• Title/Summary/Keyword: F&M Test

Search Result 941, Processing Time 0.028 seconds

A Study on the Test of Mean Residual Life with Random Censored Sample (임의 절단된 자료의 평균잔여수명 검정에 관한 연구)

  • 김재주;이경원;나명환
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.3
    • /
    • pp.11-21
    • /
    • 1997
  • The mean residual life(MRL) function gives the expected remaining life of a item at age t. In particular F is said to be an increasing intially then decreasing MRL(IDMRL) distribution if there exists a turing point $t^*\ge0$ such that m(s)$\le$ m(t) for 0$$\le s$\le$ t $t^*$, m(s)$\ge$ m(t) for $t^*\le$ s$\le$ t. If the preceding inequality is reversed, F is said to be a decreasing initially then increasing MRL(DIMRL) distribution. Hawkins, et al.(1992) proposed test of H0 : F is exponential versus$H_1$: F is IDMRL, and $H_0$ versus $H_1$' : F is DIMRL when turning point is unknown. Their test is based on a complete random sample $X_1$, …, $X_n$ from F. In this paper, we generalized Hawkins-Kochar-Loader test to random censored data.

  • PDF

Reliability and Validity of the Korean Version of the Short Michigan Alcoholism Screening Test for Fathers and Mothers (부모의 음주문제를 선별하는 도구의 신뢰도 및 타당도 분석 -한국어판 Short Michigan Alcoholism Screening Test for Fathers and Mothers의 평가-)

  • Kim, Yong-Seok
    • Korean Journal of Social Welfare
    • /
    • v.56 no.3
    • /
    • pp.37-59
    • /
    • 2004
  • Short Michigan Alcoholism Screening Test for Fathers(F-SMAST) and Mothers(M-SMAST) is to measure the presence of an alcohol use disorder in one's father and/or mother. The purpose of this study is to evaluate the Korean version of the F-SMAST and M-SMAST. A total of 241 college students, who resided in Seoul and two other cities, participated in this study. The internal consistency of the Korean version of the F-SMAST and M-SMAST was assessed using alpha coefficient. The alpha coefficient of both the F-SMAST and the M-SMAST was 0.82. Standard Errors of Measurement(SEM) were also computed. SEMs of the F-SMAST and the M-SMAST were quite low. With a cut-off score of 3, the F-SMAST correctly identified 91 percent of respondents who were presumed to be children of alcoholics and correctly identified 81 percent of respondents who were presumed not to be children of alcoholics. Sensitivity and specificity of the M-SMAST with a cut-off score of 1 are 0.33 and 0.81, respectively. Several variables were examined in relation to the F-SMAST and the M-SMAST to examine convergent and discriminant validity. It was found that the F-SMAST and the M-SMAST were significantly correlated with most of convergent variables(average amount of drinking per day, AUDIT, distress) and had not statistically significant relationships with discriminant variables(demographic variables). This study suggests that the Korean version of the F-SMAST and the M-SMAST be repeatedly assessed across different sample in order to confirm the findings of this study.

  • PDF

A Study of Quality Control Environment of Mammography (유방촬영의 화질관리 환경에 대한 고찰)

  • Hwang, In-Sun;Kim, Young-Keun;Joo, Hyung-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • The purpose of this study was to survey and test quality control of mammography system. The conclusion of this study is as follows ; First, The rate of pass for phantom image test shows that Film-Screen mammography system(F/S) and computed mammography system(CR) is 80%, Indirect digital mammography system(DR) is 100%. Second, The test of exposure dose shows that F/S is 921 mR. CR is 1,140 mR, DR is 474 mR. The grade of this testament is CR > F/S > DR. Third, The test of average glandular dose shows that F/S is 1,336 mGy, CR is 1,635 mGy, DR is 1,26 mGy. The grade of this testament is CR > F/S > DR. Fourth, The testament of resolution shows as follows F/S is 11~13 Lp/mm, CR is 4~5 Lp/mm, and DR is 5~7 Lp/mm(F/S > DR > CR) Fifth, The survey of projection, cassette, development and reading shows that user are indifference.

  • PDF

Influence of Notch Change on Corrosion Fatigue Fracture in F.E.M. Dual phase Steel of SS41 Steel (SS41강의 F.E.M.복합조직강에서 노치변화가 부식피로파괴에 미치는 영향)

  • 도영민;이규천
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.44-50
    • /
    • 2001
  • The rotated bending fatigue test was conducted in air md in 3.5% NaCl salt solution to investigate the fatigue fracture behaviour of raw material and F.E.M dual phase steel made from raw material(SS41) by a suitable heat treatment. This study has compared the initial microcrack creation of material by tensile test with that by fatigue test. And the rotated bending test of cantilever type under the condition of 3.5% NaCl salt solution and air has investigated the corrosion fatigue fracture behaviour with the variation of stress concentration factor determined by each of notch shapes. The initial microcrack have been developed in fragile grainboundary with general corrosion occurring in raw material : in the pits built up by corrosion in F.E.M. dual phase steel because pits bring out stress concentration. It is small that the degree of decrease in corrosion fatigue life for F.E.M. dual phase steel compared with raw material because the notch sensitivity of F.E.M. dual phase steel is lower than raw material in reason of characteristics with two-phase construction.

