• Title/Summary/Keyword: F0 Range

Search Result 1,447, Processing Time 0.031 seconds

The Recent Outcomes after Repair of Tetralogy of Fallot Associated with Pulmonary Atresia and Major Aortopulmonary Collateral Arteries (폐동맥폐쇄와 주대동맥폐동맥부행혈관을 동반한 활로씨사징증 교정의 최근 결과)

  • Kim Jin-Hyun;Kim Woong-Han;Kim Dong-Jung;Jung Eui-Suk;Jeon Jae-Hyun;Min Sun-Kyung;Hong Jang-Mee;Lee Jeong-Ryul;Rho Joon-Ryuang;Kim Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.269-274
    • /
    • 2006
  • Background: Tetralogy of Fallot (TOF) with pulmonary atresia and major aortopulmonary collateral arteries (MAPCAS) is complex lesion with marked heterogeneity of pulmonary blood supply and arborization anomalies. Patients with TOF with PA and MAPCAS have traditionally required multiple staged unifocalization of pulmonary blood supply before undergoing complete repair. In this report, we describe recent change of strategy and the results in our institution. Material and Method: We established surgical stratagies: early correction, central mediastinal approach, initial RV-PA conduit interposition, and aggressive intervention. Between July 1998 and August 2004, 23 patients were surgically treated at our institution. We divided them into 3 groups by initial operation method; group I: one stage total correction, group II: RV-PA conduit and unifocalization, group III: RV-PA conduit interposition only. Result: Mean ages at initial operation in each group were $13.9{\pm}16.0$ months (group 1), $10.4{\pm}15.6$ months (group II), and $7.9{\pm}7.7$ months (group III). True pulmonary arteries were not present in f patient and the pulmonary arteries were confluent in 22 patients. The balloon angioplasty was done in average 1.3 times (range: $1{\sim}6$). There were 4 early deaths relating initial operation, and 1 late death due to incracranial hemorrhage after definitive repair. The operative mortalities of initial procedures in each group were 25.0% (1/4: group I), 20.0% (2/10: group II), and 12.2% (1/9: group III). The causes of operative mortality were hypoxia (2), low cardiac output (1) and sudden cardiac arrest (1). Definitive repair rates in each group were 75% (3/4) in group I, 20% (2/10, fenestration: 2) in group II, and 55.0% (5/9, fenestration: 1) in group III. Conclusion: In patients of TOF with PA and MAPCAS, RV-PA connection as a initial procedure could be performed with relatively low risk, and high rate of definitive repair can be obtained in the help of balloon pulmonary angioplasty. One stage RV-PA connection and unifocalization appeared to be successful in selected patients.

Major, Trace and Rare Earth Element Geochemistry, and Oxygen-Isotope Systematics of Illite/smectite in the Reindeer D-27 Well, Beaufort-Mackenzie Basin, Arctic Canada (카나다 보포트-맥켄지 분지의 일라이트/스멕타이트의 원소 지화학 및 산소동위원소 연구)

