• Title/Summary/Keyword: Exposure System

Search Result 2,357, Processing Time 0.033 seconds

Design of Projection Optics System for FPD Exposure (FPD Exposure System 용 투영광학계 설계)

  • 배상신;정연욱;김용래;송청호;송준엽;김동훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1290-1294
    • /
    • 2004
  • Exposure System is used for printing a prescribed pattern on a printed board, a liquid crystal substrate or the like. In this paper we are trying to develop projection Optics Exposure System for manufacturing Color Filter of LCD Display. This paper explain the Projection Optics Design and Illumination Optics Design of Color Filter Exposure system.

  • PDF

Deep Learning Machine Vision System with High Object Recognition Rate using Multiple-Exposure Image Sensing Method

  • Park, Min-Jun;Kim, Hyeon-June
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.76-81
    • /
    • 2021
  • In this study, we propose a machine vision system with a high object recognition rate. By utilizing a multiple-exposure image sensing technique, the proposed deep learning-based machine vision system can cover a wide light intensity range without further learning processes on the various light intensity range. If the proposed machine vision system fails to recognize object features, the system operates in a multiple-exposure sensing mode and detects the target object that is blocked in the near dark or bright region. Furthermore, short- and long-exposure images from the multiple-exposure sensing mode are synthesized to obtain accurate object feature information. That results in the generation of a wide dynamic range of image information. Even with the object recognition resources for the deep learning process with a light intensity range of only 23 dB, the prototype machine vision system with the multiple-exposure imaging method demonstrated an object recognition performance with a light intensity range of up to 96 dB.

The Adoption of Risk Assessment Methodology in Exposure Assessment (근로자 노출평가제도 내 위험성평가 방법론의 적용)

  • Kim, Seung Won;Choi, Sangjun;Phee, Young Gyu;Kim, Kab Bae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.482-492
    • /
    • 2015
  • Objectives: Exposure Assessment for workplace hazards where the exposure level is below occupational exposure limits(OELs) has been performed without considering either the degrees of risk or exposure levels and has failed to lead to intervention in many cases. The objective of this study was to suggest and test an application framework for risk assessment methodology under the current exposure assessment system in Korea. Materials: First, we investigated the exposure assessment systems in Korea and other countries. To adopt some risk assessment techniques, we also analyzed risk assessment systems and compared them to exposure assessment systems. A few suggestions were made. We held a public hearing during an industrial hygiene conference and took surveys using a questionnaire. Results: The first suggestion was to implement the risk assessment and exposure assessment through a "one-stop" system. In that case, one expected question would be who has been doing the jobs so far. In most cases, industrial hygiene consulting services or laboratories have been performing exposure assessment for business owners. Business owners are required to perform risk assessment. As two different groups of people will be required to implement two things in a one-stop system, they need to share information. As an information vehicle to share information, commonly filed survey checklists were suggested. The second suggestion was to categorize exposure level into four groups instead of the current binary divisions based on OELs. In the risk assessment system, exposure level is divided into four groups utilizing the cut-points of 10%, 50%, and 100% of OELs. The same schema can be adopted in the exposure assessment system and different levels of requirements can be assigned for each group. The third suggestion was regarding the regulation system. To provide the suggestions some thrust toward being implemented in the field, changes should be made in the legal system. Two different types of new exposure assessment result reporting forms were suggested. Some investigations such as an ergonomic survey are officially accepted as risk assessment under the current legal system. A few items were suggested to be included in the exposure assessment result reporting to be accepted as risk assessment. A pilot study in two small factories was performed and pointed out the strengths and weakness of our suggestions. Conclusions: Discussions and studies on the improvement of the exposure assessment system have been held for decades and no tangible changes have yet been made. We hope this result can help realize healthy lives for workers in Korea.

Suggestions to improve occupational hygiene activities based on the health problems of semiconductor workers (반도체 근로자 질병의 직무관련 논란으로 본 우리나라 산업위생 활동 개선방향)

  • Park, Donguk;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Objectives: The aim of this study is to review occupational hygiene activities, including work environment measurement as required by the industrial safety and health laws of Korea, and suggest improvements required to establish an effective exposure surveillance system. Methods: The controversial limitations of exposure surveillance examining the work-association of several types of cancers in semiconductor workers were reviewed. Results: The bulk of the exposure surveillance system was found to focus purely on work environment measurements without providing other important exposure surrogates, such as job title, operation, exposure duration, etc. The current work environment measurement system is limited in terms of the efficient assessment of the exposure status of workers due to a lack of exposure information. Conclusion: The introduction of a national standard classification of occupations and job titles into the exposure and health effect surveillance system should be discussed in order to retrospectively assess exposure characteristics.

