• Title/Summary/Keyword: FEP

Search Result 104, Processing Time 0.025 seconds

On the Design of Optimal Response Time in Computer Terminal Networks

  • An Young-Ki
    • Journal of the military operations research society of Korea
    • /
    • v.2 no.1
    • /
    • pp.185-194
    • /
    • 1976
  • A terminal response time analysis for a general class of terminals-to-computer subsystem is presented in this paper. On the point of the front view, it should be considered for R.O.K. Military Defense to set up the communication network in order to facilitate for the currency of the information and the data communication system. The model used to study is based on the advanced data communications system in which terminals are connected to Terminal Control Units(TCU) that are in turn connected to local Front-End Processor(FEP). The line control procedures used to interface a TCU and an FEP may be half-duplex Binary Synchronous Communication(BSC), half-duplex Synchronous Data Link Control(SDLC), or full-duplex SLDC. This paper will contribute to facilitate the initial phase of system design and configuration for the Military Defense Communication Network System in future.

  • PDF

Development of Reference Scenarios Based on FEPs and Interaction Matrix for the Near-surface LILW Repository

  • Lee, Dong-Won;Kim, Chang-Lak;Park, Joo-Wan
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.539-546
    • /
    • 2001
  • Systematic procedure of developing radionuclide release scenarios was established based on FEP list and Interaction Matrix for near-surface LILW repository. FEPs were screened by experts'review in terms of domestic situation and combined into scenarios on the basis of Interaction Matrix analysis. Under the assumption of design scenario, The system domain was divided into three sections: Near-field, Far-field and Biosphere. Sub-scenarios for each section were developed, and then scenarios for entire system were built up with sub-scenarios of each section. Finally, sixteen design scenarios for near-surface repository were evaluated A reference scenario and other noteworthy scenarios were selected through experts'scenario screening.

  • PDF

A Study on the Charging and discharging current of corona charged Teflon-FEP film (코로나 대전된 Teflon-FEP의 충.방전 전류 특성에 관한 연구)

  • Cheong, Ki-Seok;Lee, Seung-Woo;Park, Kwang-Hyun;Lee, Deok-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.05a
    • /
    • pp.60-62
    • /
    • 1988
  • In this study, the characteristic of charging current which flows into the polymer by applying the corona discharge carriers on the polymer surface was measured, so as to investigate the phenomenon of charge injection and movement if injected charge on polymer. Also. the characteristics of discharge current which flows by shorting both sides of corona charged polymers were measured. Experimental results are as follows; The amount of charges injected by corona discharge vary according to the state of surface and the type of carriers, and then the charging current varies according to the properties of injected carriers.

  • PDF

Performance Trend Analysis For IN System Based On DB Updating Method (DB 수정방식에 따른 지능망 시스템의 성능추이분석)

  • 노용덕
    • Journal of the Korea Society for Simulation
    • /
    • v.11 no.2
    • /
    • pp.45-53
    • /
    • 2002
  • The main idea behind the Intelligent Networks(IN) concept is the separation of switching functionality from the service control, in order to meet various service requirements of subscribers and development of new services in time. In (N+1) type Intelligent Network with FEP-BEP framwork, each SCP-BEP system maintains its own subscibers' database respectively. In this case, DB updating operations at each SCP-BEP should be peformed concurrently such that DB updating method could affect the overall system performance. Moreover, it is not easy to predict the current system capacity to satisfy the future IN subscribers' service needs. In this paper, we discuss how much DB updating method affects the performance trends of (N+1) type Intelligent Network with FEP-BEP system by means of the simulation technique as the number of calls increase. The average turnaround time is used as a system performance measure.

  • PDF

Nutritional Status of 5th Grade School Children Residing in Low-Income Area of Pucheon City (부천시 저소득층 초등학교 5학년 어린들의 영양소 섭취 및 철분 영양 상태)

