• Title/Summary/Keyword: FDR sensor

Search Result 28, Processing Time 0.027 seconds

An Experimental Study on the Evaluation of Mortat Unit-Water Content by Powder Ratio Using Frequency Domain Reflectometry Sensor (고주파수분센서를 활용한 분체 비율별 모르타르 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Wi, Kwang-Woo;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.109-110
    • /
    • 2022
  • Currently, interest in the quality of concrete is increasing. Among the important factors for evaluating the quality of concrete, interest in unit-water content is also increasing. Currently, the air-meter method, the microwave oven drying method, the capacitance method, and the microwave penetration method are used to measure the unit-water content of concrete.. Among the above methods, except for the microwave method, the measurement method is complicated, portability is reduced, and economic efficiency is reduced. This research aims to measure a unit-water content by using a Frequency Domain Reflectometry(FDR) sensor that is economical, simple to measure, and portable among microwave methods. In addition, it is an experimental study to determine the accuracy of unit-water content using a single input residual model during deep learning to solve the limitations of the FDR sensor.

  • PDF

An Experimental Study on the Evaluation of Unit-Water Content of High Strength Concrete by Frequency Domain Reflectometry Sensor (고주파수분센서를 통한 고강도 콘크리트 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Yu, Seung-Hwan;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.173-174
    • /
    • 2023
  • In this study, unit-water content was measured using a frequency domain reflecometry(FDR) sensor that complements the problems of the existing unit-water content measurement method to evaluate the unit-water content affecting the workability, durability, and quality of high strength concrete. The experiment used the unit-water content of high strength concrete as a variable, and the accuracy and probability distribution of the unit-water content measured through deep learning were analyzed for the output value output through the FDR sensor. In the case of the unit-water content predicted by deep learning analysis, a high accuracy and high distribution of more than 93% were found within the error range of ± 10 kg/m3. In the future, research is needed to secure high reliability by utilizing data obtained through experiments with various variables.

  • PDF

Measuring Water Content Characteristics by Using Frequency Domain Reflectometry Sensor in Coconut Coir Substrate (FDR(Frequency Domain Reflectometry)센서를 이용한 코코넛 코이어 배지내 수분특성 측정)

  • Park, Sung Tae;Jung, Geum Hyang;Yoo, Hyung Joo;Choi, Eun-Young;Choi, Ki-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.23 no.2
    • /
    • pp.158-166
    • /
    • 2014
  • This experiment has investigated suitable methods to improve precision water content monitoring of coconut coir substrates to control irrigation by frequency domain reflectometry(FDR) sensors. Specifically, water content changes and variations were observed at different sensing distances and positions from the irrigation dripper location, and different spaces between the FDR sensors with or without noise filters. Commercial coconut coir substrates containing different ratios of dust and chips(10:0, 7:3, 5:5, 3:7) were used. On the upper side and the side of the substrates, a FDR sensor was used at 5, 10, 20, 30cm distances respectively from the irrigation dripper point, and water content was measured by time after the irrigation. In the glass beads, sensors were installed with or without noise filtering. Closer sensing distance had a higher water content increasing rate, regardless of different coir substrate ratios. There were no differencies of water content increasing rates in 10:0 and 3:7 substrates between the upper side and the side. Whereas, 7:3 and 5:5 substrates showed higher increasing rates on the upper side measurements. Substrates with higher ratios of chip(3:7) had lower increasing rates than others. And, with noise filters, the exatitude of measurement was improved because the variation and deviation were reduced. Therefore, in coconut coir with FDR sensors, an efficient water content measurment to control irrigations can be achieved by installing sensors closer to an irrigation point and upper side of substrates with noise filters.