CMOS Image Automatic Exposure System With Real-time and Robustness Style for the Journal of Korean Contents (실시간성과 강건성을 갖는 CMOS 자동노출 시스템)

  • Choi, Wonseok;Kim, HeeSu;Kim, Jaehyun;Cho, Youngki;Choi, Sungho;Lee, Yongseon
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.10
    • /
    • pp.1-13
    • /
    • 2020
  • There are many factors that influence the image quality of CMOS camera images, among which the image exposure time is an important factor. If the image exposure time is long, the entire image on the screen becomes brighter. If the exposure time is shorter, the entire image becomes darker. When photographing a still image, real time is not required because the automatic exposure system is given sufficient time to obtain an appropriate exposure time. However, if the surroundings and environment change rapidly like the black box of a driving car, the exposure time should be applied in response to real time. To this end, a robust automatic exposure system for real-time performance and ambient light environment is required. An automatic exposure system that has real-time capability and is robust against the ambient light environment is required. we designed a real-time control sysem capable of parallel operation processing through the design of an embedded system using zynq's logic and ARM core, and developed a real-time CMOS automatic exposure system that is robust to noise and converges to a desired target value within 66 ms through PID control.

Validation of a Rodent Nose-only Exposure System for Inhalation Toxicity Evaluation of Cigarette Smoke (담배 흡입독성 평가를 위한 설치류 담배연기노출시스템의 유효화)

  • Sohn, Hyung-Ok;Lee, Hyeong-Seok;Shin, Han-Jae;Park, Chul-Hoon;Yoo, Ji-Hye;Jang, Mi;Hyun, Hak-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.36 no.1
    • /
    • pp.20-25
    • /
    • 2014
  • As part of a balanced testing battery, subchronic inhalation studies on rats are performed to ensure that proposed cigarette modifications do not increase the toxicity of smoke and to demonstrate any instances where a modification may actually contribute to harm reduction. For subchronic inhalation studies with aerosols, the OECD suggests an exposure regimen of 6 hours/day (OECD Guideline 413, 1981), but alternative regimens have also been published: 1 hour/day and $2{\times}1$ hour/day. The aim of this study was to validate a rodent nose-only exposure system for the assessment of inhalation toxicity of cigarette smoke. In this study, cigarette smoke exposure system is consisted of cigarette smoke generator, smoke concentration adjusting system, and 20-port nose-only exposure system. Male SD rats were exposed for 35 days ($2{\times}1$ hour/day) to 3R4F Reference cigarette smoke and analysed major monitoring items of OECD Gudeline 413. WTPM, was measured in the test atmosphere, respiratory function (Buxco Biosystems) during exposure, postexposure urinary exposure biomarkers and alveolar neutrophiles in BAL fluid (Day 35) were evaluated. Validation demonstrated steady WTPM ($257{\pm}20ug/L$, $502{\pm}27ug/L$) and spatial uniformity (<10%). Nose port temperature ($22{\sim}26^{\circ}C$ and RH (45~75%) were acceptable over 35 days. Reductions in respiratory rate and minute volume and increase in the neutrophiles in BALF and the urinary exposure biomarkers were observed cigarette smoke dose dependently. This validation and 35-day inhalation study has shown that the rodent nose-only exposure system may be useful in the inhalation toxicity assessment of cigarette smoke.

Radiation image mapping system (방사선 영상 매핑 장치)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1884-1887
    • /
    • 1997
  • The increasing concern over radiation exposure in the nuclear industry has fostered agrressive efforts to reduce the levels of radiation exposure. One area of the effot to reduce the radiation exposure is the development of a remote radiation monitoring system. Remote radiation monitoring can serve many benificaial functions reduce exposure to radiation by plant personnel, impruve the quality of the data that is collected and recognize the radiation environment easily. Radiation mapping system gives a good information that represents radiation level distribution. The system we have developed consists of a data acquistion parts, mobile robot and remote control parts. Data acquisition parts consist of radiation detection module and vision acquistion module which collect radiation data, visiion data and distance information. In remote control parts, the acquision data are processed and displayed. We have constructed radiation mapping image by overlaying the vision and radiation data. The radiation mapping techniques for displaying the results of the survey in an easily comprehendable form will facilitate a better understanding of the radiation environment in the facility. This system can reduce workers radiation exposure and aid to help work plan, so it has significant benifits in cost and safety.

