• Title/Summary/Keyword: Exposure fire

Search Result 266, Processing Time 0.026 seconds

Fire-Resistance Characteristics of Shield Tunnel Concrete Linings (쉴드터널 콘크리트 라이닝의 내화특성)

  • Park Hae Geun;Lee Myeong Sub;Jeon Sang Eun;Park Dong Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.32-35
    • /
    • 2004
  • In recent years a number of catastrophic tunnel fires, the Euro tunnel, the Mont Blanc tunnel, the Tauem tunnel and the Gotthard tunnel, have occurred and inflicted serious damages to European countries. If a fire occurs in shield tunnels, the reinforced concrete segment linings playing as an important structural member is expected to damage severely and finally can be caused the collapse of tunnel. The purpose of this study is to evaluate the performance of concrete segment lining under heat exposure and to obtain information to assist a new technical approach to fighting fires in tunnels. In order to evaluate the fire-resistance performance of concrete segment by adding Polypropylene fibers, fire tests using the RABT heat-load curve is carried out. The temperature rise of this curve is very rapid up to $1200^{\circ}C$ within 5 minutes, and duration time of the $1200^{\circ}C$ exposure is 55 minutes. From the fire test, it was found that the explosive spalling was rapidly reduced by adding polypropylene fibers and this method is considered as an effective fireproof material to upgrade fire safety in tunnels economically.

  • PDF

Residual strength of spalled high-performance concrete members subjected to fire (화재시 고강도 콘크리트 부재의 폭렬성상에 따른 잔존강도)

  • Choi, Eun-Gyu;Shin, Yeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.941-944
    • /
    • 2008
  • This study is aimed to investigate the residual strength of fire damaged high-performance concrete flexural and compressive members. The compressive strength of specimens is 55MPa and the main parameter for comparison is the exposure time to fire. In case of beams, the cover thickness made the differences in spalled section area, residual strength and serviceability. The exposure time to fire did not affect on the spalled section area in case of compressive members without loading. However, the residual strength and stiffness was reduced by the time exposed to fire. This study can be used to estimate the performance of fire damaged high-strength concrete structural members for reusing and to give the information for repairing and strengthening.

  • PDF

Reliability studies on RC beams exposed to fire based on IS456:2000 design methods

  • Balaji, Aneesha;Aathira, M.S.;Pillai, T.M. Madhavan;Nagarajan, Praveen
    • Structural Engineering and Mechanics
    • /
    • v.59 no.5
    • /
    • pp.853-866
    • /
    • 2016
  • This paper examines a methodology for computing the probability of structural failure of reinforced concrete beams subjected to fire. The significant load variables considered are dead load, sustained live load and fire temperature. Resistance is expressed in terms of moment capacity with random variables taken as yield strength of steel, concrete class (or grade of concrete), beam width and depth. The flexural capacity is determined based on the design equations recommended in Indian standard IS456:2000. Simplified method named $500^{\circ}C$ isotherm method detailed in Eurocode 2 is incorporated for fire design. A transient thermal analysis is conducted using finite element software ANSYS$^{(R)}$ Release15. Reliability is evaluated from the initial state to 4h of fire exposure based on the first order reliability method (FORM). A procedure is coded in MATLAB for finding the reliability index. This procedure is validated with available literature. The effect of various parameters like effective cover, yield strength of steel, grade of concrete, distribution of reinforcement bars and aggregate type on reliability indices are studied. Parameters like effective cover of concrete, yield strength of steel has a significant effect on reliability of beams. Different failure modes like limit state of flexure and limit state of shear are checked.

