Cyclic Loading Tests of Concrete-Filled Composite Beam-Column Connections with Hybrid Moment Connections

복합모멘트접합을 갖는 콘크리트 충전 보-기둥 합성접합부의 반복하중 실험

  • Received : 2016.06.09
  • Accepted : 2016.08.25
  • Published : 2016.10.27

Abstract

In the present study, hybrid moment connections of welding and bar reinforcement for composite beam-column connections were proposed. Concrete-filled octagonal tube and U-section were used for the column and beam, respectively. In the beam-column connection, the top flange and web of the beam U-section were connected to the column plate by welding. However, to reduce stress concentration at the weld joints, the bottom flange of the beam was not welded to the column plate. Instead, to transfer the tension force of the beam flange, reinforcing bars passing through the column plate were used. Four exterior connections with conventional welded and hybrid moment connections were tested under cyclic loading and their cyclic behaviors were investigated. The test results showed that the hybrid moment connections successfully transferred the beam moment to the column. The strength and ductility of the hybrid moment connections were comparable to the conventional welded moment connection with exterior diaphragm; however, the connection performance was significantly affected by the details of the hybrid moment connection.

최근 합성 보-기둥 접합부를 위한 복합모멘트접합(hybrid moment connection)상세가 개발되었다. 기둥으로 팔각형태의 콘크리트 충전강관이 사용되었고, 보에는 U단면 콘크리트 충전강관이 사용되었다. 보-기둥 모멘트접합을 위해 보 강관은 기둥 강판에 직접 용접되었다. 하지만 보 하부 플랜지는 응력집중을 피하기 위하여 기둥 강판에 용접되지 않았고, 대신 보 플랜지의 인장력을 전달하기 위해 기둥 관통철근이 사용되었다. 기존 외다이어프램 보강상세 및 복합모멘트접합 상세를 갖는 총 4개의 실험체를 제작하고, 반복하중실험을 수행하였다. 실험결과 복합모멘트접합 상세는 보 플랜지의 인장력이 기둥 내부로 효과적으로 전달되었다. 또한, 하중재하능력 및 변형능력이 기존 외다이어프램 상세와 거의 동일한 수준으로 나타났다. 하지만, 최종 접합부 파괴모드는 복합모멘트접합 상세에 따라 영향을 받았다.

Keywords

References

  1. 이성희, 김영호, 최성모(2016) 용접조립 각형 CFT 기둥-보 외다이어프램 접합부의 구조거동, 한국강구조학회논문집, 한국강구조학회, 제28권, 제2호, pp.75-83. (Lee S.H., Kim Y.H., and Choi, S.M. (2016) Structural Behavior of Welded Built-up Square CFT Column to Beam Connections with External Diaphragm, Journal of Korean Society of Steel Construction, KSSC, Vol.28, No.2, pp.75-83 (in Korean).)
  2. 박종원, 강승민, 김욱종(2003) 사각판 스티프너로 보강한 콘크리트 충전강관 기둥과 H-형강 보 접합부의 내진성능, 한국강구조학회논문집, 한국강구조학회, 제15권, 제2호, pp.167-175. (Park J.W., Kang S.M., and Kim, W.J. (2003) Seismic Performance of Wide Flange Beam-to-Column Filled Tube Column Joints with Stiffening Plates around the Column, Journal of Korean Society of Steel Construction, KSSC, Vol.15, No.2, pp.167-174 (in Korean).)
  3. Shin K.J., Kim Y.J., Oh Y.S., and Moon T.S. (2004) Behavior of welded CFT column to H-beam connections with external stiffeners, Journal of Engineering Structures, Vol.26, No.13, pp.1877-1887. https://doi.org/10.1016/j.engstruct.2004.06.016
  4. C.-C. Chen., C.-C. Lin., and C.-L. Tsai (2004) Evaluation of reinforced between steel beams and box columns, Journal of Engineering Structures, Vol.26, pp.1889-1904. https://doi.org/10.1016/j.engstruct.2004.06.017
  5. Shanmugan, N.E., Ting, L.C., and Lee, S.L. (1991) Behavior of I-beam to box-column connections stiffened externally and subjected to fluctuating loads, Journal of Constructional Steel Research, Vol.20, No.2, pp.129-148. https://doi.org/10.1016/0143-974X(91)90016-T
  6. 김영주, 배재훈, 안태상, 김진원, 유홍식(2014) SRC기둥-H형단면과 U형단면으로 구성된 합성보 접합부의 반복가력실험, 한국강구조학회논문집, 한국강구조학회, 제26권, 제4호, pp.263-275. (Kim Y.J., Bae J.H., Ahn T.S., Kim J.W., and Ryu H.S. (2014) Cyclic Loading Test on Composite of SRC Column-Composite Beam Consisting of H-Section and U-Section Members, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.4, pp.263-275 (in Korean).)
  7. 강해관(2002) 사각판 스티프너로 보강한 콘크리트 충전 각형강관 기둥- H 형강 보 접합부 연구, 박사학위논문, 서울대학교. (Kang H.G. (2002) Wide Flange Beam to Concrete Filled Rectangular Tube Column Joints with Stiffening Plates around the Column, Ph.D. Dissertation, Seoul National University, Korea (in Korean).)
  8. Beutel, J., Thambiratnam, D., and Perera, N. (2002) Cyclic behavior of concrete filled steel tubular column to steel beam connections, Journal of Engineering Structures, Vol.24, No.1, pp.29-38. https://doi.org/10.1016/S0141-0296(01)00083-9
  9. Alostaz, Y.M. and Schneider, S.P. (1996) Connections to concrete-filled steel tubes, A report on research sponsored by the National Science Foundation, University of Illinois at Urbana-Champaign, Illinois.
  10. Azizinamini, A. and Prakash, B. (1993) A tentative Design Guidelines for a New Steel Beam Connection Detail to Composite Tube Columns, AISC Engineering Journal, 3rd quarter, pp.108-115.
  11. Mirghaderi, S.R., Torabian, S., and Keshavarzi, F. (2010) I-beam to box-column connection by a vertical plate passing through the column, Journal of Engineering Structures, Vol.32, No.8, pp.2034-2048. https://doi.org/10.1016/j.engstruct.2010.03.002
  12. Korea Concrete Institute, Design Code for Concrete Structures, KCI, 2012 (in Korean).)
  13. America Institute of Steel Construction (AISC), Specification for Structural Steel Buildings, ANSI/AISC 360-10, Chicago, 2010.
  14. America Institute of Steel Construction (AISC), Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications, ANSI/AISC 358-10, Chicago, 2010.
  15. The Europen Standard, Eurocode 8, Design of structures for earthquake resistance, BS EN 1988-1:2004, 2004.
  16. 이철호, 정종현, 김정재(2014) 철골모멘트 용접접합부의 내진성능에 미치는 합성슬래브의 영향, 한국강구조학회논문집, 한국강구조학회, 제26권, 제5호, pp.385-396. (Lee C.H., Jung J.H., and Kim, J.J. (2014) Effects of Composite Floor Slab on Seismic Performance of Welded Steel Moment Connections, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.5, pp.385-396 (in Korean).)

Cited by

  1. Experimental Investigation of Bolted Splice for Concrete-Filled Thin-Walled Tube Columns vol.31, pp.4, 2016, https://doi.org/10.7781/kjoss.2019.31.4.261
  2. Behavior of End Plate Moment Connection with Through Bolts for Concrete Filled Composite Members with Thin-Walled Sections vol.32, pp.6, 2016, https://doi.org/10.7781/kjoss.2020.32.6.405