• 제목/요약/키워드: Extinguishing Test

검색결과 104건 처리시간 0.018초

질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구 (A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas)

  • 임우섭;정종진;남동군;사공성호;김종원;최근주
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.

강화액 소화성능평가에 관한 연구 (A Study on the Fire Extinguishing Ability Rating of Load Streams)

  • 권성필;김형권;윤헌주;사공성호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.159-162
    • /
    • 2008
  • A standard fire extinguishing tester, with which we could conduct the fire extinguishing ability rating of a water-based fire extinguishing agent such as water and loaded stream, has been developed in this work. It could help us enhancing the efficiency and reliability of the fire extinguishing test of loaded streams, and at last increasing the productivity of fire protection related firms. Furthermore, our country could take the lead in making a new standard for the fire extinguishing test of loaded streams. As a result, it is expected that loaded streams could be improved by using it. In addition the standard fire extinguishing tester could be made moderately in our industry, and supplied at home and worldwide.

  • PDF

가스계 혼합소화약제의 불꽃소화농도 (Flame Extinguishing Concentrations of Mixed Gaseous Agents)

  • 김재덕;임종성;이윤우;이윤용
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.34-40
    • /
    • 2001
  • 가스계 혼합소화약제의 소화성능을 검토하기 위하여 Cup-burner test장치를 설치하고 이성분계 및 삼성분계 혼합물의 불꽃소화농도를 측정하였다. 시험대상 이성분계 혼합물은 이산화탄소/HFC-23, 이산화탄소/HCFC-22, 이산화탄소/HFC-227ea, 이산화탄소/HFC-125, 이산화탄소/FIC-13I1, Hexafluoropropylene/HFC-23이고 삼성분계 흔합물은 이산화탄소/HFC-237HFC-l34a, 이산화탄소/HFC-23/HFC-227ea, 이산화탄소/HFC-23/HFC-125이다. Cup-burner test장치에서 측정된 가스계 혼합물의 소화농도는 단일성분의 소화농도와 혼합물의 구성비로 이루어진 모델에 의해 잘 예측됨을 알 수 있었다. 특히 이 모델은 혼합물의 구성성분이 물리적 소화성능을 지닐 때 잘 적용되며 화학적 소화성능의 영향이 강해질수록 측정값과의 오차가 커진다.

  • PDF

전역방출방식 CO2 소화설비의 설계농도 및 유지시간 검증을 위한 직접방사실험에 관한 연구 (A Study on the Direct Discharge Test for Verifying Design Concentration and Soaking Time for CO2 Fire Extinguishing System of Total Flooding)

  • 이세명;문성웅;유상훈
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.15-23
    • /
    • 2012
  • $CO_2$ 소화설비의 소화성능 시험방법에는 직접시험방법이 가장 좋지만, 고비용과 환경문제 그리고 시험절차의 어려움으로 간접시험방법을 사용하는 경우가 많다. 그러나 석유화학플랜트나 원자력발전소와 같은 국가 중요위험시설은 화재가 발생하면 대형피해가 발생할 수 있으므로 직접방사시험을 통해 소화성능을 검증할 필요가 있다. 본 연구는 국가 중요위험시설에 설치된 전역방출방식의 $CO_2$ 소화설비 중에서 표면화재 방호구역과 심부화재 방호구역을 각각 선정하여 $CO_2$ 소화설비의 소화성능을 검증해 보았다. 소화성능은 방호구역 내에 방사된 $CO_2$의 농도가 설계농도기준(NFSC 및 NFPA)에 만족해야 그 성능을 인정받을 수 있다. 여기서, 설계농도는 $CO_2$ 소화약제가 화염을 제어할 수 있는 소화농도에 여유율 20 %를 감안한 농도를 의미한다. 시험결과 표면화재와 심부화재 방호구역 모두 $CO_2$ 설계농도를 확보하고 있음을 확인하였고 심부화재의 경우에는 20분 이상 설계농도가 유지되었다. 본 연구를 통해 국가 중요위험시설에 대한 직접방사시험 방법 및 판정방법을 소개하였고 향후 이와 같은 국가 중요위험시설에는 직접방사시험을 통해 소화설비의 신뢰성을 검증해야 할 필요성을 제기하였다.