  • 손숙미;양정숙
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.3
    • /
    • pp.267-274
    • /
    • 1997
  • The purpose of this study was to determine the proportion of 5th grade school children with iron depletion or iron depleted anemia with simultaneously assessing their general nutritional status. The anthropometric measurements, nutrient intake, and biochemical status of iron were measured for 261 school children from 5th grade residing in low income area of Pucheon. The mean height and weight of male were 138.7cm and 33.6kg respectively and were significantly lower than those of female. Mean fat percent, triceps skinfolds thickness and arm circumference were 21.4$\%$, 13.7mm and 22.2cm for female and were significantly higher than 19.1$\%$, 11.4mm, 21.4cm of male respectively. The intake on vitamin A and calcium were 46.4$\%$ and 47.7$\%$ of RDA for male and 36.6$\%$ and 44.9$\%$ for male respectively. The energy intake, carbohydrate, thiamin, niacin, ascorbic acid of male were significantly higher than those of female respectively. The mean daily intake of iron were 7.5mg for male and 7.3mg for female and were not significantly different. The mean biochemical indices of iron nutritional status were not significantly different between male and female expect free erythrocyte protoporphyrin(FEP) and FEP : hemoglobin ratio. The proportion of male assessed by serum iron(<70$\mu\textrm{g}$/㎗), Hb($\%$), FEP(<70$\mu\textrm{g}$/㎗RBC) were 25.4$\%$, 8.4$\%$. 0.8$\%$, 1.8$\%$ respectively and 23.2$\%$, 8.4$\%$, 3.4$\%$, 1.0$\%$ for female respectively.

  • PDF

Algorithm for Predicting Functionally Equivalent Proteins from BLAST and HMMER Searches

  • Yu, Dong Su;Lee, Dae-Hee;Kim, Seong Keun;Lee, Choong Hoon;Song, Ju Yeon;Kong, Eun Bae;Kim, Jihyun F.
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.8
    • /
    • pp.1054-1058
    • /
    • 2012
  • In order to predict biologically significant attributes such as function from protein sequences, searching against large databases for homologous proteins is a common practice. In particular, BLAST and HMMER are widely used in a variety of biological fields. However, sequence-homologous proteins determined by BLAST and proteins having the same domains predicted by HMMER are not always functionally equivalent, even though their sequences are aligning with high similarity. Thus, accurate assignment of functionally equivalent proteins from aligned sequences remains a challenge in bioinformatics. We have developed the FEP-BH algorithm to predict functionally equivalent proteins from protein-protein pairs identified by BLAST and from protein-domain pairs predicted by HMMER. When examined against domain classes of the Pfam-A seed database, FEP-BH showed 71.53% accuracy, whereas BLAST and HMMER were 57.72% and 36.62%, respectively. We expect that the FEP-BH algorithm will be effective in predicting functionally equivalent proteins from BLAST and HMMER outputs and will also suit biologists who want to search out functionally equivalent proteins from among sequence-homologous proteins.

Technical Review on Risk Assessment Methodology for Carbon Marine Geological Storage Systems (이산화탄소 해양 지중저장 시스템에서의 누출 위해성 평가방법에 관한 기술적 검토)

  • Hwang, Jin-Hwan;Kang, Seong-Gil;Park, Young-Gyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.121-125
    • /
    • 2010
  • Carbon Capture and Storage (CCS) technology mitigates the emission amount of carbon dioxide into the atmosphere and can reduce green house effect which causes the climate change. Deep saline aquifer or obsolete oil/gas storage etc. in the marine geological structure are considered as the candidates for the storage. The injection and storage relating technology have been interested in the global society, however the adverse effect caused by leakage from the system failure. Even the safety level of the CCS is very high and there is almost no possibility to leak but, still the risk to marine ecosystem of the high concentrated carbon dioxide exposure is not verified. The present study introduces the system and environmental risk assessment methods. The feature, event and process approach can be a good starting point and we found the some possibility from the fault tree analysis for evaluation. From the FEP analysis, we drove the possible scenario which we need to concentrate on the construction and operation stages.

Pattern Analysis of Volume of Basal Ganglia Structures in Patients with First-Episode Psychosis (초발 정신병 환자에서 기저핵 구조물 부피의 패턴분석)

