• Title/Summary/Keyword: F-K 분석

Search Result 3,727, Processing Time 0.029 seconds

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.

Estimation of the Fundamental Matrix using a Non-linear Minimization Technique and Its Accuracy Analysis (비선형 최소화에 의한 F행렬 추정 및 정확도 분석)

  • Eom, Seong-Hun;Lee, Jong-Su
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.6
    • /
    • pp.657-664
    • /
    • 2001
  • It is possible to extract a 3D models from its multiple views using the self-calibration. Though it is possible to construct 3D models of objects from their multiple views, accuracy of 3D models depends on the fundamental matrix estimated between two views. In this paper, we show the fundamental matrix accuracy can be improved by taking a non-linear minimization technique. Furthermore, the corresponding points which are completely mismatches or have greater discrepancy errors in their locations, reduce the fundamental matrix accuracy. Thus, applying the Monte Carlo technique and the non-linear minimization Levenberg-Marquardt method to remove the outliers, we can estimate the fundamental matrix with the higher accuracy.

  • PDF

Diagnosis and Evaluation of Humanities Therapy: The Phonetic Analysis of Speech Rates and Fundamental Frequency According to Preferred Sensation Type (인문치료의 진단 및 평가: 감각유형에 따른 말속도와 기본주파수의 실험음성학적 분석)

  • Lee, Chan-Jong;Heo, Yun-Ju
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.4
    • /
    • pp.231-237
    • /
    • 2011
  • The purpose of this study is to examine the correlation between the preferred sensation type and speech sounds, especially on $F_0$ and the speech rates. Data for the sensation types and speech sounds were collected from 36 undergraduate and graduate students (17 male, 19 female). Subjects were asked to read a given text (400 syllables), describe a drawing, and give answers to some questions. We measured speakers' $F_0$ and speech rates. The results show that type V (Visual) has the correlation with the speech rates when type D (Digital) was ruled out, and type A (Auditory) has the correlation with the speech rates when type D was included. Furthermore, the analysis of the mean values of V, A, K (Visual, Auditory, Kinethetic) indicates that type V is characterized with faster speech rates and higher $F_0$ in all parts except for interview and the same is true for that of V, A, K, D (Visual, Auditory, Kinethetic, Digital) in all parts. In conclusion, this study proved that the preferred sensation type has the correlation with $F_0$ and speech rates. Based on the results of this study, $F_0$ and speech rates can be used to analyze the sensation types for individualized education as well as consultation. In addition, this study has great significance in that it lays a foundation for the study on the correlation between a preferred sensation type and speech sounds.

Establishment of standards for evaluation of health related fitness according to the working styles of male manufacturing workers (남성 제조업 근로자의 근무형태에 따른 건강 체력 평가기준 설정)

  • Ka, Sung-Soon;Lee, Gyu-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.190-199
    • /
    • 2017
  • The purpose of this study is to propose the standard of health-related fitness evaluation according to the working styles of male manufacturing workers. The subjects were 15,329 male manufacturing workers aged from 40 to 59 years old who had taken a health-related fitness test by K Institution. Health-related fitness components are cardiorespiratory endurance, muscular strength, muscular endurance, flexibility and body composition. We measured Vo2max, grip strength, sit-up, trunk flexion forward, and body fat percentage to ascertain each component. Data were analyzed with Two-way ANOVA, T-test, One-way ANOVA(Scheffe) and Percentile using SPSS version 18.0 program. The analysis results are as follows. First, the health-related fitness of manufacturing workers varied significantly according to their working styles(maximum oxygen uptake : F=88.67(p<.001), grip strength : F=20.09(p<.001), sit-up : F=42.06(p<.001), trunk flexion forward : F=69.44(p<.001), body fat percentage : F=136.75(p<.001)).Therefore, the evaluation standard was set based on the percentile of health fitness items. Second, the average Vo2max, grip strength, and trunk flexion forward of blue-collar workers were higher than those of white-collar workers at all ages. On the other hand, the average sit-up and body fat percentage of white-collar workers were higher than those of blue-collar workers at all ages. Third, these evaluation criteria differed greatly when compared with the results of the National Physical Fitness Survey. Therefore, we have confirmed that the evaluation criteria should be applied differently according to the working style of a worker when evaluating his health-related fitness.

