• Title/Summary/Keyword: FDD system

Search Result 104, Processing Time 0.026 seconds

Analysis of Capacity Decrease Through Calculating Statistically the Amount of Interference From IMT-2000 TDD System to FDD System (IMT-2000 TDD시스템에서 FDD시스템으로의 통계적인 간섭량 계산을 통한 FDD 시스템의 용량 감소 분석)

  • Kim, Sung-Jin;Choi, Sang-Sung;Lee, Hyung-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.572-575
    • /
    • 2003
  • There is two System for IMT-2000 Service. one is FDD(Frequency Division Duplex), the other is TDD(Time Division Duplex) system. At the 1920MHz, they have common boundary in IMT-2000 frequency allocation of Korea. In this paper, The amount of Interference From TDD MS(Mobile Station) and BS(Base Station) to FDD BS is Analyzed for Investigation on capacity variation of FDD service by frequency separation. the result and methodology in this paper will be used basically for calculating the guard-band between FDD and TDD service in the future

  • PDF

Development of fault detection and diagnosis system for the heat source apparatus of building air-conditioning system (공조시스템의 열원기기에 대한 고장검출 및 진단 시스템 개발)

  • Han, Dong-Won;Park, Jong-Soo;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.30-35
    • /
    • 2008
  • This paper describes a fault detection and diagnosis (FDD) system developed for the heat source apparatus in building air-conditioning system. As HVAC&R systems in building become complex and instrumented with highly automated controllers, the processes and systems get more difficult for the operator to understand and detect the mal-functions. Poorly maintained, degraded, and improperly controlled equipment wastes an estimated 15% to 30% of energy used in commercial building. When operating a complex facility, FDD system is beneficial in equipment management to provide the operator with tools which can help in decision making for recovery from a failure of the system. Automated FDD for HVAC&R system has the potential to reduce energy and maintenance costs and improves comfort and reliability. Over the last decade there has been considerable research for developing FDD system for HVAC&R equipment. However, they are being made too much of a theoretical study, so only a small of FDD methods are deployed in the field. This study deduced an actual defect source for the heat source apparatus and suggested a low price FDD method which is ready to be deployed in the field.

  • PDF

Interference Resolving Radio Resource Allocation Scheme in a TDD-OFDMA/FDD-CDMA Hierarchical Over lay Cellular System

  • Lee, Yeonwoo;Kim, Kyung-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.7
    • /
    • pp.862-869
    • /
    • 2013
  • In order to support a cell-independent traffic asymmetry, the conventional TDD system cannot avoid crossed time slot (CTS) interference. Moreover, the TDD/FDD hierarchical overlay cellular systems is taken into account as a generally accepted cell model in a heterogeneous radio environment. In this paper, we propose an interference resolving radio resource allocation technique in a TDD-OFDMA cellular system that overlays a FDD-CDMA cell. In our proposed scheme, we exploit under-used FDD-CDMA uplink resource by TDD mobile abiding by a region based time slot(TS) allocation which in turn mitigates CTS interference considerably. It is demonstrated that combined with under-used resource utilization scheme based on mobile's location, the proposed technique can reduce CTS interference considerably and support the asymmetric traffic in TDD system.

The On-Line Diagnostic Test of Fault Diagnosis System for Air Handling Unit (공조설비용 고장진단시스템의 실시간 진단실험)

  • 소정훈;유승신;경남호;신기석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.787-795
    • /
    • 2001
  • An experimentation on the on-line fault detection and diagnosis(FDD) system has been performed with HVAC system in he experimental building constructed inside the large scale environmental chamber. Personal computer with a home-made FDD program by pattern recognition method utilizing artificial neural network was connected on-line via Ether-net TCP/IP to the supervisory control server for HVAC system. The FDD program monitored the HVAC system by 1 minuted interval. The results showed that he FDD program detected the sudden or abrupt faults such s those in fans, sensors and heater, etc.

  • PDF

On-Line Fault Diagnosis System using Neural Network (신경망을 이용한 실시간 고장 진단 시스템)

  • 김문성;유승선;소정훈;곽훈성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11C
    • /
    • pp.75-84
    • /
    • 2001
  • In this paper, we propose an on-line FDD(Fault Detection and Diagnosis) system based on the three layer feed-forward neural network which is trained by the back-propagation teaming algorithm. We implement the on-line fault detection and diagnosis system by Visual C++ and Visual Basic. The proposed FDD system is applied to an air handling unit in operation. Experimental results show the high performance of our system in the task of fault detection and diagnosis.

  • PDF

Model-based and wavelet-based fault detection and diagnosis for biomedical and manufacturing applications: Leading Towards Better Quality of Life

  • Kao, Imin;Li, Xiaolin;Tsai, Chia-Hung Dylan
    • Smart Structures and Systems
    • /
    • v.5 no.2
    • /
    • pp.153-171
    • /
    • 2009
  • In this paper, the analytical fault detection and diagnosis (FDD) is presented using model-based and signal-based methodology with wavelet analysis on signals obtained from sensors and sensor networks. In the model-based FDD, we present the modeling of contact interface found in soft materials, including the biomedical contacts. Fingerprint analysis and signal-based FDD are also presented with an experimental framework consisting of a mechanical pneumatic system typically found in manufacturing automation. This diagnosis system focuses on the signal-based approach which employs multi-resolution wavelet decomposition of various sensor signals such as pressure, flow rate, etc., to determine leak configuration. Pattern recognition technique and analytical vectorized maps are developed to diagnose an unknown leakage based on the established FDD information using the affine mapping. Experimental studies and analysis are presented to illustrate the FDD methodology. Both model-based and wavelet-based FDD applied in contact interface and manufacturing automation have implication towards better quality of life by applying theory and practice to understand how effective diagnosis can be made using intelligent FDD. As an illustration, a model-based contact surface technology an benefit the diabetes with the detection of abnormal contact patterns that may result in ulceration if not detected and treated in time, thus, improving the quality of life of the patients. Ultimately, effective diagnosis using FDD with wavelet analysis, whether it is employed in biomedical applications or manufacturing automation, can have impacts on improving our quality of life.

