• 제목/요약/키워드: FFT method

검색결과 689건 처리시간 0.022초

Natural frequency analysis of tractor tire with different ground contacts and inflation pressures

  • Cuong, Do Minh;Sihong, Zhu
    • Coupled systems mechanics
    • /
    • 제9권5호
    • /
    • pp.455-471
    • /
    • 2020
  • This paper presents the results of the study of vertically natural frequency of tractor tires are effected by changing different ground contacts and inflation pressures using the Free Decay Method. The results show that the natural frequencies of the tire are not affected while the vertical acceleration increased strongly due to the increase of inflation pressure when the tire performs free decay vibration on rigid ground. In addition, the number of natural frequency peaks of the tire also increases with increasing tire inflation pressure. On the other hand, the natural frequencies of the tractor tire increases strongly while the vertical acceleration decreases slightly with the increase of tire inflation pressure as the tire performs free decay vibration on soft soil. Further, the natural frequencies of tire-soil system are always higher than that of tire only, and it changed with changing the soil depth. Results also show the natural frequency of tire and tire-soil system is in the range of 3.0 to 10.0 Hz that lie within the most critical natural frequency range of the human body. These findings have to be mentioned and used as design parameters of the tractor suspension system.

A Robust Audio Fingerprinting System with Predominant Pitch Extraction in Real-Noise Environment

  • Son, Woo-Ram;Yoon, Kyoung-Ro
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.390-395
    • /
    • 2009
  • The robustness of audio fingerprinting system in a noisy environment is a principal challenge in the area of content-based audio retrieval. The selected feature for the audio fingerprints must be robust in a noisy environment and the computational complexity of the searching algorithm must be low enough to be executed in real-time. The audio fingerprint proposed by Philips uses expanded hash table lookup to compensate errors introduced by noise. The expanded hash table lookup increases the searching complexity by a factor of 33 times the degree of expansion defined by the hamming distance. We propose a new method to improve noise robustness of audio fingerprinting in noise environment using predominant pitch which reduces the bit error of created hash values. The sub-fingerprint of our approach method is computed in each time frames of audio. The time frame is transformed into the frequency domain using FFT. The obtained audio spectrum is divided into 33 critical bands. Finally, the 32-bit hash value is computed by difference of each bands of energy. And only store bits near predominant pitch. Predominant pitches are extracted in each time frames of audio. The extraction process consists of harmonic enhancement, harmonic summation and selecting a band among critical bands.

  • PDF

음향주파수 분석에 의한 엔드밀의 마모상태 추정에 관한 연구 (A Study on the Wear Estimation of End Mill Using Sound Frequency Analysis)

  • 이창희;조택동
    • 대한기계학회논문집A
    • /
    • 제27권8호
    • /
    • pp.1287-1294
    • /
    • 2003
  • The wear process of end mill is so complicated process that a more reliable technique is required for the monitoring and controlling the tool life and its performance. This research presents a new tool wear monitoring method based on the sound signal generated on the machining. The experiment carried out continuous-side-milling for 4 cases using the high-speed-steel end mill under wet condition. The sound pressure was measured at 0.5m from the cutting zone by a dynamic microphone, and was analyzed at frequency domain. As the cutter impacts the workpiece surface, a situation of farced vibration arises in which the dominant forcing frequency is equal to the tooth passing frequency of the cutter. The tooth passing frequency appears as a harmonics form, and end mill flank wear is related with the first harmonic. It is possible to detect end . mill flank wear. This paper proposed the new method of the end mill wear detection.