Shear Load Transfer Characteristics of Friction Piles in Deep Soft Clay (대심도 연약지반상 마찰말뚝의 주면하중전이 거동 분석)

  • Moon, Joon-Shik;Paek, Jin-Yeol;Jeong, Sang-Seom;Ko, Jun-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.10
    • /
    • pp.55-67
    • /
    • 2011
  • The shear load distribution and deformation of offshore friction piles are investigated using experimental tests and a numerical analysis. Special attention is given to the soil-pile interaction of axially loaded pile. A framework for determining the f-w curve is proposed based on both theoretical analysis and experimental load test data base. A numerical analysis that takes into account the proposed f-w curves was performed for major parameters on pile-soil interaction such as the pile diameter, the pile length, and the soil condition. Based on the analysis, it is shown that the proposed f-w method is capable of predicting the behavior of a friction pile in deep soft clay. Through comparisons with case histories and finite element results, it is found that the proposed f-w curves are more appropriate and realistic m representing the pile-soil interaction of axially loaded piles in deep soft clay than that of existing f-w method.

F-Wave Analysis in Patients with Clinically Diagnosed Carpal Tunnel Syndrome (임상적으로 진단된 수근관증후군 환자에서 F파 분석)

  • Kim, Seong-Hee;Yoo, Bong-Goo;Kim, Kwangsoo;Yoo, Kyung-Moo
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.2
    • /
    • pp.108-113
    • /
    • 2002
  • Background and Objective : Carpal tunnel syndrome (CTS) is the most common mononeuropathy encountered in clinical practice. No single procedure or group of procedures has demonstrated adequate sensitivity. F-wave study in CTS is very rarely reported. To determine the diagnostic usefulness of new parameters of F-wave and comparative study of F-wave parameters of median and ulnar nerves in patients with CTS. Methods : F-wave responses of median and ulnar nerves were analyzed from 27 patients with clinically diagnosed CTS and 22 age and gender-matched normal control. Conventional F-wave parameters were studied. Also, the usefulness of new parameters such as mean and maximal ulnar-median F-wave latency differences, ulnar-median F-wave persistence and chronodispersion differences, median/ulnar F-wave amplitude ratio, and F-wave conduction velocity (FCV) using mean and maximal latency were assessed. Results : Compared with controls, median F-wave minimal, maximal and mean latencies, mean F-wave amplitude/M-wave amplitude, minimal, mean and maximal ulnar-median F-wave latency differences, and FCVs using minimal, maximal and mean latency were significant (P<0.05~0.001). Median F-wave minimal, maximal and mean latencies, mean ulnar-median F-wave latency difference, and FCVs using minimal, maximal and mean latency showed high sensitivity and specificity. Mean ulnar-median F-wave latency difference and FCVs using maximal and mean latency were new parameters. Conclusion : New F-wave parameter including mean ulnar- median F-wave latency difference and FCVs using maximal and mean latency may be a useful to assess the CTS. Also, median F-wave minimal, maximal and mean latencies, and FCV using minimal latency may be included in routine diagnostic tests in CTS.

  • PDF

Effect of MgF2 Surface Modification for LiNi0.8Co0.15Al0.05O2 Cathode Material on Improving Electrochemical Characteristics (LiNi0.8Co0.15Al0.05O2 양극활물질의 전기화학적 특성 향상을 위한 MgF2 표면처리 효과)

