients with fully edentulous jaw, treatment of complete dentures should be carried out in many stages when following the conventional methods. Therefore there were disadvantages such as multiple visits to dental clinic is inevitable. In addition, errors caused by polymerization shrinkage, which happens during the fabrication of denture, and difficulties in reproduction of damaged or lost denture were considered as disadvantages. But nowadays, computer-aided design and computer-aided manufacturing (CAD/CAM) system is widely used in dentistry and it has begun to expand its spectrum in manufacturing complete dentures. Using CAD/CAM system to fabricate complete dentures can reduce the number of patient's visit and clinical chair time, since taking impression, recording jaw relation, and selection of artificial teeth are performed at the same time during the first visit, and delivering of dentures during the second visit is possible. In addition, because 3D-Printing technology is used, errors by polymerization shrinkage can be reduced. Among the companies that fabricate complete dentures using CAD/CAM system, DENTCA CAD/CAM denture (DENTCA Inc., Los Angeles, CA, USA) is the most commercialized company. In this case, we treated patients of complete dentures using conventional complete denture method and DENTCA CAD/CAM denture system in the same patient. We would like to report this case because we have achieved good results not only in functional aspects of pronunciation, chewing, and swallowing but also in aesthetic aspects.

Small Broadband Phased Array Antenna with Compact Phase-Shift Circuits (간결한 위상 변위 회로를 갖는 소형 광대역 위상 배열 안테나)

  • 한상민;권구형;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.10
    • /
    • pp.1071-1078
    • /
    • 2003
  • In this paper, the planar, compact, and broadband phased array antenna system for IMT-2000 applications has been investigated. Two methods far designing a low-cost and low-complex beam-farming network are proposed. First, a new compact and broadband phase shifter with continuously controlled phase bits is designed by using parallel coupled lines. Second, its equivalent phase delay line is suggested to be capable of replacing the complex phase shifter with a reference phase bit on a phased array antenna. For the purpose of achieving the broadband system, in addition to the broadband phase shifter, a wide-slot antenna with a ground reflector is utilized as an element antenna. Therefore, the phased array antenna system has achieved compact size, broad bandwidth, and wide steering angle, although it has low complexity and low fabrication cost. The 3${\times}$1 phased array antenna system has a compact size of 1.6 λ${\times}$ l.6 λ, which is the sufficient ground plane of the wide-slot antenna. Experimental results present that the S$\_$11/ has less than 15 dB within the band and its radiation patterns on an E-plane have the capability of steering an antenna beam from -29$^{\circ}$to +30$^{\circ}$.

Exposure to Volatile Organic Compounds and Possibility of Exposure to By-product Volatile Organic Compounds in Photolithography Processes in Semiconductor Manufacturing Factories

  • Park, Seung-Hyun;Shin, Jung-Ah;Park, Hyun-Hee;Yi, Gwang-Yong;Chung, Kwang-Jae;Park, Hae-Dong;Kim, Kab-Bae;Lee, In-Seop
    • Safety and Health at Work
    • /
    • v.2 no.3
    • /
    • pp.210-217
    • /
    • 2011
  • Objectives: The purpose of this study was to measure the concentration of volatile organic compound (VOC)s originated from the chemicals used and/or derived from the original parental chemicals in the photolithography processes of semiconductor manufacturing factories. Methods: A total of four photolithography processes in 4 Fabs at three different semiconductor manufacturing factories in Korea were selected for this study. This study investigated the types of chemicals used and generated during the photolithography process of each Fab, and the concentration levels of VOCs for each Fab. Results: A variety of organic compounds such as ketone, alcohol, and acetate compounds as well as aromatic compounds were used as solvents and developing agents in the processes. Also, the generation of by-products, such as toluene and phenol, was identified through a thermal decomposition experiment performed on a photoresist. The VOC concentration levels in the processes were lower than 5% of the threshold limit value (TLV)s. However, the air contaminated with chemical substances generated during the processes was re-circulated through the ventilation system, thereby affecting the airborne VOC concentrations in the photolithography processes. Conclusion: Tens of organic compounds were being used in the photolithography processes, though the types of chemical used varied with the factory. Also, by-products, such as aromatic compounds, could be generated during photoresist patterning by exposure to light. Although the airborne VOC concentrations resulting from the processes were lower than 5% of the TLVs, employees still could be exposed directly or indirectly to various types of VOCs.