  • Ko, J.;Hesse, R.;Longstaffe, F.J.
    • Economic and Environmental Geology
    • /
    • v.28 no.4
    • /
    • pp.351-367
    • /
    • 1995
  • The elemental geochemistry and oxygen isotopes of illite/smectite (I/S) have been studied in relationship to the mineralogical trend in the Reindeer D-27 well, Beaufort-Mackenzie Basin. The increase in concentrations of $K_2O$, Rb and rare earth elements (REE), the decrease in concentrations of tetrahedral elements such as Mg, Ti, Sc, Zn and Zr, and the increase in concentrations of tetrahedral elements such as Be and V can be related to I/S compositions that vary systematically with depth. Layer formulae of S- and I-layers are estimated as $[Al_{1.57}Fe_{.19}Mg_{.31}Ti_{.07}][Si_{3.84}Al_{.16}]O_{10}(OH)_2$ and $[Al_{1.84}Mg_{.16}][Si_{3.33}Al_{.67}]O_{10}(OH)_2$, respectively. The mobilization of REE appears to occur during illitization. The increase in concentrations of REE, especially La and Ce, with depth is probably linked to incorporation of ions with high valency (e.g. $V^{5+}$) in tetrahedral sites. The excess valency due to V is partly counter-balanced by ions with low valency (e.g. $Be^{2+}$) and, in turn, the local valency deficiency caused by $Be^{2+}$ could be compensated by high-charge interlayer cations such as REE (+3). ${\delta}^{18}O$ values of I/S range from 2.91 to 15.72‰ (SMOW), and increase with depth, contrasting to trends observed in the Gulf Coast and elsewhere. The increase in ${\delta}^{18}O$ of I/S results from the rapid increase in ${\delta}^{18}O$ of pore water that overcomes the decrease in temperature-dependent fractionation values with increasing burial depth (${\delta}^{18}O_{pore\;water}>-d{\Delta}/_{I/S-water};\;d{\delta}^{18}O_{I/S}>0$). Calculated ${\delta}^{18}O$ values of pore water in equilibrium with I/S suggest that the original water was probably meteoric water. The stratification of pore water is postulated from the presence of an isotopically light interval, about 450m thick. The depth range of the isotopically light zone overlaps, but does not coincide with the interval of lowered I-content and $K_2O$ concentrations, suggesting that oxygens may have been exchanged independently of mineralogical and geochemical reactions.

  • PDF

Clinical characteristics and courses of congenital muscular torticollis (선천성 근육성 사경의 임상적 특징과 경과)

  • Choi, Kyong Eun;Lee, Hee Chul;Youn, So Young;Chun, Jung Mi;Shin, Son Moon;Han, Byung Hee;Lee, Yong Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.11
    • /
    • pp.1273-1278
    • /
    • 2009
  • Purpose:Congenital muscular torticollis (CMT), a common musculoskeletal disorder in infants, is characterized by the rotation and flexion deformity of the neck caused by sternocleidomastoid muscle shortening. We investigated the clinical courses and perinatal risk factors of CMT. Methods:Less than 6-month-old patients (98; M:F = 60:38) diagnosed with CMT between February 2007 and August 2008 were classified into 2 clinical subgroups, namely, SMT (sternocleidomastoid tumor) and POST (postural torticollis). All the patients were physically and neurologically examined prospectively and their cervical X-rays and ultrasonographies were obtained. Their medical histories about perinatal problems were recorded. Of the 98 patients, 45 with normal range of motion were taught passive physical exercises and 43 were referred to the Department of Rehabilitation for undergoing manual stretching therapy. Results:The mean age at initial assessment was 2.2 months (SMT: $1.4{\pm}1.0$, POST: $2.7{\pm}1.6$). SMT presented earlier than POST. All ophthalmologic examinations and cervical X-rays were normal. SMT was associated with higher incidence of caput succedaneum and cephalhematoma. POST was highly associated with plagiocephaly. Mean duration of rehabilitative physical therapy was 3.7 months (SMT: $4.6{\pm}2.5$, POST: $2.6{\pm}1.9$). POST resolved earlier than SMT. Of the 88 patients with follow-up, 87 had total resolution and only 1 had residual torticollis. Conclusion:All the patients received early treatment with passive stretching exercises. CMT was associated with perinatal problems and had various risk factors such as obstetrical problems.

Forest Community Structure of Mt. Bukhan Area (북한산 지역의 삼림군집구조에 관한 연구)

