• Title/Summary/Keyword: F-B function system

Search Result 67, Processing Time 0.02 seconds

Stacked Pad Area Away Package Modules for a Radio Frequency Transceiver Circuit (RF 송수신 회로의 적층형 PAA 패키지 모듈)

  • Jee, Yong;Nam, Sang-Woo;Hong, Seok-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.10
    • /
    • pp.687-698
    • /
    • 2001
  • This paper presents a three dimensional stacked pad area away (PAA) package configuration as an implementation method of radio frequency (RF) circuits. 224MHz RF circuits of intelligence traffic system(ITS) were constructed with the stacked PAA RF pakage configuration. In the process of manufacturing the stacked PAA RF pakage, RF circuits were partitioned to subareas following their function and operating frequency. Each area of circuits separated to each subunits. The operating characteristics of RF PAA package module and the electrical properties of each subunits were examined. The measurement of electrical parameters for solder balls which were interconnects for stacked PAA RF packages showed that the parasitic capacitance and inductance were 30fF and 120pH, respectively, which might be negligible in PAA RF packaging system. HP 4396B network/spectrum analyzer revealed that the amplification gain of a receiver and transmitter at 224 MHz was 22dB and 27dB, respectively. The gain was 3dB lower than designed values. The difference was probably generated from fabrication process of the circuits by employing commercial standard

  • PDF

Rapid Depressurization Capability of Monobloc Sebim Valves for KNGR Total Loss of Feedwater Event

  • Kwon, Young-Min;Lim, Hong-Sik;Song, Jin-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.389-394
    • /
    • 1996
  • The conceptual design of Korea Next Generation Reactor (KNGR), which is 3914 MWt PWR, includes the safety depressurization system (SDS) to comply with U.S. NRC's severe accident policy. In this analysis, it is assumed that three Monobloc Sebim valves are adopted for the SDS bleed valves of KNGR. The characteristic of Monobloc Sebim are modeled in the CE-FLASH-4AS/REM code for this analysis. The various feed and bleed (F&B) procedures with Sebim valves are investigated for total loss of feedwater (TLOFW) event. It is found that if operators open two out of three Sebim valves in conjunction with four HPSI pumps before hot leg temperature reaches saturation condition, the decay heat removal and core inventory make-up function can be successfully accomplished. Therefore, this F&B procedure can be used for mitigating the TLOFW event of the KNGR. This result also demonstrates the feasibility of adopting the Monobloc Sebim valves for the SDS of KNGR.

  • PDF

Comparision of cardiovascular and analgesic effects of epidural administration of medetomidine, medetomidine-buprenorphine and medetomidine-fentanyl in dogs anesthetized with isoflurane (Isofourane으로 마취된 개에 medetomidine, medetomidine-buprenorphine, medetomidine-fentanyl의 경막외 투여 시 심혈관계 반응과 진통효과의 비교)

  • Chang, Hwa-Seok;Kim, Hye-Jin;Choi, Chi-Bong;Lee, Jung-Sun;Kim, Hwi-Yool
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.1
    • /
    • pp.103-115
    • /
    • 2007
  • The aim of this study was to compare the reaction of the cardiovascular system, and the anesthetic effect among 3 experimental groups, epidural administration of medetomidine as a single agent, the combination of buprenorphine and medetomidine, and the combination of fentanyl and medetomidine. Twenty one dogs were anesthetized with isoflurane and allowed to breathe spontaneously. Epidural, arterial, and venous catheters were inserted. The tip of epidural catheter was positioned at the level of the space between the sixth and seventh lumbar vertebra. After a stable plane of anesthesia was achieved, these dogs were each administered one of the following treatments epidurally : medetomidine $10{\mu}g/kg$ (Group M), a combination of medetomidine $5{\mu}g/kg$ and buprenorphine $10{\mu}g/kg$ (Group M/B), and a combination of medetomidine $5{\mu}g/kg$ and fentanyl $10{\mu}g/kg$ (Group M/F). Heart rate (HR), Respiratory rate (RR), End-tidal carbon dioxide (EtCO2), and arterial blood pressure were measured before drug administration (base line) and 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, and 60 min postinjection. Blood gas analysis was performed before injection and 5, 15, 25, 35, 45, 60 min postinjection. Isoflurane was discontinued 80 min postinjection and pain/motor function were evaluated up to 260 min postinjection every 15 min. At the early stage of drug introduction (until 5 min), the HR was decreased significantly in all 3 groups compared with base line. In Group M, HR was significantly decreased compared with the other 2 groups. With time (starting 20 min after drug introduction), the HR was decreased significantly in Group M/B in respect to base line. However, no significant difference was seen number-wise in all 3 groups. During 60 min after drug introduction, the systolic, diastolic and mean arterial pressures were highest in Group M and lowest in Group M/F. Among 3 groups, drug action and motor loss duration were longest in Group M/F. Analgesic effect observed in the M/F group was the most prominent and long-lasting, compared to those seen in the other 2 groups. Given the fact that the recovery of motor function takes place in a short period of time after analgesic effects disappeared, additional use of M/F depending on the patient's condition would be a good way to achieve effective pain management. However, proper care should be taken to ensure the function of cardiovascular system in the patient because the administration of M/F under isoflurane anesthesia results in a significant decline in arterial blood pressure ($65{\pm}10mmHg$).