A Comparative Study of ITO Glass Ablation Using Femtosecond and Nanosecond Lasers (펨토초 레이저와 나노초 레이저를 이용한 ITO Glass의 어블레이션 비교 연구)

  • Jeon, Jin-Woo;Shin, Young-Gwan;Kim, Hoon-Young;Choi, Wonsuk;Ji, Seok-Young;Kang, Hee-Shin;Ahn, Sanghoon;Chang, Won Seok;Cho, Sung-Hak
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.356-360
    • /
    • 2017
  • Indium tin oxide (ITO) provides high electrical conductivity and transparency at visible and near-IR wavelengths. ITO is widely used as a transparent electrode for the fabrication of LCDs, OLEDs, and many kinds of optical applications. It is widely employed for electrodes in various electric and display sectors because of its transparency in the visible range and high conductivity. Therefore, one issue is removing a specific area of a layer of material such as ITO or metallic film on a substrate, without affecting the properties of the substrate. ITO-on-glass removal using a laser is friendlier to the environment than traditional methods. In this study, ablation of ITO film on glass using a femtosecond-laser micromachining system (wavelength 1026 nm, pulse duration 150 fs) and a nanosecond-laser micromachining system (wavelength 1027 nm, pulse duration 5 ns) are described, compared, and analyzed.

The fabrication of PVDF organic thin films by thermal evaporation deposition method and their molecular orientation properties (열증착법을 이용한 PVDF 유기박막의 제조와 분자배향특성)

  • 임응춘;이덕출
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.122-128
    • /
    • 1997
  • In this study, the PVDF organic thin films were fabricated by thermal evaporation deposition which is one of the dry-processing methods. The distance from heat source to substrate was 5 cm. The substrate temperature was maintained at $30 ^{\circ}C$ during deposition. The working pressure was about $2.0\times10^{-5}$Torr and the temperature of heat source was increased at the rate of 6 to $8^{\circ}C$/min. At $270^{\circ}C$, the shutter was opened and the deposition of PVDF has stared. As the electrical field intensity increased, $\alpha$ peaks such $530\textrm{cm}^{-1},795\textrm{cm}^{-1},1182\textrm{cm}^{-1}$ decreased, and $\beta$ peaks such as $510\textrm{cm}^{-1},1273\textrm{cm}^{-1}$ increased. The intensity of $530\textrm{cm}^{-1}$ peak was stronger than that of $510\textrm{cm}^{-1}$ peak velow the 71.4 kV/cm, intensity of electrical field. This result showed the characteristic of film mainly due to $\alpha$-mode. According to these results, the molecular structure of PVDF thin film is transformed from $\alpha$-mode with TGT or TG'T to $\beta$-mode with planar zigzag structure TT, as increasing of intensity of electrical field.

  • PDF

Fabrication of superhydrophobic $TiO_2$ thin films by wet process (습식 공정법에 의한 초발수 $TiO_2$ 박막 제조)

  • Kim, Jin-Ho;Jung, Hyun-Ho;Hwang, Jong-Hee;Lim, Tae-Young;Choi, Duk-Gun;Cheong, Deock-Soo;Kim, Sae-Hoon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.5
    • /
    • pp.262-267
    • /
    • 2009
  • Superhydrophobic $TiO_2$ thin films were successfully fabricated on a glass substrate by wet process. Layer-by-layer (LBL) deposition and liquid phase deposition (LPD) methods were used to fabricate the thin films of micro-nano complex structure with a high roughness. To fabricate superhydrophobic $TiO_2$ thin films, the (PAH/PAA) thin films were assembled on a glass substrate by LBL method and then $TiO_2$ nanoparticles were deposited on the surface of (PAH/PAA) thin film by LPD method, Subsequently, hydrophobic treatment using fluoroalkyltrimethoxysilane (FAS) was carried out on the surface of prepared $TiO_2$ thin films. The $TiO_2$ thin film fabricated with 45 minutes immersion time on $(PAH/PAA)_{10}$ showed the RMS roughness of 65.6nm, water contact angel of $155^{\circ}$ and high transmittance of above 80% (>650nm in wavelength) after the hydrophobic treatment. The Surface morphologies, optical properties and contact angel of prepared thin films with different experimental conditions were measured by field emission scanning electron microscope (FE-SEM), atomic force microscope (AFM), UV-Vis spectrophotometer and contact angle meter.