Performance of Adhesives in Glulam after Short Term Fire Exposure

  • Quiquero, Hailey;Chorlton, Bronwyn;Gales, John
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.299-311
    • /
    • 2018
  • As engineered timber such as Glulam is seeing increasing use in tall timber buildings, building codes are adapting to allow for this. In order for this material to be used confidently and safely in one of these applications, there is a need to understand the effects that fire can have on an engineered timber structural member. The post-fire resilience aspect of glulam is studied herein. Two sets of experiments are performed to consider the validity of zero strength guidance with respect to short duration fire exposure on thin glulam members. Small scale samples were heated in a cone calorimeter to different fire severities. These samples illustrated significant strength loss but high variability despite controlled quantification of char layers. Large scale samples were heated locally using a controlled fuel fire in shear and moment locations along the length of the beam respectively. Additionally, reduced cross section samples were created by mechanically carving a way an area of cross section equal to the area lost to char on the heated beams. All of the samples were then loaded to failure in four-point (laterally restrained) bending tests. The beams that have been burnt in the shear region were observed as having a reduction in strength of up to 34.5% from the control beams. These test samples displayed relatively little variability, apart from beams that displayed material defects. The suite of testing indicated that zero strength guidance may be under conservative and may require increasing from 7 mm up to as much as 23 mm.

Evaluation on the Thermal Resistance Capacity of Fire Proof Materials for Improving Fire Resistance of Near-Surface-Mounted FRP in Concrete (콘크리트내에 표면매입 보강된 FRP의 내화성능 향상을 위한 내화단열재 열저항성능 평가)

  • Yeon, Jea-Young;Seo, Soo-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.51-58
    • /
    • 2014
  • This paper presents a fire exposure test result to evaluate fire resistance capacity of retrofit method using FRP (Fiber Reinforced Polymer) in reinforcement concrete structure. Especially, this paper focused on near-surface-mounted retrofit method; FRP is mounted into the groove after making a groove in concrete. In the test, main parameters are retrofit method and materials for fire proofing. Spray type of perlite and board type of calcium silicate were considered as external fire proof on surface while particle of calcium silicate and polymer mortar as internal one in groove. By increasing the temperature of inside heating furnace, the transfer of temperature from surface of fire proofing material to groove in specimen was measured. As a result, fire proofing using the board of calcium silicate was more effective to delay the heat transfer from outside than spraying with perlite. It was found that the fire proofing could resist outside temperature of $820^{\circ}C$ at maximum to keep the temperature of epoxy below glass transit temperature (GTT).

Strength Properties of RC Slabs under Elevated Temperatures from Fire (화재시 온도증가로 인한 RC 슬래브의 강도 특성)

  • Im, Cho-Rong;Chung, Chul-Hun;Kim, Yu-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.48-60
    • /
    • 2010
  • The fire resistance performance of 2 RC slabs after exposure to the ISO-834 fire standard without loading has been experimentally investigated. A Comparison is made of the fire resistance performance between RC slabs without PP(polypropylene) fibers and RC slabs with PP fibers. From the fire test results, the presence of PP fibers in RC slabs can reduce spalling and enhance their fire resistance. Until now, the determination of fire resistance of reinforced concrete(RC) slabs has essentially been based on tabulated data. According to ACI 216 code and EUROCODE 2, the design of concrete structures is essentially based on tabulated data for appropriate concrete cover and various fire durations. From the comparison between fire test results and codes, current fire design provisions of codes such as the ACI 216 and the EUROCODE 2 are unconservative for estimating mechanical properties of RC slabs at elevated temperatures.

Latest passenger vehicle fire trend and case study based on field investigation data (차량화재 사고경향 및 사례분석)

  • Shin, Junho;Won, Eugene;Hong, Ilmin
    • Journal of Auto-vehicle Safety Association
    • /
    • v.6 no.2
    • /
    • pp.67-71
    • /
    • 2014
  • Based on the analysis of the actual passenger vehicle fire cases for recent four years (2010~2013), the passenger vehicle fire is increasing annually. Main root cause was analyzed as an electric problem as a 39%. Vehicle fire case by electric problem was mainly caused by use of Non-genuine part. Vehicle fire case by mechanical problem was mainly caused by various oil system maintenance. Vehicle fire case by smoking material was mainly caused by cigarette and disposal lighter. And external fire transition issue and towing mistake fire cases was also confirmed.