A Study on the Function Generating Capability of the Fuzzy Controllers (퍼지 제어기의 함수 구현능력에 대한 연구)

  • Lee, Ji-Hong;Chung, Byoung-Hyun;Chae, Seog;Oh, Young-Seok
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.7
    • /
    • pp.87-97
    • /
    • 1992
  • Fuzzy controllers have been successfully applied to many cases to which conventional control algorithms are difficult to be applied. Even though the representations and the processings of data and information in the fuzzy controller are quite different from those in other control algorithms, the information processing operation that it caries out is basically a function ∫: $A{\subset}R^n{\to}R^m$, from a bounded subset A of an n-dimensional Euclidean space to a bounded subset f[A] of an m-dimensional Euclidean space, where n and m are the number of measured states and the number of control inputs of the controlled system, respectively. Under the assumptions of Mamdani's direct reasoning method and C.O.G.(center of gravity) defuzzification method, the fuzzy controllers are proven to perform the mapping of any given functions f with appropriately defined fuzzy sets. The mapping capabilities of fuzzy controllers are analyzed in detail for two cases, ∫: $R^{1}{\to}R^{1}$ and g: $R^{2}{\to}R^{1}$. Also, it will be shown that the results can be extended to multiple dimensional cases.

  • PDF

A Study on Measuring Method in Technical Progress (기술진보 측정방법에 관한 일고안)

  • 박일근
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.3 no.3
    • /
    • pp.59-66
    • /
    • 1980
  • The purpose of this paper to study on measuring method in technical progress. Technology is combination method of raw material and capital, land, labour. The first step to technical Progress is COBB-DOUGLAS production function, so technical progresses are important role in economic growth and development. General production function from Y=f(K, L, T) and COBB-DOUGLAS production function Y=${AK^I}{L^b}$ is first condition. Technical progress is saving of production factor In capital saving, labour saving, neutral saving. Marred Hicks Robinson has Insist on technical progress by each view of production factor, but, what is most excellent measuring method of technical progress\ulcorner I : productivity index method. II : Gross Production function method. Productivity method used in every products level in weight values, gross method function method used in production factor attributed to products. Above two measuring method has delicate problem in each input factor, substitution relation and production factor simultaneously linked each others This basic problem based on technical progress is not solubable in this time.

  • PDF

A Similitude Study of Soil-Wheel System for Identifying the Dimension of Pertinent Soil Parameter(I) -Pull Prediction Analysis- (구동륜(驅動輪)의 성능예측(性能豫測)에 적합한 토양변수(土壤變數)의 차원해석(次元解析)을 위한 차륜(車輪)-토양(土壤) 시스템의 상사성(相似性) 연구(硏究)(I) -견인력(牽引力) 예측(豫測) 분석(分析)-)

