• Title/Summary/Keyword: F.V.M.

Search Result 1,371, Processing Time 0.026 seconds

A CLASS OF MULTIVALENT FUNCTIONS WITH NEGATIVE COEFFICIENTS DEFINED BY CONVOLUTION

  • Ali Rosihan M.;Khan M. Hussain;Ravichandran V.;Subramanian K.G.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.43 no.1
    • /
    • pp.179-188
    • /
    • 2006
  • For a given p-valent analytic function g with positive coefficients in the open unit disk $\Delta$, we study a class of functions $f(z) = z^p - \sum\limits{_{n=m}}{^\infty} a_nz^n(a_n{\geq}0)$ satisfying $$\frac 1 {p}{\Re}\;(\frac {z(f*g)'(z)} {(f*g)(z)})\;>\;\alpha\;(0{\leq}\;\alpha\;<\;1;z{\in}{\Delta})$$ Coefficient inequalities, distortion and covering theorems, as well as closure theorems are determined. The results obtained extend several known results as special cases.

Physiological Characteristics and Morphological Changes of Chinese Cabbage (Brassica rapa L. ssp. campestris) to Potassium Toxicity (칼륨 독성에 의한 배추의 생리적 특성과 형태적 변화)

  • Lee, Taek-Jong;Luitel, Binod Prasad;Heo, Kweon;Choi, Bong-Jun;Kang, Won-Hee
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.311-319
    • /
    • 2011
  • Overusing chemical fertilizers involves potassium accumulation in the soil, which can become a toxicity problem in agriculture. This study was conducted to investigate the effect of potassium (K) treatment on growth, physiological characteristics, and morphological changes using Chinese cabbage (Brassica rapa L. ssp. campestris). With high (600 mM) K treatment, the plant growth traits of leaf length, leaf area, and fresh and dry weight of shoots and roots decreased, whereas chlorophyll content increased. As the concentration of K increasing, total N, P, and K increased in leaves, but concentrations of Ca, Mg, and Na decreased. However, Mn, Fe and Zn contents were highest in 100 mM K treatment. Chlorophyll a, b, and carotenoids increased with increasing K concentration. Maximum photochemical efficiency ($F_v/F_m$) was not significant in the all treatments, whereas $CO_2$ assimilation decreased with increasing K level due to stomatal degradation. Total free amino acids increased with the 10 and 100 mM K but decreased at 600 mM K treatments. Therefore, the growth and physiological characteristics of Chinese cabbage ascertained that tolerance up to 100 mM K when grown with nutrient solution in pot culture.

The Effects of Diagnostic Radiology Image on Radiopharmaceutical Testing (방사성의약품 검사 시 진단(CT)영상에 미치는 영향)

  • Lee, Eun-Hye;Lee, Ye-Seul;Kim, Gha-Jung;Choi, Jun-Gu
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.113-117
    • /
    • 2010
  • This research attempts to qualitatively evaluate the intensity change by radiopharmaceuticals and obtain computed tomography using phantom injected with various nuclide. Cylindrical phantom is used for comparing and analysing the effect on diagnosis image during radiopharmaceuticals inspection. Inside of the phantom, water is injected and computed tomography image is scanned. During nuclear medicine invitro, frequently used radiopharmaceuticals, $^{99m}TcO_4$ 20 mCi and $^{18}F$ 14 mCi, is diluted in the water phantom and scanned in the same method. Traverse image obtained by CT scan is divided into six traverse image in the same slice of each scanned image. CT-number(HU) value of 10 measuring point is measured in 2 cm interval based on the center of the phantom. Measured HU value, based on the water phantom, is compared with the image after injecting $^{99m}TcO_4$ and $^{18}F$. Average scale of water is 2.8~1.6 HU, $^{99m}TcO_4$ is 3.0~1.6 HU and $^{18}F$ is 1.2~0 HU. Average of water is $2.3{\pm}0.17$ HU, $^{99m}TcO_4$ is $2.2{\pm}0.85$ HU and F-18 is $0.7{\pm}0.95$ HU. Based on water, reduced value of about 0.1 HU and about 0.5 HU is acquired from $^{99m}TcO_4$ and F-18. Radionuclide used in nuclear medicine inspection utilizes 100~200 KeV energy and obtains image through scintillation camera and PET-CT utilizes 511 KeV positron annihilation energy to obtain image. What we learned from this research is that gamma rays from these energies used in CT scan for diagnosis purpose or radioactive therapy plan can change the intensity of the image. The nuclear medicine inspection for reducing the effect of emitted gamma ray diagnosis image should be obtained after a period of time considering half-life which would be reduced distortion or changed in image.

  • PDF

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

A Design and Implementation of 4×10 Gb/s Transimpedance Amplifiers (TIA) Array for TWDM-PON (TWDM-PON 응용을 위한 4×10 Gb/s Transimpedance Amplifier 어레이 설계 및 구현)

  • Yang, Choong-Reol;Lee, Kang-Yoon;Lee, Sang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.7
    • /
    • pp.440-448
    • /
    • 2014
  • A $4{\times}10$ Gb/s Transimpedance Amplifier (TIA) array is implemented in $0.13{\mu}m$ CMOS process technology, which will be used in the receiver of TWDM-PON system. A technology for bandwidth enhancement of a given $4{\times}10$ Gb/s TIA presented under inductor peaking technology and a single 1.2V power supply based low voltage design technology. It achieves 3 dB bandwidth of 7 GHz in the presence of a 0.5 pF photodiode capacitance. The trans-resistance gain is $50dB{\Omega}$, while 48 mW/ 1channel from a 1.2 V supply. The input sensitivity of the TIA is -27 dBm. The chip size is $1.9mm{\times}2.2mm$.