Synthesizing and Assessing Fire-Resistant Geopolymer from Rejected Fly Ash

  • An, Eung-Mo;Cho, Young-Hoon;Chon, Chul-Min;Lee, Dong-Gyu;Lee, Sujeong
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.4
    • /
    • pp.253-263
    • /
    • 2015
  • Ordinary Portland cement is a widely favored construction material because of its good strength and durability and its reasonable price; however, spalling behaviour during fire exposure can be a serious risk that can lead to strength degradation or collapse of a building. Geopolymers, which can be synthesized by mixing aluminosilicate source materials such as metakaolin and fly ash, and alkali activators, are resistant to fire. Because the chemical composition of geopolymers controls the properties of the geopolyers, geopolymers with various Si:Al ratios were synthesized and evaluated as fire resistant construction materials. Rejected fly ash generated from a power plant was quantitatively analyzed and mixed with alkali activators to produce geopolymers having Si:Al ratios of 1.5, 2.0, and 3.5. Compressive strength of the geopolymers was measured at 28 days before and after heating at $900^{\circ}C$. Geopolymers having an Si:Al ratio of 1.5 presented the best fire resistance, with a 44% increase of strength from 29 MPa to 41 MPa after heating. This material also showed the least expansion-shrinkage characteristics. Geopolymer mortar developed no spalling and presented more than a 2 h fire resistance rating at $1,050^{\circ}C$ during the fire testing, with a cold side temperature of $74^{\circ}C$. Geopolymers have high potential as a fire resistant construction material in terms of their increased strength after exposure to fire.

Study on the Safety Standard Establishment of Halogen Clean Extinguishing Agents (할로겐화합물청정소화약제 안전기준 설정에 관한 연구)

  • Cho, Jung-Rae;Lee, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.22-33
    • /
    • 2018
  • The amount of halogen clean fire extinguishing agents has been increased by the excellent features of extinguishing, adaptability and no residue. On the other hand in situations without a hazard assessment and safety standard of agents, chemical accidents by the agents occurs frequently. This study was performed to propose the halogen clean agents' regulatory exposure limit and safety standard including the quantitative ventilation system with gas leak monitoring, hazard recognition and optimal personal protection selection through a literature review and experimental research.

Exposure to elevated temperatures and cooled under different regimes-a study on polypropylene concrete

  • Yaragal, Subhash C.;Ramanjaneyulu, S.
    • Advances in materials Research
    • /
    • v.5 no.1
    • /
    • pp.21-34
    • /
    • 2016
  • Fire is one of the most destructive powers to which a building structure can be subjected, often exposing concrete elements to elevated temperatures. The relative properties of concrete after such an exposure are of significant importance in terms of the serviceability of buildings. Unraveling the heating history of concrete and different cooling regimes is important for forensic research or to determine whether a fire-exposed concrete structure and its components are still structurally sound or not. Assessment of fire-damaged concrete structures usually starts with visual observation of colour change, cracking and spalling. Thus, it is important to know the effect of elevated temperatures on strength retention properties of concrete. This study reports the effect of elevated temperature on the mechanical properties of the concrete specimen with polypropylene fibres and cooled differently under various regimes. In the heating cycle, the specimen were subjected to elevated temperatures ranging from $200^{\circ}C$ to $800^{\circ}C$, in steps of $200^{\circ}C$ with a retention period of 1 hour. Then they were cooled to room temperature differently. The cooling regimes studied include, furnace cooling, air cooling and sudden cooling. After exposure to elevated temperatures and cooled differently, the weight loss, residual compressive and split tensile strengths retention characteristics were studied. Test results indicated that weight and both compressive and tensile strengths significantly reduce, with an increase in temperature and are strongly dependent on cooling regimes adopted.