Construction and estimation of soil moisture site with FDR and COSMIC-ray (SM-FC) sensors for calibration/validation of satellite-based and COSMIC-ray soil moisture products in Sungkyunkwan university, South Korea (위성 토양수분 데이터 및 COSMIC-ray 데이터 보정/검증을 위한 성균관대학교 내 FDR 센서 토양수분 측정 연구(SM-FC) 및 데이터 분석)

  • Kim, Hyunglok;Sunwoo, Wooyeon;Kim, Seongkyun;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.2
    • /
    • pp.133-144
    • /
    • 2016
  • In this study, Frequency Domain Reflectometry (FDR) and COSMIC-ray soil moisture (SM) stations were installed at Sungkyunkwan University in Suwon, South Korea. To provide reliable information about SM, soil property test, time series analysis of measured soil moisture, and comparison of measured SM with satellite-based SM product are conducted. In 2014, six FDR stations were set up for obtaining SM. Each of the stations had four FDR sensors with soil depth from 5 cm to 40 cm at 5~10 cm different intervals. The result showed that study region had heterogeneous soil layer properties such as sand and loamy sand. The measured SM data showed strong coupling with precipitation. Furthermore, they had a high correlation coefficient and a low root mean square deviation (RMSD) as compared to the satellite-based SM products. After verifying the accuracy of the data in 2014, four FDR stations and one COSMIC-ray station were additionally installed to establish the Soil Moisture site with FDR and COSMIC-ray, called SM-FC. COSMIC-ray-based SM had a high correlation coefficient of 0.95 compared with mean SM of FDR stations. From these results, the SM-FC will give a valuable insight for researchers into investigate satellite- and model-based SM validation study in South Korea.

Verification of TDR and FDR Sensors for Volumetric Soil Water Content Measurement in Sandy Loam Soil (사양토에서의 용적수분 함량 측정을 위한 TDR 및 FDR 센서의 검증)

  • Hur, Seung-Oh;Ha, Sang-Keun;Kim, Jeong-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.2
    • /
    • pp.110-116
    • /
    • 2009
  • This study was to verify and calibrate seven kinds of soil water sensors for volumetric soil water content(VSWC) measurement under field. Types of sensors were TDR (Time Domain Reflectometry) and FDR(Frequency Domain Reflectometry). Two kinds of TDR were TRIME(profile type), and Mini-TRASE(rod type). Five kinds of FDR were EasyAG, EnviroSCAN, PR-1(profile type), and WET-1(rod type). VSWC by TRIME and Mini-TRASE compared with VSWC by soil core showed the standard error of about 2.4%, and 1.4% which is the smallest value among all the sensors used in the experiment, respectively. The errors of EasyAG and EnviroSCAN analyzed with scaled frequency(SF) were about 2.6%, and 2.8% and those by 1 versus 1 correspondence were about 2.6%, and 2.6%, respectively. WET-1 showed about 2.0% of error, which is the smallest value among errors by FDR sensors. PR-1 with the error of about 4.7% should be hard for application in field. Therefore, users on soil water sensors have to take into consideration the errors of sensors revealed after the calibration for the correct measurement of VSWC in field. The rest except for PR-1 among the sensors could be used for VSWC measurement with 1.4~2.6% error.

A Study on the Determination of Dielectric Constant of Saturated Porous Media Using Frequency Domain Reflectometry System (Frequency Domain Reflectometry System을 이용한 포화 다공질매질의 유전율 측정을 위한 연구)

  • 김만일;정교철
    • The Journal of Engineering Geology
    • /
    • v.14 no.2
    • /
    • pp.179-187
    • /
    • 2004
  • This study conducted a laboratory work to determine the change of dielectric constant of saturated soil porous media, which is injecting EML to use Frequency Domain Reflectometry(FDR) system and length 7cm-length measurement sensor. It is purpose of study that estimate a movement path through pore of soil for an ethanol mixing liquid(EML) which have the same specific gravity of water at $20{\;}^{\circ}C$, and determine to a dielectric measuring range for the measurement sensor. As an outflow point of saturated soil column upper part recedes from an EML inject point in EML diffusion test, the diffusion extent of EML through pore of saturated soil was expanded. And results of ail EML flow experiment were measured the change of dielectric constant at all measurement sensors which are placed to constant interval at the same travel time for saturated soil column. Therefore, the displace process of water that exist in pore of saturated soil by EML injection is enough available and confirm together mobility through pores.