Adjacent Interference Analysis between M-WiMAX OFDMA/TDD and WCDMA FDD System in the 2.6 GHz Band Part II : Adjacent Interference Analysis with Smart Antenna in M-WiMAX System (2.6 GHz 대역에서 M-WiMAX OFDMA/TDD 시스템과 WCDMA FDD 시스템간의 상호 간섭 분석 Part II : Adjacent Interference Analysis with Smart Antenna in M-WiMAX System)

  • Wang, Yu-Peng;Ko, Sang-Jun;Chang, Kyung-Hi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6A
    • /
    • pp.588-599
    • /
    • 2007
  • This paper presents the coexistence issues between M-WiMAX TDD and WCDMA FDD systems. To improve the M-WiMAX system performance and to reduce the adjacent channel interference to WCDMA FDD system, transmit and receive beamforming techniques are applied in the base stations of M-WiMAX system. Furthermore, we propose an adjacent channel interference modeling methodology, which captures the effect of transmit beamforming on the adjacent channel interference. Besides, we verify the performance improvement in the uplink of WCDMA system due to the transmit beamforming in M-WiMAX downlink based on the proposed adjacent channel interference modeling methodology. We also verify the performance enhancement due to the receive beamforming in the uplink of M-WiMAX system through system level Monte Carlo simulations, considering random user position, the effect of shadowing and multi-path fading channel. Discussions on the gain of applying transmit and receive beamforming in M-WiMAX system comparing the case of SISO system are also included. Furthermore, we present the performance of cosited M-WiMAX and WCDMA systems, considering commercial deployment, additional channel filter at base stations and the effects of TxBF and RxBF.

Beamforming Based CSI Reference Signal Transmission for FDD Massive MIMO Systems (주파수 분할 방식의 거대 다중 안테나 시스템을 위한 빔형성 기반의 채널상태정보 기준신호 전송기술)

  • Hong, Jun-Ki;Jo, Han-Shin;Mun, Cheol;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.5
    • /
    • pp.520-530
    • /
    • 2016
  • Since FDD massive MIMO (multiple-input multiple-output) system deploys hundreds of transmit antennas at base station (BS) compared to conventional MIMO system, the overhead of transmitting channel state information reference signal (CSI-RS) increases proportionally to the number of transmit-antennas. To overcome these disadvantages, we proposed beamforming based CSI-RS transmission technique for FDD massive MIMO system which transmit CSI-RS by limited amount of downlink resources.

FEXT cancellation for high-speed local transmission over twisted pair wiring (동축 선로에서의 초고속 근거리 전송을 위한 FEXT 제거기)

  • 우정수;강규민;임기홍
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.8C
    • /
    • pp.782-791
    • /
    • 2002
  • This paper discusses a far-end crosstalk (FEXT) canceller for twisted-pair transmission. Many twisted-pair systems such as fiber-to-the-curb (FTTC), very high-speed digital subscriber line (VDSL), and high-speed LAN systems, use frequency-division duplexing (FDD) for duplex transmission. It is shown that the maximum reach of FDD twisted-pair system is limited by the performance of its upstream channel, which is located at higher frequencies than the downstream channel. In order to improve the performance of such FDD transceiver, FEXT cancellation is introduced for the channel at higher frequencies. A system arrangement and its blind start-up procedure are studied when the FEXT canceller and equalizer are jointly adapted to combat channel intersymbol interference (ISI), FEXT, and other additive noise. The initial convergence and the steady-state behavior of the proposed twisted-pair system without requiring transmission of an ideal training sequence are investigated. Measured characteristics as well as analytical model of the FEXT channel are used to estimate the time span needed for the FEXT canceller. It is also shown that the memory span for the FEXT canceller is almost independent of the channel, thus making our results useful for the twisted-pair system over all different channels.

Fault Location Diagnosis Technique of Photovoltaic Power Systems through Statistic Signal Process of its Output Power Deviation (출력편차의 통계학적 신호처리를 통한 태양광 발전 시스템의 고장 위치 진단 기술)

  • Cho, Hyun Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1545-1550
    • /
    • 2014
  • Fault detection and diagnosis (FDD) of photovoltaic (PV) power systems is one of significant techniques for reducing economic loss due to abnormality occurred in PV modules. This paper presents a new FDD method against PV power systems by using statistical comparison. This comparative approach includes deviation signals between the outputs of two neighboring PV modules. We first define a binary hypothesis testing under such deviation and make use of a generalized likelihood ratio testing (GLRT) theory to derive its FDD algorithm. Additionally, a recursive computational mechanism for our proposed FDD algorithm is presented for improving a computational effectiveness in practice. We carry out a real-time experiment to test reliability of the proposed FDD algorithm by utilizing a lab based PV test-bed system.