  • PDF

Development of a 6-axis robot′s finger force/moment sensor for stable grasping of an unknown object

  • Kim, Gab-Soon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.3
    • /
    • pp.54-61
    • /
    • 2004
  • This paper describes the development of a 6-axis robot's finger force/moment sensor, which measures forces $F_x$(x-direction force), $F_y$and $F_z$, and moments $M_x$ (x-direction moment), $M_y$ and $M_z$ simultaneously, for stable grasping of an unknown object. In order to safely grasp an unknown object using the robot's gripper, the force in the gripping direction and the force in the gravity direction should be measured, and the force control should be performed using the measured forces. Also, the moments $M_x$, $M_y$ and $M_z$ to accurately perceive the position of the object in the grippers should be detected. Thus, the robot's gripper should be composed of 6-axis robot's finger force/moment sensor that can measure forces $F_x$, $F_y$ and $F_z$, and moments $M_x$ $M_y$ and $M_z$ simultaneously. In this paper, the 6-axis robot's finger force/moment sensor for measuring forces $F_x$, $F_y$ and $F_z$, and moments $M_x$ $M_y$ and $M_z$ simultaneously was newly modeled using several parallel-plate beams, designed, and fabricated. The characteristic test of the fabricated sensor was performed, and the result shows that interference errors of the developed sensor are less than 3%. Also, Robot's gripper with the 6-axis robot's finger force/moment sensor for the characteristic test of force control was manufactured, and the characteristic test for grasping an unknown object using the sensors was performed using it. The fabricated gripper could grasp an unknown object stably. Thus, the developed 6-axis robot's finger force/moment sensor can be used for robot's gripper.

Friction and Wear Behaviors of WC-Co/WC-Co Pairs in Air

  • Hosokawa, H.;Nakajima, T.;Shimojima, K.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.629-630
    • /
    • 2006
  • To investigate sliding friction and wear behaviors of WC-Co/WC-Co pairs containing different WC grain sizes, the ball-on-disc test in air were carried out, where WC grain sizes a $0.5\;{\mu}m$ (F.G.) and $1.5\;{\mu}m$ (C.G.). The wear volume of F.G. pin for F.G. pin/C.G. disc is larger than that of F.G. pin for F.G. pin/F.G. disc due to higher friction coefficient, and the surfaces after wear test are richer in oxygen compared to those before test. Furthermore, the wear debris, which is composed of nona-scale grain, after the wear test are remarkably richer in oxygen than to those before test.

  • PDF

SCHUR POWER CONVEXITY OF GINI MEANS

  • Yang, Zhen-Hang
    • Bulletin of the Korean Mathematical Society
    • /
    • v.50 no.2
    • /
    • pp.485-498
    • /
    • 2013
  • In this paper, the Schur convexity is generalized to Schur $f$-convexity, which contains the Schur geometrical convexity, harmonic convexity and so on. When $f$ : ${\mathbb{R}}_+{\rightarrow}{\mathbb{R}}$ is defined as $f(x)=(x^m-1)/m$ if $m{\neq}0$ and $f(x)$ = ln $x$ if $m=0$, the necessary and sufficient conditions for $f$-convexity (is called Schur $m$-power convexity) of Gini means are given, which generalize and unify certain known results.

Biodegradation test of the alternatives of perfluorooctanesulfonate (PFOS) and PFOS salts (PFOS salts 및 PFOS 대체물질에 대한 미생물분해시험)