  • Jin, Su-Jin;Seo, Jin-Seong;Na, Byung-Ki
    • Korean Chemical Engineering Research
    • /
    • v.58 no.1
    • /
    • pp.52-58
    • /
    • 2020
  • Electrochemical characterization and thermal stability were investigated for MgF2 coated LiNi0.8Co0.15Al0.05O2 cathode. The ratio of MgF2 was controlled by 0.5, 1, 3 wt%. Cyclic voltammetry, charge-discharge profiles, rate capability, cycle life were measured for electrochemical properties. DSC analysis was measured for thermal stability. The first discharge capacities of MgF2 coated LiNi0.8Co0.15Al0.05O2 were decreased at 0.1C-rate compared to pristine LiNi0.8Co0.15Al0.05O2. But the rate capability and cycle life of MgF2 coated LiNi0.8Co0.15Al0.05O2 were improved at 2C-rate. In DSC analysis result, the exothermic temperature of MgF2 coated LiNi0.8Co0.15Al0.05O2 was increased and peak height was decreased.

An analysis of emotional English utterances using the prosodic distance between emotional and neutral utterances (영어 감정발화와 중립발화 간의 운율거리를 이용한 감정발화 분석)

  • Yi, So-Pae
    • Phonetics and Speech Sciences
    • /
    • v.12 no.3
    • /
    • pp.25-32
    • /
    • 2020
  • An analysis of emotional English utterances with 7 emotions (calm, happy, sad, angry, fearful, disgust, surprised) was conducted using the measurement of prosodic distance between 672 emotional and 48 neutral utterances. Applying the technique proposed in the automatic evaluation model of English pronunciation to the present study on emotional utterances, Euclidean distance measurement of 3 prosodic elements such as F0, intensity and duration extracted from emotional and neutral utterances was utilized. This paper, furthermore, extended the analytical methods to include Euclidean distance normalization, z-score and z-score normalization resulting in 4 groups of measurement schemes (sqrF0, sqrINT, sqrDUR; norsqrF0, norsqrINT, norsqrDUR; sqrzF0, sqrzINT, sqrzDUR; norsqrzF0, norsqrzINT, norsqrzDUR). All of the results from perceptual analysis and acoustical analysis of emotional utteances consistently indicated the greater effectiveness of norsqrF0, norsqrINT and norsqrDUR, among 4 groups of measurement schemes, which normalized the Euclidean measurement. The greatest acoustical change of prosodic information influenced by emotion was shown in the values of F0 followed by duration and intensity in descending order according to the effect size based on the estimation of distance between emotional utterances and neutral counterparts. Tukey Post Hoc test revealed 4 homogeneous subsets (calm

A Case Study on the R&D Programs of Fighter & Attacker Aircraft (군용항공기 연구개발 사업 사례분석)

  • Lee, Sung Eun;Kwon, Yong Soo
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.5 no.1
    • /
    • pp.7-20
    • /
    • 2009
  • This paper describes a case study on the R&D programs of fighter and attacker aircraft such as F-22A, F/A-18E/F, and T/A-50. F-22A and F/A-18E/F were developed in same age. The performance of each program was, however extremely different. F-22A program results in a lot of cost overrun and schedule delay. On the other hand F/A-18E/F program met the cost, schedule, and performance goals. In the T/A-50 program with a super-sonic advanced trainer, T-50 was also developed successfully on planned cost and time by Korea Air-force and KAI. This paper derives key elements for the success of the military aircraft R&D program through lessons learned from th e case study. Each program is analyzed in terms of its background, planning and management.

  • PDF

Photoluminescence of the Single Crystal MnF2(1.5% EuF3) (단결정 MnF2(1.5% EuF3)의 Photoluminescence)

  • Kwon, Soon-Hyuk;Nahm, Kyun;Kim, Chul-Koo
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • The 1R(Infra-Red) spectrum and PL(Photoluminescence) of the antiferromagnetic pure $MnF_2$ and the single crystal $MnF_2(1.5%\;EuF_3)$ with the rutile structures were measured. The detailed analysis of the measured PL data showed the differences of the optical property between the single crystal $MnF_2(1.5%\;EuF_3)$ and the pure $MnF_2$. It was found that the additional PL peak by the doping of the $EuF_3$ in $MnF_2$ is originated from the f-d transition of $Eu^{3+}$ from the temperature dependent intensity measurement.