  • Min, Sally;Lee, Tae Young;Kwak, Yoobin;Kwon, Jun Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.25 no.2
    • /
    • pp.38-43
    • /
    • 2018
  • Objectives Dopamine dysregulation has been regarded as one of the core pathologies in patients with schizophrenia. Since dopamine synthesis capacity has found to be inconsistent in patients with schizophrenia, current classification of patients based on clinical symptoms cannot reflect the neurochemical heterogeneity of the disease. Here we performed new subtyping of patients with first-episode psychosis (FEP) through biotype-based cluster analysis. We specifically suggested basal ganglia structural changes as a biotype, which deeply involves in the dopaminergic circuit. Methods Forty FEP and 40 demographically matched healthy participants underwent 3T T1 MRI. Whole brain parcellation was conducted, and volumes of total 6 regions of basal ganglia have been extracted as features for cluster analysis. We used K-means clustering, and external validation was conducted with Positive and Negative Syndrome Scale (PANSS). Results K-means clustering divided 40 FEP subjects into 2 clusters. Cluster 1 (n = 25) showed substantial volume decrease in 4 regions of basal ganglia compared to Cluster 2 (n = 15). Cluster 1 showed higher positive scales of PANSS compared with Cluster 2 (F = 2.333, p = 0.025). Compared to healthy controls, Cluster 1 showed smaller volumes in 4 regions, whereas Cluster 2 showed larger volumes in 3 regions. Conclusions Two subgroups have been found by cluster analysis, which showed a distinct difference in volume patterns of basal ganglia structures and positive symptom severity. The result possibly reflects the neurobiological heterogeneity of schizophrenia. Thus, the current study supports the importance of paradigm shift toward biotype-based diagnosis, instead of phenotype, for future precision psychiatry.

  • PDF

Efficiency Calibration of HPGe Detector in Normal ana Coincidence Mode for the Determination of Prompt Gamma-ray (즉발감마선 측정을 위한 HPGe 검출기의 전계수 또는 동시계수모드에서의 광대역 계측효율 보정)

  • 송병철;박용준;지광용
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy(NIPS) system measures the prompt gamma-ray emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many element in either solid or liquid wastes. In this study, the full-energy-peak (FEP) efficiency calibration for a HPGe detector was constructed in the ${\gamma}$-ray energy range from 80 keV to 8 MeV, using $^{l33}$Ba and >TEX>$^{152}Eu$ RI sources and $ ^{35}Cl(n, ${\gamma}$)^{36}Cl$ thermal neutron captured reaction. The FEP efficiency curve for the higher energies using the $^{35}Cl(n, ${\gamma}$)^{36}Cl$ reaction was normalized with the curve obtained from the RI sources, since the accurate activity of its prompt ${\gamma}$-ray is unknown. The average thermal neutron flux was theoretically calculated using the FEP efficiency curve for the KCl standard solutions. The NIPS system equipped with a ${\gamma}$-${\gamma}$ coincidence setup with two n-type coaxial HPGe detectors was considered in order to reduce the interfering ${\gamma}$-ray background. The FEP efficiency curve for the ${\gamma}$-${\gamma}$ coincidence system was also obtained for full energy range. The performance of the normal and coincidence NIPS system was tested by comparing signal-to-noise ratio in each mode using the reference sample.e.

  • PDF

Dead Layer Thickness and Geometry Optimization of HPGe Detector Based on Monte Carlo Simulation

  • Suah Yu;Na Hye Kwon;Young Jae Jang;Byungchae Lee;Jihyun Yu;Dong-Wook Kim;Gyu-Seok Cho;Kum-Bae Kim;Geun Beom Kim;Cheol Ha Baek;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.129-135
    • /
    • 2022
  • Purpose: A full-energy-peak (FEP) efficiency correction is required through a Monte Carlo simulation for accurate radioactivity measurement, considering the geometrical characteristics of the detector and the sample. However, a relative deviation (RD) occurs between the measurement and calculation efficiencies when modeling using the data provided by the manufacturers due to the randomly generated dead layer. This study aims to optimize the structure of the detector by determining the dead layer thickness based on Monte Carlo simulation. Methods: The high-purity germanium (HPGe) detector used in this study was a coaxial p-type GC2518 model, and a certified reference material (CRM) was used to measure the FEP efficiency. Using the MC N-Particle Transport Code (MCNP) code, the FEP efficiency was calculated by increasing the thickness of the outer and inner dead layer in proportion to the thickness of the electrode. Results: As the thickness of the outer and inner dead layer increased by 0.1 mm and 0.1 ㎛, the efficiency difference decreased by 2.43% on average up to 1.0 mm and 1.0 ㎛ and increased by 1.86% thereafter. Therefore, the structure of the detector was optimized by determining 1.0 mm and 1.0 ㎛ as thickness of the dead layer. Conclusions: The effect of the dead layer on the FEP efficiency was evaluated, and an excellent agreement between the measured and calculated efficiencies was confirmed with RDs of less than 4%. It suggests that the optimized HPGe detector can be used to measure the accurate radioactivity using in dismantling and disposing medical linear accelerators.