  • Choi, Bong-In;Na, Suk-Hyun;Son, Jun-hyo;Shin, Dong-Soo;Ryu, Byung-taek;Chung, Seon-yong
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.2
    • /
    • pp.112-117
    • /
    • 2016
  • Objectives: In this study, we investigated the biodegradation rates of 8 perfluorooctanesulfonate (PFOS) alternatives synthesized at the at Changwon National University in comparison to those of PFOS potassium salt and PFOS sodium salt. Methods: A biodegradability test was performed for 28 days with microorganisms cultured in the good laboratory practice laboratory at the Korea Environment Corporation following the OECD Guidelines for the testing of chemicals, Test No. 301 C Results: While $C_5H_8F_3SO_3K$, $C_8F_{17}SO_3K$ and $C_8F_{17}SO_3Na$ were not degraded after 28 days, the 3 alternatives were biodegraded at the rates of 31.4% for $C_8H_8F_9SO_3K$, 25.6% for $C_{10}H_8F_{13}SO_3K$, 23.6% for $C_{25}F_{17}H_{32}S_3O_{13}Na_3$, 20.9% for $C_{15}F_9H_{21}S_2O_8Na_2$, 15.5% for $C_{23}F_{18}H_{28}S_2O_8Na_2$, 8.5% for $C_{17}F_9H_{25}S_2O_8Na_2$ and 4.8% for $C_6H_8F_5SO_3K$. When the concentration was the same(500 mg/L), $C_{23}F_{18}H_{28}S_2O_8Na_2$ had the lowest tension with 20.94 mN/m, which was followed by $C_{15}F_9H_{21}S_2O_8Na_2$ (23.36 mN/m), $C_{17}F_9H_{25}S_2O_8Na_2$ (27.31 mN/m), $C_{25}F_{17}H_{32}S_3O_{13}Na_3$ (28.17 mN/m), $C_{10}H_8F_{13}SO_3K$ (29.77 mN/m) and $C_8H_8F_9SO_3K$ (33.89 mN/m). Having higher surface tension of 57.64 mN/m and 67.57 mN/m, respectively, than those of the two types of PFOS salts, $C_6H_8F_5SO_3K$ and $C_5H_8F_3SO_3K$ were found valueless as substitute for PFOS. Conclusion: The biodegradation test suggest that 6 compounds could be used as substitutes for PFOS. $C_{23}F_{18}H_{28}S_2O_8Na_2$ and $C_{15}F_9H_{21}S_2O_8Na_2$ were found to be the best substitutes based on biodegradation rate and surface tension, followed by $C_{25}F_{17}H_{32}S_3O_{13}Na_3$, $C_8H_8F_9SO_3K$ and $C_{10}H_8F_{13}SO_3K$. $C_{17}F_9H_{25}S_2O_8Na_2$ was found to have relatively low value as an alternative but it still had a potential to substitute the conventional PFOS.

Anaerobic Digestion Treatment for the Mixture of Chinese Cabbage Waste Juice and Swine Manure

  • Kafle, Gopi Krishna;Kim, Sang-Hun;Shin, Beom-Soo
    • Journal of Biosystems Engineering
    • /
    • v.37 no.1
    • /
    • pp.58-64
    • /
    • 2012
  • Purpose: The objective of this study was to investigate the feasibility of anaerobic digestion of Chinese cabbage waste juice (CCWJ) and swine manure(SM). Methods: The anaerobic digestion test was conducted under batch and continuous conditions at mesophilic temperature ($36-38^{\circ}C$). The batch test was divided into Experiment I and II. In the Experiment I, biogas potential and production rate of CCWJ was evaluated. In Experiment II the effect of F/M ratio (2.0, 3.2, 4.9) at mixture ratio of 25:75(CCWJ: SM, % vol. basis) on biogas yield was studied. Results: CCWJ produced biogas and methane yield of 929 and 700 mL/g VS added respectively. The biogas yield from the mixture of CCWJ and SM was almost same at F/M ratio of 2.0 and 3.2 but dropped by 14% when F/M ratio increased from 3.2 to 4.9. In continuous test the mixture of CCWJ and SM (25:75, % vol. basis) produced biogas yield of 352 mL/g VS added which is around 11% higher compared to biogas yield from SM alone. Addition to biogas yield digester performance was also improved with co-digestion of CCWJ with SM. Conclusions: The results showed that the anaerobic digestion of CCWJ with SM could be promising for improving both the biogas yield and digester performance at mesophilic temperature.

The Reliability and Validity of Figure-of-8 Walk Test in Patients with Stroke (뇌졸중 환자에서 Figure-of-8 walk test의 신뢰도와 타당도)

  • Kim, Yang-Ho;Lim, Jae-Heon
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • Purpose : The purpose of this study was to establish intra-rater, inter-rater, test-retest reliability, and concurrent validity of figure-of-8 walk test in people with stroke. Methods : The subjects of this study were 17 patients who were diagnosed with a stroke. Subjects were tested twice by the same raters, with 1 day between tests. Subjects were assessed by two physical therapists. Test-retest reliability was calculated using intraclass correlation coefficients (ICC). The concurrent validity was demonstrated by spearman correlation of F8WT with 10m walking test (10MWT), timed up and go test (TUG), Berg balance scale (BBS), dynamic gait index (DGI) and four square step test (FSST). Results : Intra-rater, inter-rater, test- retest of F8WT time, showed high reliability. Intra-rater, inter-rater, test-retest of F8WT steps demonstrated high reliability. Intra-rater, inter-rater, test-retest of F8WT total smoothness score showed below moderate reliability. There was a significant positive correlation of F8WT time with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT time with DGI, BBS. There was a significant positive correlation of F8WT steps with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT steps with DGI. There was a significant positive correlation of F8WT test total smoothness score with BBS. Conclusion : The time, and number of steps in F8WT show high inter, intra-rater, test-retest reliability. The F8WT smoothness shows below moderate reliability. The F8WT shows high concurrent validity with other comparable balance, and walking tests. The F8WT is a valid and reliable measure for assessing walking function in patients with a stroke.