• Title/Summary/Keyword: Exposure to Radioactivity

Search Result 107, Processing Time 0.032 seconds

The Study on the Implementation of the X-Ray CT System Using the Cone-Beam for the 3D Dynamic Image Acquisition (3D 동영상획득을 위한 Cone-Beam 형 X-Ray CT 시스템 구현에 관한 연구)

  • Jeong, Chan-Woong;Jun, Kyu-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.370-374
    • /
    • 2009
  • In this paper, we presents a new cone beam computerized tomography (CB CT) system for the reconstruction of 3 dimensional dynamic images. The system using cone beam has less the exposure of radioactivity than fan beam, relatively. In the system, the reconstruction 3-D image is reconstructed with the radiation angle of X-ray in the image processing unit and transmitted to the monitor. And in the image processing unit, the Three Pass Shear Matrices, a kind of Rotation-based method, is applied to reconstruct 3D image because it has less transcendental functions than the one-pass shear matrix to decrease a time of calculations for the reconstruction 3-D image in the processor. The new system is able to get 3~5 3-D images a second, reconstruct the 3-D dynamic images in real time.

Radiation Analysis by Chemical Treatment of Agricultural Products in Environmental Samples (환경시료 중 농산물에서 화학적 처리 방법에 의한 방사능 분석)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.531-538
    • /
    • 2017
  • Agricultural products produced in the agricultural area around the nuclear power plant are radioactive contamination, which can cause radioactive contamination to the human body. The purpose of this study was to investigate the limit of the radioactivity concentration $^{90}Sr$ for the internal exposure dose evaluation by ingesting the agricultural products collected around the nuclear power plant. The results of the gamma-isotope element analysis were freshly <0.0166-0.0336 Bq / kg for all samples and for artificial radionuclides not detected, and fresh <0.00586-0.0421 Bq / kg for Chinese cabbage, The freshness was 0.106 Bq / kg, and the freshness was 0.0114-0.0901 Bq / kg. 0.0177%, 0.0222%, 0.0376% and 0.00243%, respectively, for Chinese cabbages and large roots, which is lower than the legal standard value of $1mSv/yr{\cdot}man%$. It is considered that the formulas need to be broadly evaluated for the foods consumed by children and adults, taking into consideration the age of the food and the diet

Protease Inhibitors in Porcine Colostrum: Potency Assessment and Initial Characterization

  • Zhou, Q.;He, R.G.;Li, X.;Liao, S.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.12
    • /
    • pp.1822-1829
    • /
    • 2003
  • Porcine colostrum and milk were separated into the acid-soluble and casein fractions by acidification followed by centrifuge. The acid-soluble fraction of porcine colostrum was further separated by liquid chromatography and anisotropic membrane filtration. Trypsin and chymotrypsin inhibitory capacity in porcine colostrum, milk and their components was determined by incubating bovine trypsin or chymotrypsin in a medium containing their corresponding substrates with or without addition of various amounts of porcine colostrum, porcine milk or their components. The inhibition of insulin-like growth factor I (IGF-I) and epidermal growth factor (EGF) degradation in pig small intestinal contents by porcine colostrum was measured by incubating iodinated IGF-I or EGF with the intestinal contents with or without addition of porcine colostrum. Degradation of labeled IGF-I or EGF was determined by monitoring the generation of radioactivity soluble in 30% trichloroacetic acid (TCA). The results showed that porcine colostrum had high levels of trypsin and chymotrypsin inhibitory activity and increased the stability of IGF-I and EGF in pig intestinal contents. The inhibitory activity declined rapidly during lactation. It was also found that trypsin and chymotrypsin inhibitory activity and the inhibition on IGF-I and EGF degradation in the acid-soluble fraction were higher than that in the casein fraction. Heat-resistance study indicated that trypsin inhibitors in porcine colostrum survived heat treatments of $100^{\circ}C$ water bath for up to 10 min, but exposure to boiling water bath for 30 min significantly decreased the inhibitory activity. Compared with the trypsin inhibitors, the chymotrypsin inhibitors were more heatsensitive. Separation of the acid-soluble fraction of porcine colostrum by liquid chromatography and anisotropic membrane filtration revealed that the trypsin and chymotrypsin inhibitory capacity was mainly due to a group of small proteins with molecular weight of 10,000-50,000. In conclusion, the present study confirmed the existence of high levels of protease inhibitors in porcine colostrum, and the inhibition of porcine colostrum on degradation of milk-borne growth factors in the pig small intestinal tract was demonstrated for the first time.