  • PDF

Development of Human Exposure and Risk Assessment System for Chemicals in Fish and Fishery Products (수산생물 중 유해물질의 인체 노출 및 위해평가 시스템 개발)

  • Lee, Jaewon;Lee, Seungwoo;Choi, Minkyu;Lee, Hunjoo
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.454-461
    • /
    • 2021
  • Background: Fish and fishery products (FFPs) unintentionally contaminated with various environmental pollutants are major exposure pathways for humans. To protect human health from the consumption of contaminated FFPs, it is essential to develop a systematic tool for evaluating exposure and risks. Objectives: To regularly, accurately, and quickly evaluate adverse health outcomes due to FFPs contamination, we developed an automated dietary exposure and risk assessment system called HERA (the Human Exposure and Risk Assessment system for chemicals in FFPs). The aim of this study was to develop an overall architecture design and demonstrate the major features of the HERA system. Methods: For the HERA system, the architecture framework consisted of multi-layer stacks from infrastructure to fish exposure and risk assessment layers. To compile different contamination levels and types of seafood consumption datasets, the data models were designed for the classification codes of FFP items, contaminants, and health-based guidance values (HBGVs). A systematic data pipeline for summarizing exposure factors was constructed through down-scaling and preprocessing the 24-hour dietary recalls raw dataset from the Korea National Health and Nutrition Examination Survey (KNAHES). Results: According to the designed data models for the classification codes, we standardized 167 seafood items and 2,741 contaminants. Subsequently, we implemented two major functional workflows: 1) preparation and 2) main process. The HERA system was developed to enable risk assessors to accumulate the concentration databases sustainably and estimate exposure levels for several populations linked to seafood consumption data in KNAHES in a user-friendly manner and in a local PC environment. Conclusions: The HERA system will support policy-makers in making risk management decisions based on a nation-wide risk assessment for FFPs.

Color Enhancement of Low Exposure Images using Histogram Specification and its Application to Color Shift Model-Based Refocusing

  • Lee, Eunsung;Kang, Wonseok;Kim, Sangjin
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.1
    • /
    • pp.8-16
    • /
    • 2012
  • An image obtained from a low light environment results in a low-exposure problem caused by non-ideal camera settings, i.e. aperture size and shutter speed. Of particular note, the multiple color-filter aperture (MCA) system inherently suffers from low-exposure problems and performance degradation in its image classification and registration processes due to its finite size of the apertures. In this context, this paper presents a novel method for the color enhancement of low-exposure images and its application to color shift model-based MCA system for image refocusing. Although various histogram equalization (HE) approaches have been proposed, they tend to distort the color information of the processed image due to the range limits of the histogram. The proposed color enhancement algorithm enhances the global brightness by analyzing the basic cause of the low-exposure phenomenon, and then compensates for the contrast degradation artifacts by using an adaptive histogram specification. We also apply the proposed algorithm to the preprocessing step of the refocusing technique in the MCA system to enhance the color image. The experimental results confirm that the proposed method can enhance the contrast of any low-exposure color image acquired by a conventional camera, and is suitable for commercial low-cost, high-quality imaging devices, such as consumer-grade camcorders, real-time 3D reconstruction systems, digital, and computational cameras.

  • PDF

Implementation of an in vitro exposure system for 28 GHz

  • Lee, Young Seung;Dzagbletey, Philip Ayiku;Chung, Jae-Young;Jeon, Sang Bong;Lee, Ae-Kyoung;Kim, Nam;Song, Seong Jong;Choi, Hyung-Do
    • ETRI Journal
    • /
    • v.42 no.6
    • /
    • pp.837-845
    • /
    • 2020
  • The objective of this study was to implement an in vitro exposure system for 28 GHz to investigate the biological effects of fifth-generation (5G) communication. A signal source of 28 GHz for 5G millimeter-wave (MMW) deployment was developed, followed by a variable attenuator for antenna input power control. A power amplifier was also customized to ensure a maximum output power of 10 W for high-power 28-GHz exposure. A 3-dB uniformity over the 80 mm × 80 mm area that corresponds to four Petri dishes of three-dimensional cell cultures can be obtained using a customized choke-ring-type antenna. An infrared camera is employed for temperature regulation during exposure by adjusting the airflow cooling rate via real-time feedback to the incubator. The reported measurement results confirm that the input power control, uniformity, and temperature regulation for 28-GHz exposure were successfully accomplished, indicating the possibility of a wide application of the implemented in vitro exposure system in the fields of various MMW dose-response studies.