Condition Monitoring of Low Speed Slewing Bearings Based on Ensemble Empirical Mode Decomposition Method

  • Caesarendra, W.;Park, J.H.;Choi, B.H.;Kosasih, P.B.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.388-393
    • /
    • 2012
  • Vibration condition monitoring at low rotational speeds is still a challenge. Acoustic emission (AE) is the most used technique when dealing with low speed bearings. At low rotational speeds, the energy induced from surface contact between raceway and rolling elements is very weak and sometimes buried by interference frequencies. This kind of issue is difficult to solve using vibration monitoring. Therefore some researchers utilize artificial damage on inner race or outer race to simplify the case. This paper presents vibration signal analysis of low speed slewing bearings running at a low rotational speed of 15 rpm. The natural damage data from industrial practice is used. The fault frequencies of bearings are difficult to identify using a power spectrum. Therefore the relatively improved method of empirical mode decomposition (EMD), ensemble EMD (EEMD) is employed. The result is can detect the fault frequencies when the FFT fail to do it.

  • PDF

2차원 연속 웨이블릿을 이용한 편광 필름 결함 검출 (Polaroid Film Defect Detection Using 2D - Continuous Wavelet Transform)

  • 정창도;김세윤;주영복;윤병주;최병재;박길흠
    • 한국지능시스템학회논문지
    • /
    • 제19권6호
    • /
    • pp.743-748
    • /
    • 2009
  • 본 논문은 2차원 연속 웨이블릿을 이용하여 조명에 의한 불균일한 휘도성분을 제거하여 TFT Display 핵심 부품인 편광필름 영상내의 결함을 검사 할 수 있는 방법을 제안한다. 영상 신호는 불균일한 휘도 분포와 노이즈 신호, 그리고 결함 신호로 구성되어 있다. 영상의 2차원 웨이블릿 변환은 스케일이 다른 여러 성분이 중첩된 다해상도 구조를 형성한다. 본 논문에서는 1차원 미분 가우시안 웨이블릿을 적용하여 영상에 중첩되어 있는 다해상도 성분 중 배경 휘도 성분을 효율적으로 추출하여 제거하는 전처리 기법을 제안한다. 이를 이용하여 원 영상에서 배경 성분을 분리할 수 있어 보다 신뢰성 있게 결함을 검출할 수 있다.

Wavelet 변환을 이용한 고장 전류의 판별에 관한 연구 (A Study on the Application of Wavelet Transform to Faults Current Discrimination)

  • 정종원;조현우;김태우;이준탁
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2002년도 추계학술대회 및 정기총회
    • /
    • pp.427-430
    • /
    • 2002
  • Recently the subject of "wavelet analysis" has be drawn by both mathematical and engineering application fields such as Signal Processing, Compression/Decomposition, Wavelet-Neural Network, Statistics and etc. Even though its similar to Fourier analysis, wavelet is a versatile tool with much mathematical content and great potential for applications. Especially, wavelet transform uses localizable various mother wavelet functions in time-frequency domain. Therefore, wavelet transform has good time-analysis ability for high frequency component, and has good frequency-analysis ability for low frequency component. Using the discriminative ability is more easy method than other conventional techniques. In this paper, Morlet wavelet transform was applied to discriminate the kind of line fault by acquired data from real power transformation network. The experimental result presented that Morlet wavelet transform is easier,and more useful method than the FFT (Fast Fourier Transform).

전두엽과 두정엽의 뇌파를 이용한 쾌적성 평가 방법 (Comfortableness Evaluation Method using EEGs of the Frontopolar and the Parietal Lobes)

  • 김동준;김흥환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권5호
    • /
    • pp.374-379
    • /
    • 2004
  • This paper proposes an algorithm for human sensibility evaluation using 4-channel EEG signals of the prefrontal and the parietal lobes. The algorithm uses an artificial neural network and the multiple templates. The linear prediction coefficients are used as the feature parameters of human sensibility. Comfortableness for chairs and temperature/humidity are evaluated. Many conventional researches have emphasized that a wave of left prefrontal lobe is activated in case of positive sensibility and that of right prefrontal lobe is activated in case of negative sensibility. So the power ratio of a wave is obtained from FFT computation and the results are compared. The results of the comfortableness evaluation for temperature and humidity showed that the outputs of the proposed algorithm coincided with corresponding sensibilities depending on the task of the temperature and the humidity. The . conventional method using a wave is hardly related with comfortableness. And it is also observed that the uncomfortable state due to the high temperature and humidity can be easily changed to the comfortable state by small drop of the temperature and the humidity. It seems to be good results to get 66.7% of evaluation performance in spite of using EEG and the subject independent approach.