Performance test of urine bioassay through participation in the NRIP (NRIP 참여를 통한 소변시료 바이오어세이 성능검사)

  • Ha, Wi-Ho;Yoo, Jaeryong;Yoon, Seokwon;Lee, Seung-Sook;Kim, Jong Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.96-102
    • /
    • 2014
  • Urine bioassay has been widely used for internal dosimetry due to simple process of sampling and measurement. In this paper, we participated in the NRIP (NIST Radiochemistry Intercomparison Program) hosted by US NIST to carry out a reliable performance test of urine bioassay and introduced the measurement method and results of NRIP-2013. In customary exercise with 60 days of reporting time, bioassay results of 12 radionuclides in the synthetic urine samples were acceptable based on the performance criteria of ANSI N13.30. In emergency preparedness exercise with 8 hours of reporting time, bioassay results of 9 radionuclides showed that differences ranged from -35% to 45%. However, we concluded that urine bioassay applied for emergency preparedness exercise would be applicable for rapid screening and estimation of internal exposure within a difference of ${\pm}45%$ in the event of radiological accidents.

The Algorithm Improved the Speed for the 3-Dimensional CT Video Composition (3D CT 동영상 구성을 위한 속도 개선 알고리즘)

  • Jeong, Chan-Woong;Park, Jin-Woo;Jun, Kyu-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.141-147
    • /
    • 2009
  • This paper presents a new fast algorithm, rotation-based method (RBM), for the reconstruction of 3 dimensional image for cone beam computerized tomography (CB CT) system. The system used cone beam has less exposure time of radioactivity than fan beam. The Three-Pass Shear Matrices (TPSM) is applied, that has less transcendental functions than the one-pass shear method to decrease a time of calculations in the computer. To evaluate the quality of the 3-D images and the time for the reconstruction of the 3-D images, another 3-D images were reconstructed by the radon transform under the same condition. For the quality of the 3-D images, the images by radon transform was shown little good quality than REM. But for the time for the reconstruction of the 3-D images REM algorithm was 35 times faster than radon transform. This algorithm offered $4{\sim}5$ frames a second. It meant that it will be possible to reconstruct the 3-D dynamic images in real time.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

The Study of Radiation Exposure Reduction by Developing Corpus Striatum Phantom (두개골-선조체 팬텀을 이용한 선량 저감화 방안 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.595-603
    • /
    • 2017
  • The study is to produced a brain phantom simulating corpus striatum, which can evaluate the progression of parkinson's disease, to investigate possibility of reducing the brain exposure dose to CT while maintaining optimal image quality during PET-CT examinations. CT scans were performed by varying tube voltage (100, 120 kVp) and tube current (80, 140, 200 mAs) with $^{18}F$ FP-CIT injected into the phantom's hot sphere and background (radioactivity ratio 3:1)(reference condition; 120 kVp, 140 mAs). Estimated effective dose was calculated by using conversion factor according to each condition, and image quality was evaluated by setting SNR and CRChot image evaluation factors. Experimental results showed that the predicted effective dose below the CT imaging reference condition was reduced by at least 10% and by up to 60%, and the predicted effective dose beyond the reference condition was increased by 40%. In addition, there was no significant difference between SNR and CRChot of PET images, and it was confirmed that brain dose decreased with decrease of tube voltage and tube current. At the same time, there was no significant change in the quality of the image in terms of SNR and CRChot despite the change in scan conditions. This fact suggests that the quality of the images acquired under the existing dose conditions can be obtained even at low dose conditions and it is expected that it will be possible to use the brain PET-CT scan as a basic data for the research on reduction of dose and improvement of image quality.