  • 박인협;이경재;조재창
    • Korean Journal of Environment and Ecology
    • /
    • v.1 no.1
    • /
    • pp.1-23
    • /
    • 1987
  • To investigate the forest structure of Mt. Bukhan. ranging from Seoul to Kyongkido, twenty plots were set up by the vegetation physiognomy and vegetation analysis was carried out. According to the leading dominant tree species in canopy stratum, forest communities were classified into three large groups of natural forest communities, semi-natural forest communities and artificial forest communities, and each of them covered 82.64, 7.03, and 5.71% of Mt. Bukhan area, respectively. Pure or mixed natural forest communities of Pinus densiflora and Quercus mongolica were major forest communities and covered 70.8% of Mt. Bukhan area. The important planted tree species were Robinia pseudoacacia, Pinus rigida, and Alnus birsuta and they were mainly planted at the southern slope and roadside. The degree of human disturbance of vegetation of 8, 7, and 6 area covered 82.64, 0, and 12.74%, respectively. According to forest dimensions, most of forest communities were young aged forests of which mean DBH was 20cm and canopy height below 10m. However, a few mature forest communities of Pinus densiflora or Quercus mongolica were found in the small area. The range of Shannon's species diversity of major natural forest communities, pure or mixed forest communities of Pinus densiflora and Quercus mongolica was 1.085~1.242. According to stand dynamic analysis by DBH class distribution, the present Quercus mongolica communities arid Robinia pseudoacacia communities may last long their present forest structure and most of other communities may be succeeded to Quercus mongolica communities, however, a few communities invaded by Robinia pseudoacacia and Quercus aliena-Quercus acutissima communities may be succeeded to Robinia pseudoacacia communities and Quercus aliena communities, respectively. DCA was the most effective method of this study. DCA ordination were showed that successional trends of tree species seem to be from Pinus densiflora through Quercus serrata. Prunus sargrntii. Sorbus alnifolia to Q. mongolica. Fraxinus mandsburica, F. rhynchophylla in the upper layer and from Zanthoxylum schinifolium, Lespedeza crytobotrya trough Rhus trichocarpa. Rh. verniciflua. Rhododendron mucronulatum. Rh. schlippenbachii to Acer pseudo-sieboldianus. Magnolia sieboldii, Euonymus sieboldianus.

  • PDF

Effect of Acrylic Acid on the Physical Properties of UV-cured Coating Films for Metal Coating (금속코팅용 광경화 코팅필름의 물성에 대한 아크릴산(Acrylic acid)의 영향)

  • Seo, Jong-Chul;Choi, Jun-Suk;Jang, Eui-Sung;Seo, Kwang-Won;Han, Hak-Soo
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.75-82
    • /
    • 2011
  • Five different composition UV-cured poly(urethane acrylate-co-acrylic acid) (PU-co-AA) films have been prepared by reacting isophorone diisocyanate(IPDI), polycaprolactone triol(PCLT), 2-hydroxyethyl acrylate(HEA), and different weight ratio trimethylolpropane triacrylate(TMPTA) and acrylic acid(AA) as diluents, and characterized using a Fourier transform infrared spectroscopy(FT-IR). The adhesion properties onto the stainless steel, morphology, mechanical hardness, and electrical property of UV-cured PU-co-AA films were investigated as a function of acrylic acid(AA) content. All the PU-co-AA films are structure-less and the molecular ordering and packing density decreased with increasing content of AA due to the flexible structure and -COOH side chains in AA. The crosscut test showed that PU-co-AA films without AA and with low content of AA showed 0% adhesion(0B) and the adhesion of PU-co-AA films in the range of 40-50% AA increased dramatically as the content of AA increases. The pull-off measurements showed that the adhesion force of PU-co-AA films to stainless steel substrate varied from 6 to 31 kgf /$cm^2$ and increased linearly with increasing AA content. The mechanical hardness also decreased as the content of AA increases. This may come from relatively linear and flexible structure in AA and low crystallinity in PU-co-AA films with higher content of AA. The higher AA-containing PU-co-AA films showed higher dielectric constant due to the increase of polarization by introducing AA monomer. In conclusion, the physical properties of UV-cured PU-co-AA films are strongly dependent upon the content of AA and the incorporation of AA in polyurethane acrylate is very useful way to increase the adhesion strength of UV-curable polymers on the stainless steel substrate.