Refinement of the Structure of p-Dimethylaminobenzaldehyde 4-(p-Ethoxyphenyl) Thiosemicarbazone (p-Dimethylaminobenzaldehyde 4-(p-Ethoxyphenyl) Thiosemicarbazone구조의 정밀화)

  • Seo, Il-Hwan;Seo, Chu-Myeong;Park, Yeong-Ja
    • Korean Journal of Crystallography
    • /
    • v.2 no.1
    • /
    • pp.12-16
    • /
    • 1991
  • C18H22N4OS, Mr=342.47, monoclinic, P2₁/c,a=11.802(2), b=31.962(2), c=9.829(2)A, β=100.12(1)˚, V=3694.8A3,F(000)=1472, Z=8, Dx=1.246 Mg m-3, Dm=1.17Mg m-3,λ=0.71073 A, μ=0.15mm-1, T=294 K. final R=0.0856 for 3718 observed reflection (Fo>3σ(Fo)) There are two molecules in an asymmetric unit and a major difference between these molecules is in the C(9)-N(1)-C(6)-C(7) torsion angles [58.8(8)˚and 1(1)˚]. Both molecules have intramolecular N(1)-H(10)'N(3) hydrogen bonds [ 2.613(7) and 2.566(7) A] and assume V-shaped conformation with N(2) atoms at the verices. The two independent molecules are linked by the two N(2)-H(11)'S' hydrogen bonds[3.367(5) A and 3.421(4)A] and the dimergen are held together by van der Waals forces.

  • PDF

Fabrication of a Thin and Flexible Polyaniline Electrode for High-performance Planar Supercapacitors (고성능 평면 슈퍼커패시터를 위한 얇고 유연한 폴리아닐린 전극 제작)

  • Son, Seon Gyu;Kim, Seo Jin;Shin, Junho;Ryu, Taegon;Jeong, Jae-Min;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.403-408
    • /
    • 2021
  • In this study, a thin and flexible planar supercapacitor (PSC) was fabricated by coating polyaniline (PANI) on a screen-printed carbon electrode. Carbon ink was coated onto the flexible polyethylene terephthalate using a screen-printing method; subsequently, a thin film of PANI was coated onto the carbon surface using a dilute polymerization method. A thin flexible PANI electrode in an interdigitated structure was assembled with a polymer gel electrolyte that resulted in planar-shaped supercapacitor (PSC) devices. The as-obtained PANI/PSC was very thin and flexible, exhibiting a high areal capacitance of 409 µF/cm was obtained at a rate of 10 mV/s. This capacitance retains 46% of its original value at 500 mV/s. The flexible PANI/PSC exhibited an excellent capacitance retention of 82% even under bent states of 180° and 100 repetitive bent cycles.

A Study on High Performance Lateral Super Barrier Rectifier for Integration in BCD (Bipolar CMOS DMOS) Platform (BCD Platform과의 집적화에 적합한 고성능 Lateral Super Barrier Rectifier의 연구)

  • Kim, Duck-Soo;Lee, Hi-Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.371-374
    • /
    • 2015
  • This paper suggests a high performance lateral super barrier rectifier (Lateral SBR) device which has the advantages of both Schottky diode and pn junction, that is, low forward voltage and low leakage current, respectively. Advantage of the proposed lateral SBR is that it can be easily implemented and integrated in current BCD platform. As a result of simulation using TCAD, BVdss = 48 V, $V_F=0.38V$ @ $I_F=35mA$, T_j = $150^{\circ}C$ were obtained with very low leakage current characteristic of 3.25 uA.

Dynamic Characteristics of LIM controlled by constant V/f (V/f일정제어로 제어되는 LIM의 동특성)

  • Jang, S.M.;Jeong, H.G.;Kim, B.S.;Park, Y.T.;Jeong, Y.H.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.50-52
    • /
    • 1995
  • This paper deals with the dynamic characteristics of LIM which is controlled by constant V/f ratio and the characteristics of the Inverter acted as interface between the utility power system and LIM. Though open-loop control method is less reliable than closed-loop control method, it's commonly used because it is simple and cheap. This paper shows the consideration for dynamic characteristics of LIM under open-loop control and for Inverter.

  • PDF

Measurement of Al Concentration in Liquid Zinc by E.M.F Method with $CaF_2$ ($CaF_2$ 기전력법에 의한 용융아연 중 알루미늄 농도의 측정)

  • Park Jin Sung;Kim Hang Soo;Jung Woo-Gwang;Katayama I.;Kim Jong Sang
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.204-210
    • /
    • 2000
  • The control of dissolved aluminum concentration in the hot dip zinc galvanizing bath is greatly important in producing galvannealed steel sheets. The purpose of present study is to provide basic data for measurement of the aluminum concentration in site in hot dip zinc bath at the temperature of $460^{\circ}C\~500^{\circ}C$ using $CaF_2$ solid electrolyte sensor with three kinds of reference electrode. Good workability and stability of the sensor were confirmed with the $Bi+BiF_3$ reference electrode from the emf measurement. In order to measure the aluminum concentration in Zn-Al bath, the galvanic cell of fluorine ion was constructed with $CaF_2$ solid electrolyte as follows; $$(-)W|Zn-Al,\;AlF_3|CaF_2|Bi,BiF_3|W(+)$$. The emf measurement was made at the temperature of $460\pm10^{\circ}C$ in the Zn-Al bath. The following correlationship between aluminum concentration and emf was obtained by the least square regression analysis; $$E/mV=56.795log[\%Al]+1881.7\;R=0.9704$$,$$0.026wt\%{\leq}[\%Al]{\leq}0.984wt\%$$