할론대체물질의 새로운 불꽃소화농도 측정장치에 관한 연구 (A Study on the Measurement of Flame Extinguishing Concentration of Halon Alternatives by New Test Equipment)

  • 김재덕;임종성;이윤우;이윤용
    • 한국화재소방학회논문지
    • /
    • 제8권1호
    • /
    • pp.3-8
    • /
    • 1994
  • A new test system was established to measure the flame extinguishing concentration of Halon alternatives. The main characteristic of this system is to use the solid paraffin with a wick instead of liquid fuel, such as n-Heptane. Our results showed that the extinguishing concentration of compounds was lower than that of other existing data, but the trend was consistent with others. The flame extinguishing concentration of all tested compounds were not almost effected by gas flow velocity. The system produces good reliable data with a minimum error for measuring the flame extinguishing concentration. Therefore our new system can be utilized as a standard equipment to evaluate Halon alternatives.

  • PDF

$CO_2$ 소화설비 구성부품 성능시험보고 (The Report on Test Results of CO Fire Extinguishing System)

  • 김기옥;이찬주;안병호
    • 방재기술
    • /
    • 통권14호
    • /
    • pp.5-12
    • /
    • 1993
  • This report is explained about test results of carbon dioxide extinguiching system components and pack-age type system (Kits) for automatic fire extinguishing system. A carbon dioxide system may be used to protect one or more hazards or hazards by menas of directional valves. Package system shall be installed to protect hazards within the limitations. The testing program was progressed by three items, external oppearance test, performance test and Total Flooding Fire Extinguishing System test. The object of this report is present the problem which apperar from the analysis of test results.

  • PDF

가스계 소화설비의 제한사항 및 성능평가를 위한 배관 내 약제비율에 관한 연구 (A Study on Percent Agent in Pipe as a Criterion to Evaluate Limitations and Performance of Gaseous Fire Extinguishing Systems)

  • 손봉세;김희우
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.1-11
    • /
    • 2007
  • 본 연구에서는 할론 1301 및 이산화탄소를 비롯한 가스계소화설비의 성능을 시험하고 평가하기 위한 가장 중요한 핵심 요소인 배관내 약제비율, 관경비 등 소화성능에 영향을 미치는 가스계소화설비의 제한사항 및 성능확보에 필요한 요소에 대하여 연구하였다. 또한 본 연구에서는 관련 국내외 기준 분석 및 국내 가스계소화설비의 성능평가에 관한 인정기준(KFIS 002)에 따른 시스템 성능시험을 실시하고 결과를 비교 분석하였다.

노벡을 이용한 유기물의 소화농도 측정에 관한 연구 (A Study on Measuring of Fire Extinguishing Concentration for Organic Material Using Novec)

  • 임우섭;사공성호;정종진;남동군;최근주;안상수;김종원
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.456-460
    • /
    • 2008
  • This study was on basic step to develop a good clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using Novec which is inert gas. In study used to Cup Burner Test its made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test. The finding is that a new clean agent, Novec has a very efficient extinguishing ability in a state of gas.

  • PDF

소형선박 무인기관실에 적합한 소화장치 개발연구 (A Study on the Development of Fire Extinguishing System for Machinery Spaces of a Small Ship)

  • 김동석;강대선
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.130-131
    • /
    • 2005
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small ship was performed. Fire tests were conducted inside the compartments having volums 8$m^3$, 2.9$m^3$ and 4.5$m^3$ respectively. The openings and fans were established on the walls of the compartments. Diesel oil was used for the test fuel. In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF

무인기관실에 효과적인 자동소화장치개발 관한 연구 (A Study on the Development of Fire Extinguishing System for Machinery Spaces of a Small craft)

  • 이찬재;강대선;김동석;곽지현
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.127-128
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small boats was performed. Fire tests were conducted inside the compartments having volumes 2.9, 4.5, $8m^3$ respectively. The openings and fans were established on the walls of the compartments. Diesel oil was used for the test fuel, In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF