• 제목/요약/키워드: Exterior joint

검색결과 164건 처리시간 0.024초

Test of Headed Reinforcement in Pullout II: Deep Embedment

  • Choi, Dong-Uk
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.151-159
    • /
    • 2006
  • A total of 32 pullout tests were performed for the multiple headed bars relatively deeply embedded in reinforced concrete column-like members. The objective was to determine the minimum embedment depth that was necessary to safely design exterior beam-column joints using headed bars. The variables for the experiment were embedment depth of headed bar, center-to-center distance between adjacent heads, and amount of supplementary reinforcement. Regular strength concrete and grade SD420 reinforcing steel were used. The results of the test the indicated that a headed bar embedment depth of $10d_b$ was not sufficient to have relatively closely installed headed bars develop the pullout strength corresponding to the yield strength. All the experimental variables, influenced the pullout strength. The pullout strength increased with increasing embedment depth and head-to-head distance. It also increased with increasing amount of supplementary reinforcement. For a group of closely-spaced headed bars installed in a beam-column joint, it is recommended to use column ties at least 0.6% by volume, 1% or greater amount of column main bars, and an embedment depth of $13d_b$ or greater simultaneously, to guarantee the pullout strength of individual headed bars over 125% of $f_y$ and ductile load-displacement behavior.

단지형 도시근교주거의 현황 및 선호 조사 (A Study on the Housing Condition and the Residents' Preferences of the Suburban Housing Complexes)

  • 송빛나;주서령
    • 한국주거학회논문집
    • /
    • 제18권6호
    • /
    • pp.83-91
    • /
    • 2007
  • The purpose of this study is to understand the present housing condition of the suburban housing complex, and the residents' preferences to make their living condition better in Yong-in and Yang-pyeong, Pocheon, Kwang-ju and Kimpo in Kyung-Ki province, Korea. Questionnaire survey has been carried out to figure out the current status and residents' preferences of the Suburban housing complexes (hereafter SHC). The study showed the present status and the demands of people for their houses as a result like the below. First, currently the SHCs are managed by a joint control type, and the preferences of the residents' showed the similar way. Because of this status, the SHC planning is supposed to have the self-governing management and community space to support the activity of their community. Second, most SHCs doesn't have many public facility, in contrast, each house has various exteriors. This result shows the residents want more to develop their own houses' exterior than that of the SHC's public facility. Prior to plan the SHC, a program should be considered to give better understanding to residens what is the complexed life and make them choose what they really want to have. Third, the studied SHCs' renovation activities are commonly focussed on the exteriors. This shows the residents' life style is focussed more on the out-door life. The planning for the future SHC is supposed to have the points that could follow up the out-door friendly situations.

Prediction of moments in composite frames considering cracking and time effects using neural network models

  • Pendharkar, Umesh;Chaudhary, Sandeep;Nagpal, A.K.
    • Structural Engineering and Mechanics
    • /
    • 제39권2호
    • /
    • pp.267-285
    • /
    • 2011
  • There can be a significant amount of moment redistribution in composite frames consisting of steel columns and composite beams, due to cracking, creep and shrinkage of concrete. Considerable amount of computational effort is required for taking into account these effects for large composite frames. A methodology has been presented in this paper for taking into account these effects. In the methodology that has been demonstrated for moderately high frames, neural network models are developed for rapid prediction of the inelastic moments (typically for 20 years, considering instantaneous cracking, and time effects, i.e., creep and shrinkage, in concrete) at a joint in a frame from the elastic moments (neglecting instantaneous cracking and time effects). The proposed models predict the inelastic moment ratios (ratio of elastic moment to inelastic moment) using eleven input parameters for interior joints and seven input parameters for exterior joints. The training and testing data sets are generated using a hybrid procedure developed by the authors. The neural network models have been validated for frames of different number of spans and storeys. The models drastically reduce the computational effort and predict the inelastic moments, with reasonable accuracy for practical purposes, from the elastic moments, that can be obtained from any of the readily available software.

An experimental study on the effect of CFRP on behavior of reinforce concrete beam column connections

  • Xie, Qiang;Sinaei, Hamid;Shariati, Mahdi;Khorami, Majid;Mohamad, Edy Tonnizam;Bui, Dieu Tien
    • Steel and Composite Structures
    • /
    • 제30권5호
    • /
    • pp.433-441
    • /
    • 2019
  • The aim of this research is reinforcing of concrete with variety of fiber reinforced polymer (FRP) configurations and investigates the load capacity and ductility of these connections using an experimental investigation. Six scaled-down RC exterior joints were tested under moderately monotonic loads. The results show that, the shape of the FRP had a different effect on the joint capacity and the connection ductility coefficient. The greatest effect on increasing the ductility factor was seen in the sample where two reinforcement plates were used on both sides of the beam web (RCS5 sample). For the sample with the presence of FRP plates at the top and bottom of the beam (RCS3 sample), the ductility factor was reduced even the load capacity of this sample increased. Except for the RCS3 sample, the rest of the samples exhibited an increase in the ductility factor due to the FRP reinforcement.

Seismic performance of non-ductile detailing RC frames: An experimental investigation

  • Hidayat, Banu A.;Hu, Hsuan-Teh;Hsiao, Fu-Pei;Han, Ay Lie;Pita, Panapa;Haryanto, Yanuar
    • Earthquakes and Structures
    • /
    • 제19권6호
    • /
    • pp.485-498
    • /
    • 2020
  • Non-ductile detailing of Reinforced Concrete (RC) frames may lead to structural failure when the structure is subjected to earthquake response. These designs are generally encountered in older RC frames constructed prior to the introduction of the ductility aspect. The failure observed in the beam-column joints (BCJs) and accompanied by excessive column damage. This work examines the seismic performance and failure mode of non-ductile designed RC columns and exterior BCJs. The design was based on the actual building in Tainan City, Taiwan, that collapsed due to the 2016 Meinong earthquake. Hence, an experimental investigation using cyclic testing was performed on two columns and two BCJ specimens scaled down to 50%. The experiment resulted in a poor response in both specimens. Excessive cracks and their propagation due to the incursion of the lateral loads could be observed close to the top and bottom of the specimens. Joint shear failure appeared in the joints. The ductility of the member was below the desired value of 4. This is the minimum number required to survive an earthquake with a similar magnitude to that of El Centro. The evidence provides an understanding of the seismic failure of poorly detailed RC frame structures.

족 배 유리 피부판을 이용한 사지 재건술 (Reconstruction of the Extremities with the Dorsalis Pedis Free Flap)

  • 이준모;김문규
    • Archives of Reconstructive Microsurgery
    • /
    • 제8권1호
    • /
    • pp.77-83
    • /
    • 1999
  • 전북대학교병원 정형외과에서 1993년 8월부터 1997년 8월까지 족부 및 수부 손상 5례에 대하여 족 배 유리 피부판 이식술을 시행하고, 1999년 3월까지 최소 19개월부터 최장 67개월간 추시하여 다음과 같은 결과를 얻었다. 1. 나이별로는 9세부터 35세까지로 평균 23세 이었으며, 성별로는 전례가 남자이었으며, 족부에서 시행하였던 예가 4례, 수부에서 1례이었다. 2. 족부의 손상 원인은 교통사고 2례, 기계 사고 1례, 자전거 바퀴 사고 1례 이었으며, 수부에서는 교통사고에 의하여 전완부 요골의 개방성 골절이 동반되고 수부 배부의 다발성 신전 건 파열 및 피부 괴사에 의한 신전 건 노출 1례이었다. 3. 수여 동맥은 족 배 동맥 2례, 전 경골 동맥 1례, 후 경골 동맥 1례 그리고 척골 동맥이었으며, 수여 정맥은 족부 4례에서 2개 정맥을 문합하였으며, 5례(100%) 전례에서 성공하였다. 4. 추시 결과 유리 피판 이식술 후 외양(exterior)과 일상생활시 피부판이 손상되는 분쇄(maceration) 정도는 우수하였으나, 감각 회복 정토는 불량하였다. 5. 제공 부위인 족 배부는 유리 피판 이식술 3주 후 전층 식피술을 시행하여 완전 접착되었으며, 추시상 유병율없이 우수한 결과를 보였다.

  • PDF

복합모멘트접합을 갖는 콘크리트 충전 보-기둥 합성접합부의 반복하중 실험 (Cyclic Loading Tests of Concrete-Filled Composite Beam-Column Connections with Hybrid Moment Connections)

  • 임종진;김동관;이상현;이창남;엄태성
    • 한국강구조학회 논문집
    • /
    • 제28권5호
    • /
    • pp.345-354
    • /
    • 2016
  • 최근 합성 보-기둥 접합부를 위한 복합모멘트접합(hybrid moment connection)상세가 개발되었다. 기둥으로 팔각형태의 콘크리트 충전강관이 사용되었고, 보에는 U단면 콘크리트 충전강관이 사용되었다. 보-기둥 모멘트접합을 위해 보 강관은 기둥 강판에 직접 용접되었다. 하지만 보 하부 플랜지는 응력집중을 피하기 위하여 기둥 강판에 용접되지 않았고, 대신 보 플랜지의 인장력을 전달하기 위해 기둥 관통철근이 사용되었다. 기존 외다이어프램 보강상세 및 복합모멘트접합 상세를 갖는 총 4개의 실험체를 제작하고, 반복하중실험을 수행하였다. 실험결과 복합모멘트접합 상세는 보 플랜지의 인장력이 기둥 내부로 효과적으로 전달되었다. 또한, 하중재하능력 및 변형능력이 기존 외다이어프램 상세와 거의 동일한 수준으로 나타났다. 하지만, 최종 접합부 파괴모드는 복합모멘트접합 상세에 따라 영향을 받았다.