A Development of Dielectric Measurement System for Detecting Physical Parameters of Ground in Subsurface Dam (지하댐 지반 물성치 측정을 위한 유전율 측정 시스템 개발)

  • Kim Man-il;Jeong Gyo-Cheol;Park Chang-Kun
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.361-369
    • /
    • 2004
  • The authors designed a new technique to measure dielectric constant of a soil media by Frequency Domain Reflectometry (FDR) system and its measurement sensor probe with different length such as 7m, 10cm and 15cm for estimating the variations of dielectric constant. Measurement of dielectric constant of soil material is possible to measure an interference wave generated by between incidence wave and reflection wave which are detected to electro-magnetic wave through the directional coupler at the high frequency range,0.1 to 1.7GHz, by FDR system. The obtained experimental results verified that the technique is very promising for non-destructive and continuous soil volumetric water content measurement monitoring in a laboratory. The relationship between the soil volumetric water content and the dielectric constant of soil media (standard sand) was expressed by a single regression ewe independent of soil texture at a small experimental error. Also the derived regression curve coincided well with that obtained by Topp curve.

A Study on the Estimation of Physical Parameters of Unsaturated Porous Media in the Laboratory (불포화 다공질매질의 물성치 측정을 위한 실험적 연구)

  • 김만일
    • The Journal of Engineering Geology
    • /
    • v.14 no.2
    • /
    • pp.169-177
    • /
    • 2004
  • The permeation movements of groundwater recharge and contaminate materials receive a eat effect due to porosity and effective porosity of porous media which is composing underground consisted of saturation and unsaturated states. This study developed Frequency Domain Reflectometry(FDR) system and measurement sensor, and then carried out the laboratory experiments to measure effective porosity for unsaturated porous media. Also, I suggested dielectric mixing models(DMMs) which can calculate the effective porosity from relation of measured dielectric constants. In the experimental results the extent range of effective porosity of standard sand and river sand which are unsaturated soil sample were measured in about 65∼85 % for porosity. In relation of effective porosity and porosity, especially, effective porosity confirmed that displays decreasing a little tendency as porosity increases. This is because unsaturated soil did not reach in saturation enough by air of very small amount that exist in pore between soil particles.

An Experimental Study on the Accuracy of Concrete Unit-Water Content Using High-frequency Water Fraction Sensors (고주파수분센서를 이용한 콘크리트 단위수량 평가 정확도에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Yu, Seung-Hwan;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.61-62
    • /
    • 2022
  • The unit quantity is an important factor influencing the durability, workability, and quality of concrete. Methods for measuring the unit quantity include a high frequency heating method, a unit volume mass method, a capacitance method, and a microwave method. However, these methods have disadvantages of poor measurement method, time required, and accuracy, and a relatively experimental method compensating for these disadvantages was used to measure the unit quantity using a high frequency main sensor (FDR) capable of simple and fast measurement. In addition, the unit quantity was evaluated by analyzing the measurement data through deep learning.

  • PDF

Development of an Integrated Monitoring System for the Low and Intermediate Level Radioactive Waste Near-surface Disposal Facility (방사성폐기물 표층처분시설 통합 모니터링 시스템 개발)

  • Se-Ho Choi;HyunGoo Kang;MiJin Kwon;Jae-Chul Ha
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.359-367
    • /
    • 2023
  • In this study, the function and purpose of the disposal cover, which is an engineering barrier installed to isolate the disposal vault of the near-surface disposal facility for radioactive waste from natural/man-made intrusion, and the design details of the demonstration facility for performance verification were described. The Demonstration facility was designed in a partially divided form to secure the efficiency of measurement while being the same as the actual size of the surface disposal facility to be built in the Intermediate & low-level radioactive waste disposal site of the Korea Radioactive Waste Agency (KORAD). The instruments used for measurement consist of a multi-point thermometer, FDR (Frequency Domain Reflectometry) sensor, inclinometer, acoustic sensor, flow meter, and meteorological observer. It is used as input data for the monitoring system. The 3D monitoring system was composed of 5 layers using the e-government standard framework, and was developed based on 4 components: screen, control module, service module, and DBIO(DataBase Input Output) module, and connected them to system operation. The monitoring system can provide real-time information on physical changes in the demonstration facility through the collection, analysis, storage, and visualization processes.