Behavior of the herbicide metolachlor in carps (제초제 metolachlor의 잉어체내 행적)

  • Kyung, Kee-Sung;Kim, Jin-Wha;Lee, Byung-Moo;Oh, Byung-Youl;Jeong, Young-Ho;Lee, Jae-Koo
    • The Korean Journal of Pesticide Science
    • /
    • v.3 no.2
    • /
    • pp.54-59
    • /
    • 1999
  • In order to investigate the behavior of the herbicide metolachlor [2-chloro-6'-ethyl-N-(2-methoxy-1-methylethyl)aceto-O-toluidide] in fish, carps (Cyprinus carpio L.) were exposed to the herbicide at $LC_{10}$(1.93 mg/L) for 4 days. Metolachlor dissolved in water was absorbed rapidly into carps to mark the maximum concentration 6 hours after exposure. The amounts of the $^{14}C$-metolachlor and its metabolites absorbed in gall were much higher than those in the other parts, strongly suggesting that biliary excretion involving enterohepatic recirculation could be an important route for the elimination of metolachlor. The $^{14}C$-radioactivity distributed into aqueous phase fraction in test water and in carp extract was increased in time-dependent manner. Extraction rate of $^{14}C$ absorbed in carp tissues was decreased remarkably up to 6 hours after exposure, suggesting that the possible polar metabolites of metolachlor were transformed into the conjugates to form non-extractable bound residues.

  • PDF

Safety Evaluation of Clearance of Radioactive Metal Waste After Decommissioning of NPP (원전해체후 규제해제 대상 금속폐기물에 대한 자체처분 안전성 평가)

  • Choi, Young-Hwan;Ko, Jae-Hun;Lee, Dong-Gyu;Hwang, Young-Hwan;Lee, Mi-Hyun;Lee, Ji-Hoon;Hong, Sang-Bum
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.291-303
    • /
    • 2020
  • The Kori-Unit 1 nuclear power plant, which is scheduled to be decommissioned after permanent shutdown, is expected to generate large amounts of various types of radioactive waste during the decommissioning process. Among these, nuclear reactors and internal structures have high levels of radioactivity and the dismantled structure must have the proper size and weight on the primary side. During decommissioning, it is important to prepare an appropriate and efficient disposal method through analysis of the disposal status and the legal restrictions on wastes generated from the reactors and internal structures. Nuclear reactors and internal structures generate radioactive wastes of various levels, such as medium, very low, and clearance. A radiation evaluation indicates that wastes in the clearance level are generated in the reactor head and upper head insulation. In this study, a clearance waste safety evaluation was conducted using the RESRAD-RECYCLE code, which is a safety evaluation code, based on the activation evaluation results for the clearance level wastes. The clearance scenario for the target radioactive waste was selected and the maximum individual and collective exposure doses at the time of clearance were calculated to determine whether the clearance criteria limit prescribed by the Nuclear Safety Act was satisfied. The evaluation results indicated that the doses were significantly low, and the clearance criteria were satisfied. Based on the safety assessment results, an appropriate metal recycle and disposal method were suggested for clearance, which are the subject of the deregulation of internal structures of nuclear power plant.

The Experience on Intake Estimation and Internal Dose Assessment by Inhalation of Iodine-131 at Korean Nuclear Power Plants (국내 원전에서 $^{131}I$ 내부 흡입 에 따른 섭취량 산정과 내부피폭 방사선량 평가 경험 몇 개선방향에 대한 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.129-136
    • /
    • 2009
  • During the maintenance period at Korean nuclear power plants, internal exposure of radiation workers occurred by the inhalation of $^{131}I$ released to the reactor building when primary system opened. The internal radioactivity of radiation workers contaminated by $^{131}I$ was measured using a whole body counter. Intake estimation and the calculation of committed effective dose were also conducted conforming to the guidance of internal dose assessments from publications of International Commission on Radiological Protection. Because the uptake and excretion of $^{131}I$ in a body occur quickly and $^{131}I$ is accumulated in the thyroid gland, the estimated intakes showed differences depending on the counting time after intake. In addition, since ICRP publications do not provide the intake retention fraction (IRF) for whole body of $^{131}I$, the IRF for thyroid was substitutionally used to calculate the intake and subsequently this caused more error in intake estimation. Thus, intake estimation and the calculation of committed effective dose were conducted by manual calculation. In this study, the IRF for whole body was also calculated newly and was verified. During this process, the estimated intake and committed effective dose were reviewed and compared using several computer codes for internal dosimetry.