Strength Development of Fiber Reinforced Lean Concrete Using Fly Ash and Reject Ash under Different Compaction Methods including Small Scale Roller Vibrator (플라이애쉬와 리젝트애쉬를 활용한 섬유보강 빈배합 콘크리트의 강도 특성 및 롤러다짐을 활용한 현장적용 실험)

  • Kim, Seung-Won;Jang, Young-Jae;Park, Young-Hwan;Park, Cheol-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.543-551
    • /
    • 2012
  • Road pavements in Korea generally show shorter service life than the predicted one. There are many reasons for this phenomenon including increased traffic load and other attacks from exposure conditions. In order to extend a service life and upgrade the pavement, a new multi-functional composite pavement system is being developed in Korea. This study is to investigate the performances of fiber-reinforced lean concrete for pavement base. This study considered mineral admixtures of fly ash and reject ash. The reject ash is defined as ash that does not meet the specifications for fly ash so that it cannot be used as a supplemental material for cement replacement. Due to the inherent property of lean concrete, compaction during the fabrication of specimens is a key factor. Therefore, this study suggests an appropriate compaction method. From the test results, the compressive strengths of the concrete satisfied the required limit of 5 MPa at 7 days. When a compaction roller was used to mimic actual field conditions, the strength development seemed to be influenced by the compaction energy rather than hydration of cement itself.

Dental application of glass-ceramic materials for aesthetic restoration (심미수복을 위한 글라스-세라믹 재료의 치과 응용)

  • Bae, Tae Sung
    • The Journal of the Korean dental association
    • /
    • v.58 no.7
    • /
    • pp.435-442
    • /
    • 2020
  • Porcelain is the first ceramic material to be introduced into dentistry. Porcelain jacket crown was introduced by Dr. Charles H Land in 1886, which was an excellent aesthetic dental restoration but has not been widely used due to high firing shrinkage and low tensile strength. Then metal-ceramic system, which combines the esthetic properties of ceramics and the mechanical properties of metals, was introduced and nowadays it is still used in dental clinical field. However, the metal-ceramic system has shown some problems, such as increased lightness by reflection of light at opaque layer, shadow beneath the gingival line due to the block-out of light by metal coping, exposure of metal in margin part, bond failure between metal and porcelain, oxidation of metal coping during firing the porcelain, etc. Recently, along with the advance of fabrication methods of dental ceramics, the all-ceramic restorations with high esthetic and mechanical properties has increased and gradually replaced metal-ceramic restorations. Especially, CAD/CAM technology has opened a new era in fabricating the dental ceramic restorations. This overview will take a look at the past, present and future possibility of the dental ceramic materials.

  • PDF

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

Survey study on the Preference of Dental Medical Personnel for Dental CAD/CAM Milling Machines (치과용 CAD/CAM 밀링기에 대한 치과의료종사자들의 선호도 조사)

  • Song, Eun Sung;Kim, Bongju;Lim, Young-Joon;Lee, Jun Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.188-198
    • /
    • 2018
  • Purpose: Recently, according to the development of digital technology, computer aided design/computer aided manufacture (CAD/CAM) system is widely used for fabrication of various dental prostheses in the field of dentistry. This study aims to survey the present state and awareness of CAD/CAM system on domestic dental field, and to supply the advice for the application of the new system. Materials and methods: In this questionnaire survey was conducted for a total of 298 dentists, dental hygienist and dental technicians of the whole country including the dental hospital of Seoul National University for two months from November to December, 2016 through mail. Results: The most important purpose to consider when purchasing a dental CAD/CAM milling machine were the performance of the milling machine (64.43%) and the use of milling machine was the highest with 49.33% of manufacturing for dental prosthesis and customized implant abutment. In addition, more than 60% of respondents answered positively about the purchase of new milling machine if the CAD/CAM milling machine was improved to satisfactory performance. Conclusion: This survey results show that the improved CAD/CAM milling machine would be play an important role in the dental industry in preparation for digitization and the 4th industrial revolution.