콜드조인트 및 재하 응력을 고려한 탄산화에 노출된 OPC 콘크리트의 확률론적 내구수명평가 (Probabilistic Service Life Evaluation for OPC Concrete under Carbonation Considering Cold Joint and Induced Stress Level)

  • 권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권6호
    • /
    • pp.45-52
    • /
    • 2019
  • 이산화탄소 농도가 높은 도심지의 경우 탄산화로 인한 철근부식이 발생하기 쉬우며 이는 콘크리트 구조물의 내구수명을 감소시킨다. 콘크리트 구조물의 경우 다양한 구속조건을 가지며 항상 외부의 재하하중을 받고 있다. 도입된 응력수준은 이산화탄소와 같은 유해인자의 확산을 변화시키며 탄산화 깊이의 변동성을 야기한다. 본 연구에서는 응력재하수준에 따른 탄산화 변동성을 정량화하였으며, 이를 이용하여 탄산화 예측식을 도출하였다. 내구성 설계인자인 피복두께, 이산화탄소 확산계수, 탄산화 반응 수화물, 그리고 외부 이산화탄소 농도를 확률변수로 정의하였으며, MCS을 통하여 영향인자의 변동성에 따른 내구수명을 도출하였다. 또한 응력수준에 따라 변화하는 내구수명을 도출하였으며, 이를 결정론적인 방법의 결과와 비교하였다. 피복두께 및 내부 수화물 생성이 내구수명 변동성에 가장 큰 영향을 미쳤으며, 응력수준을 고려한 내구수명평가는 유지관리 우선순위 설정에 합리적으로 적용할 수 있다.

Experiments on reinforced concrete beam-column joints under cyclic loads and evaluating their response by nonlinear static pushover analysis

  • Sharma, Akanshu;Reddy, G.R.;Eligehausen, Rolf;Vaze, K.K.;Ghosh, A.K.;Kushwaha, H.S.
    • Structural Engineering and Mechanics
    • /
    • 제35권1호
    • /
    • pp.99-117
    • /
    • 2010
  • Beam-column joints are the key structural elements, which dictate the behavior of structures subjected to earthquake loading. Though large experimental work has been conducted in the past, still various issues regarding the post-yield behavior, ductility and failure modes of the joints make it a highly important research topic. This paper presents experimental results obtained for eight beam-column joints of different sizes and configuration under cyclic loads along with the analytical evaluation of their response using a simple and effective analytical procedure based on nonlinear static pushover analysis. It is shown that even the simplified analysis can predict, to a good extent, the behavior of the joints by giving the important information on both strength and ductility of the joints and can even be used for prediction of failure modes. The results for four interior and four exterior joints are presented. One confined and one unconfined joint for each configuration were tested and analyzed. The experimental and analytical results are presented in the form of load-deflection. Analytical plots are compared with envelope of experimentally obtained hysteretic loops for the joints. The behavior of various joints under cyclic loads is carefully examined and presented. It is also shown that the procedure described can be effectively utilized to analytically gather the information on behavior of joints.

Cyclic performance and design recommendations of a novel weak-axis reduced beam section connection

  • Lu, Linfeng;Xu, Yinglu;Liu, Jie;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제27권3호
    • /
    • pp.337-353
    • /
    • 2018
  • In previous weak-axis moment connection tests, brittle fracture always initiated near the edge of the beam flange groove weld due to force flow towards the stiffer column flanges, which is the opposite pattern as strong-axis moment connections. As part of the China NSFC (51278061) study, this paper tested two full-scale novel weak-axis reduced beam section moment connections, including one exterior frame connection specimen SJ-1 under beam end monotonic loading and one interior frame joint specimen SJ-2 under column top cyclic loading. Test results showed that these two specimens were able to satisfy the demands of FEMA-267 (1995) or ANSI/AISC 341-10 (2010) without experiencing brittle fracture. A parametric analysis using the finite element software ABAQUS was carried out to better understand the cyclic performance of the novel weak-axis reduced beam section moment connections, and the influence of the distance between skin plate and reduced beam section, a, the length of the reduced beam section, b, and the cutting depth of the reduced beam section, c, on the cyclic performance was analyzed. It was found that increasing three parametric values reasonably is beneficial to forming beam plastic hinges, and increasing the parameter a is conducive to reducing stress concentration of beam flange groove welds while increasing the parameters b and c can only reduce the peak stress of beam flange groove welds. The rules recommended by FEMA350 (2000) are suitable for designing the proposed weak-axis RBS moment connection, and a proven calculation formulation is given to determine the thickness of skin plate, the key components in the proposed weak-axis connections. Based on the experimental and numerical results, a design procedure for the proposed weak-axis RBS moment connections was developed.