Rapid Depressurization Capability of Monobloc Sebim Valves for KNGR Total Loss of Feedwater Event

  • Kwon, Young-Min (Korea Atomic Energy Research Institute(KAERI) Systems Safety Analysis Department) ;
  • Lim, Hong-Sik (Korea Atomic Energy Research Institute(KAERI) Systems Safety Analysis Department) ;
  • Song, Jin-Ho (Korea Atomic Energy Research Institute(KAERI) Systems Safety Analysis Department)
  • Published : 1996.11.01

Abstract

The conceptual design of Korea Next Generation Reactor (KNGR), which is 3914 MWt PWR, includes the safety depressurization system (SDS) to comply with U.S. NRC's severe accident policy. In this analysis, it is assumed that three Monobloc Sebim valves are adopted for the SDS bleed valves of KNGR. The characteristic of Monobloc Sebim are modeled in the CE-FLASH-4AS/REM code for this analysis. The various feed and bleed (F&B) procedures with Sebim valves are investigated for total loss of feedwater (TLOFW) event. It is found that if operators open two out of three Sebim valves in conjunction with four HPSI pumps before hot leg temperature reaches saturation condition, the decay heat removal and core inventory make-up function can be successfully accomplished. Therefore, this F&B procedure can be used for mitigating the TLOFW event of the KNGR. This result also demonstrates the feasibility of adopting the Monobloc Sebim valves for the SDS of KNGR.

Keywords