EFFECT OF ROTATIONAL SPEED OF PROTAPERTM ROTARY FILE ON THE CHANCE OF ROOT CANAL CONFIGURATION (ProTaperTM로 근관성형시 회전 속도 변화가 근관형태에 미치는 영향)

  • Seo, Min-Chul;Jeon, Yoon-Jeong;Kang, In-Chol;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.179-185
    • /
    • 2006
  • This study was conducted to evaluate canal configuration after shaping by $ProTaper^{TM}$ with various rotational speed in J-shaped simulated resin canals. Forty simulated root canals were divided into 4 groups, and instrumented using by $ProTaper^{TM}$ at the rotational speed of 250, 300, 350 and 400 rpm. Pre-instrumented and post-instrumented images were taken by a scanner and those were superimposed. Outer canal width, inner canal width, total canal width, and amount of transportation from original axis were measured at 1, 2, 3, 4, 5, 6, 7 and 8 mm from apex. Instrumentation time, instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA followed by Scheffe's test. The results were as follows 1. Regardless of rotational speed, at the $1{\sim}2mm$ from the apex, axis of canal was transported to outer side of a curvature, and at 3~6 mm from the apex, to inner side of a curvature. Amounts of transportation from original axis were not sienifcantly different among experimental groups except at 5 and 6 mm from the apex. 2. Instrumentation time of 350 and 400 rpm was significantly less than that of 250 and 300 rpm (p<0.01). In conclusion the rotational speed of $ProTaper^{TM}$ files in the range of $250{\sim}400rpm$ does not affect the change of canal configuration, and high rotational speed reduces the instrumentation time. However appearance of separation and distortion of Ni-Ti rotary files can occur in high rotational speed.

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Bioequivalence of SCD Zaltoprofen Tablet to Soleton® Tablet (Zaltoprofen 80 mg) (솔레톤 정(잘토프로펜 80 mg)에 대한 삼천당잘토프로펜 정의 생물학적동등성)

  • Kang, Hyun-Ah;Park, Sun-Ae;Kim, Dong-Ho;Kim, Hwan-Ho;Yun, Hwa;Kim, Kyng-Ran;Yoo, Hee-Doo;Park, Eun-Ja;Cho, Hye-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.209-215
    • /
    • 2006
  • Zaltoprofen, (2-(10,11-dihydro-10-oxodibenzo[b,f]thiepin-2-yl)propionic acid) is an NSAID with powerful anti-inflammatory effects as well as an analgesic action on inflammatory pain. The purpose of the present study was to evaluate the bioequivalence of two zaltoprofen tablets, $Soleton^{\circledR}$ (CJ Corp.) and SCD Zaltoprofen (Samchundang Pharmaceutical Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of zaltoprofen from the two zatoprofen formulations in vitro was tested using KP Vlll Apparatus ll method with various dissolution media. Twenty six healthy male subjects, $23.2{\pm}2.26$ years in age and$64.7{\pm}8.08$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After a single tablet containing 80 mg as zaltoprofen was orally administered, blood samples were taken at predetermined time intervals and the concentrations of zaltoprofen in serum were determined using HPLC with UV detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Soleton^{\circledR}$ were 6.33, 5.91 and 17.7% for $AUC_t$, $C_{max}$ and untransformed $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g.,log $1.01{\sim}1og\;1.11$ and log $0.928{\sim}1og\;1.18$ for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating SCD Zaltoprofen tablet was bioequivalent to $Soleton^{\circledR}$ tablet.

Ore minerals and Genetic Environments from the Baekun Gold-silver Deposit, Republic of Korea (백운 금-은광상에서 산출되는 광석광물과 생성환경)