Detection and Classification of Demagnetization and Short-Circuited Turns in Permanent Magnet Synchronous Motors

  • Youn, Young-Woo;Hwang, Don-Ha;Song, Sung-ju;Kim, Yong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1614-1622
    • /
    • 2018
  • The research related to fault diagnosis in permanent magnet synchronous motors (PMSMs) has attracted considerable attention in recent years because various faults such as permanent magnet demagnetization and short-circuited turns can occur and result in unexpected failure of motor related system. Several conventional current and back electromotive force (BEMF) analysis techniques were proposed to detect certain faults in PMSMs; however, they generally deal with a single fault only. On the contrary, cases of multiple faults are common in PMSMs. We propose a fault diagnosis method for PMSMs with single and multiple combined faults. Our method uses three phase BEMF voltages based on the fast Fourier transform (FFT), support vector machine(SVM), and visualization tools for identifying fault types and severities in PMSMs. Principal component analysis (PCA) and t-distributed stochastic neighbor embedding (t-SNE) are used to visualize the high-dimensional data into two-dimensional space. Experimental results show good visualization performance and high classification accuracy to identify fault types and severities for single and multiple faults in PMSMs.

오버샘플된 전류신호를 사용한 인버터 구동형 전동기의 베어링 고장검출 시스템 (High Precison Bearing Fault Detect System of Inverter Driven System Using Oversampled Current Signals)

  • 김남훈;김민회;최창호;이상훈;최경호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.506-508
    • /
    • 2007
  • In this paper, the induction motor bearing fault diagnosis system using current signals which are measured by over-sampling method is presented. In the case of inverter fed motor drive unlike line-driven motor drive, that make a lot of noise which can cause a wrong fault signals because of PWM(pulse width modulation) voltage. So, the current signals for fault diagnosis need very precise and high resolution information, which means this system demand additional hardware such as low pass filter, high resolution ADC system and so on to use fault diagnosis system. Therefore, the proposed over-sampling method is expected to contribute to low cost fault diagnosis system even though previous inverter fed motor drive without any additional hardware. In order to confirm the presented algorithms, various experiments for bearing faults are tested and the line current spectrum of each faulty situation using park transformation is compared with a FFT results.

  • PDF

Partial Discharge Signal Denoising using Adaptive Translation Invariant Wavelet Transform-Online Measurement

  • Maheswari, R.V.;Subburaj, P.;Vigneshwaran, B.;Iruthayarajan, M. Willjuice
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.695-706
    • /
    • 2014
  • Partial discharge (PD) measurements have emerged as a dominant investigative tool for condition monitoring of insulation in high voltage equipment. But the major problem behind them the PD signal is severely polluted by several noises like White noise, Random noise, Discrete Spectral Interferences (DSI) and the challenge lies with removing these noise from the onsite PD data effectively which leads to preserving the signal for feature extraction. Accordingly the paper is mainly classified into two parts. In first part the PD signal is artificially simulated and mixed with white noise. In second part the PD is measured then it is subjected to the proposed denoising techniques namely Translation Invariant Wavelet Transform (TIWT). The proposed TIWT method remains the edge of the original signal efficiently. Additionally TIWT based denoising is used to suppress Pseudo Gibbs phenomenon. In this paper an attempt has been made to review the methodology of denoising the PD signals and shows that the proposed denoising method results are better when compared to other wavelet-based approaches like Fast Fourier Transform (FFT), Discrete Wavelet Transform (DWT), by evaluating five different parameters like, Signal to noise ratio, Cross-correlation coefficient, Pulse amplitude distortion, Mean square error, Reduction in noise level.