  • Lee, K.S.;Chung, C.J.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.2
    • /
    • pp.67-79
    • /
    • 1989
  • This study was conducted to investigate the applicability of true model theory for pull prediction in a powered lugged wheel-soil system and to examine the possibility of using principles of similitude in investigating the dimensions of soil parameters pertinent to a powered lugged wheel-soil system concerning the pull prediction. The following conclusions were derived from the study; 1) The pull of prototype wheels proved to be predicted by those of the model wheels for the range of the dynamic weight tested. The pull curves of models and prototype were respectively very similar in the shape. From this basic knowledge, it was enabled to apply the similitude theory to the performance prediction of the true model. 2) A conditional equation which can be used for the prediction of pull of prototype by model test was derived as follows. $n_f=n_1^{-b}$ where $n_f$ : force scale = $w/w_m$ $n_1$ : length scale = ${\ell}/{\ell}_m$ b : exponent on the length dimension of the soil property ${\alpha}$ The range of the numerical value of b, which was determined by the least square method, was found to be -2.0~-2.6. 3) Considering a relatively wide variation of b values in the pull prediction, b is considered to be a function of many variales. Thus it was concluded that there are several soil properties which are pertinent to the powered lugged-wheel-soil system concerning the pull prediction, and these soil properties may have the different effects on the pull of model and protytype wheels, to give the different dimension on the soil parameters.

  • PDF

Characteristics of Superconductive Pb shield for a Whole Head MEG System (헬멧형 뇌자도 장치로의 활용을 위한 Pb 초전도 차폐의 특성)

  • Yu, K.K.;Kim, K.;Lee, Y.H.;Kwon, H.
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.30-35
    • /
    • 2009
  • We have investigated the characteristics of a superconductive Pb shield for hemispherical shape and plate to improving signal-to-noise ratio(SNR) of biomagnetism. We measured the shielding factor for the position of helmet shape Pb and for changing the distance from Pb surface. To make a uniform magnetic field, a $1.5m{\times}1.5m$ set of the helmholtz coils activated at several frequencies. The shielding factor of hemispherical shape Pb was from 20 to 57 dB and of Pb plate was about $6{\sim}26dB$ as a function of distance from the lead surface. The shielding factor was rapidly reduced as increasing the distance from Pb surface. The white noise of superconductive quantum interference device(SQUID) with a superconductive shield was about $12fT/Hz^{1/2}$ at 1 Hz, $7fT/Hz^{1/2}$ at 100 Hz. The white noise was more increased about two times than conventional SQUID system without Pb shielding. An auditory signal was measured by first order gradiometer and magnetometer with Pb superconductive shield and compared the SNR. The SQUID system with Pb shield had better performance at low frequency noise level.

  • PDF

Effect on 4H-SiC Schottky Rectifiers of Ar Discharges Generated in A Planar Inductively Coupled Plasma Source

  • Jung, P.G.;Lim, W.T.;Cho, G.S.;Jeon, M.H.;Lee, J.W.;Nigam, S.;Ren, F.;Chung, G.Y.;Macmillan, M.F.;Pearton, S.J.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.1
    • /
    • pp.21-26
    • /
    • 2003
  • 4H-SiC Schottky rectifiers were exposed to pure Ar discharges in a planar coil Inductively Coupled Plasma system, as a function of source power, of chuck power and process pressure. The reverse breakdown voltage ($V_B$) decreased as a result of plasma exposure due to the creation of surface defects associated with the ion bombardment. The magnitude of the decrease was a function of both ion flux and ion energy. The forward turn-on voltage ($V_F$), on-state resistance ($R_{ON}$) and diode ideality factor (n) all increased after plasma exposure. The changes in all of the rectifier parameters were minimized at low power, high pressure plasma conditions.

A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes (기능성 전문테니스화의 족저압력분포 분석)

  • Lee, J.S.;Kim, Y.J.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.

A NEW ALGORITHM OF THE STATE-MINIMIZATION FOR THE NONDETERMINISTIC FINITE AUTOMATA

  • Melnikov, B.F.
    • Journal of applied mathematics & informatics
    • /
    • v.6 no.2
    • /
    • pp.379-392
    • /
    • 1999
  • The problem of the state-minimization for the nonde-terministic finite Rabin-Scott's automata is considered. A new algo-rithm for this problem is obtained. The obtained algorithm has the exponential effectiveness like the earlier-known algorithms for this problem. But each of previous algo-rithms amounts to the search of minimum generative system for local reaction of equal automaton of canonical form and unlike them we use in this paper two special function marking states of the given automaton.