  • Yoo, Bong-Chul;Lee, Hyun-Koo;Kim, Ki-Jung
    • Economic and Environmental Geology
    • /
    • v.39 no.1 s.176
    • /
    • pp.9-25
    • /
    • 2006
  • Baekun gold-silver deposit is an epithermal quartz vein that is filling the fault zone within Triassic or Jurassic foliated granodiorite. Mineralization is associated with fault-breccia zones and can be divided into two stages. Stage I which can be subdivided early and late depositional stages is main ore mineralization and stage II is barren. Early stage I is associated with wallrock alteration and the formation of sulfides such as arsenopyrite, pyrite, pyrrhotite, sphalerite, marcasite, chalcopyrite, stannite, galena. Late stage I is characterized by Au-Ag mineralization such as electrum, Ag-bearing tetrahedrite, stephanite, boulangerite, pyrargrite, argentite, schirmerite, native silver, Ag-Te-Sn-S system, Ag-Cu-S system, pyrite, chalcopyrite and galena. Fluid inclusion data indicate that homogenization temperatures and salinity of stage I range from $171.6^{\circ}C\;to\;360.8^{\circ}C\;and\;from\;0.5\;to\;10.2\;wt.\%\;eq.$ NaCl, respectively. It suggest that ore forming fluids were cooled and diluted with the mixing of meteoric water. Also, Temperature (early stage I: $236\~>380^{\circ}C,\;$ late stage $I: <197\~272^{\circ}C$) and sulfur fugacity (early stage $I:\;10^{-7.8}$ a atm., late stage I: $10^{-14.2}\~10^{-l6}atm$.) deduced mineral assemblages from stage 1 decrease with paragenetic sequence. Sulfur ($2.4\~6.1\%_{\circ}$(early stage $I=3.4\~5.3\%_{\circ},\;late\;stage\;I=2.4\~6.1\%_{\circ}$)), oxygen ($4.5\~8.8\%_{\circ}$(quartz: early stage $I=6.3\~8.8\%_{\circ}$, late stage $I=4.5\~5.6\%_{\circ}$)), hydrogen ($-96\~-70\%_{\circ}$ (quartz: early stage $I=-96\~-70\%_{\circ},\;late\;stage\;f=-78\~-74\%_{\circ},\;calcite:\;late\;stage\;I=-87\~-76\%_{\circ}$)) and carbon ($-6.8\~-4.6\%_{\circ}$ (calcite: late stage I)) isotope compositions indicated that hydrothermal fluids may be magmaticorigin with some degree of mixing of another meteoric water for paragenetic time.

Comparison of Urine Iodine/Creatinine ratio between Patients following Stringent and Less Stringent Low Iodine Diet for Radioiodine Remnant Ablation of Thyroid Cancer (갑상선암의 방사성요오드치료를 위한 저요오드식이 방법 차이에 따른 소변 중 요오드/크레아티닌 비의 비교)

  • Roh, Jee-Ho;Kim, Byung-Il;Ha, Ji-Su;Chang, Sei-Joong;Shin, Hye-Young;Choi, Joon-Hyuk;Kim, Do-Min;Kim, Chong-Soon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.322-326
    • /
    • 2006
  • A low iodine diet (LID) for $1{\sim}2$ weeks is recommended for patients who undergoing radioiodine remnant ablation. However, the LID educations for patients are different among centers because there is no concrete recommendation for protocol of LID. In this investigation, we compared two representative types of LID protocols performed in several centers in Korea using urine iodine to creatinine ratio (urine I/Cr). Methods: From 2006, April to June, patients referred to our center for radioiodine remnant ablation of thyroid cancer from several local hospitals which had different LID protocols were included. We divided into two groups, stringent LID for 1week and less stringent LID for 2 weeks, then measured their urine I/Cr ratio with spot urine when patients were admitted to the hospital. Results: Total 27 patients were included in this investigation (M:F=1:26; 13 in one-week stringent LID; 14 in two-week less stringent LID. Average of urine I/Cr ratio was $127.87{\pm}78.52{\mu}g/g$ in stringent LID for 1 week, and $289.75{\pm}188.24{\mu}g/g$ in less stringent LID for 2 weeks. It was significantly lower in stringent LID for 1 week group (p=0.008). The number of patients whose urine I/Cr ratios were below $100{\mu}g/g$ was 6 of 13 in stringent LID for 1 week group, and 3 of 14 in less stringent LID for 2 weeks group. Conclusion: Stringent LID for 1 week resulted in better urinary I/Cr ratio in our investigation compared with the other protocol. However it still resulted in plenty of inadequate range of I/Cr ratio, so more stringent protocol such as stringent LID for 2 weeks is expected more desirable.