• 제목/요약/키워드: Explosion prevention

검색결과 146건 처리시간 0.03초

카본블랙 제조공정의 안전성 향상에 관한 연구 (A Study on the Safety Improvement of Carbon Black Manufacturing Process)

  • 주종율;정필훈;이성은
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.153-161
    • /
    • 2023
  • Carbon black is a material in the form of fine black powder obtained by incomplete combustion or pyrolysis of hydrocarbons, and is composed of 90-99% carbon, and the rest is composed of hydrogen and oxygen. In the event of an emergency during the manufacture of carbon black, the generated tail gas should be safely discharged through an emergency line to prevent fire, explosion, and environmental pollution accidents caused by the tail gas. If the pressure continues to rise, the pressure control valve shall operate and the rupture plate shall be ruptured sequentially and the tail gas shall be discharged to the vent stack through the emergency line. As an emergency emission system, even if some untreated substances in the tail gas are released into the atmosphere, they are lighter than air, so it is safe to discharge them to a safe place through the Vent Stack. If the gas pressure is rising or worse, it is discharged from the Vent Stackine, and discharging fuel.

TRS를 이용한 실시간 무선 원격 부식감시시스템 개발(II) (The Development of Real-Time Wireless Remote Corrosion Monitoring System Using TRS(II))

  • 배정효;김대경;하태현;이현구;최상봉;정성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.618-620
    • /
    • 1999
  • The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or collapse of bridge and building and so on. So, he has been spent the money and the time for corrosion monitoring and analysis of measuring data. Therefore, KERI(Korea Electrotechnology Research Institute) has developed the real-time wireless remote corrosion monitoring system using by TRS(Trunked Radio System). The results of development for corrosion monitoring system are described briefly. Especially, the interfacing technology between the server and rectifier introduced in this paper.

  • PDF

지하철 누설전류 무선 원격 감시시스템 적용 사례 (A case study of remote wireless monitoring system for stray current due to subway system)

  • 배정효;하윤철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1817-1818
    • /
    • 2006
  • In present, most of metallic structures (gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway in Seoul and Pusan.In this case, subway system make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so on. In this paper, results of development about Wireless Remote Monitoring and Control System on Underground Pipeline in Stray Current Conditions are presented. And also field test data should be reporting.

  • PDF

A Case of the Laryngopharyngeal Burn Caused by A Microwave-Heated Egg Bite

  • Won, Seong Jun;Woo, Seung Hoon
    • 대한후두음성언어의학회지
    • /
    • 제24권2호
    • /
    • pp.122-124
    • /
    • 2013
  • Nowadays, microwave ovens are commonly used for cooking. However, the cooking certain food in microwave ovens can be hazardous. It has been reported that the heating eggs in a microwave oven can cause an explosion and injuries. The exploding eggs can cause burn injury of face, neck, eyelid, pharynx and larynx. Direct thermal damage to the larynx after swallowing microwave-heated eggs is rare. The authors report a larynx thermal injury due to microwave-heated eggs and review the cause and the prevention methods of exploding eggs.

  • PDF

정전기 방전에 의한 개소린-공기혼합기체의 최소착화에너지에 관한 연구 (The Study about The Minimum Ignition Energy for Electrostatic Discharge in The Gasoline-air Mixture)

  • 황명환;이덕출
    • 한국화재소방학회논문지
    • /
    • 제10권1호
    • /
    • pp.3-9
    • /
    • 1996
  • Electrostatic charge is generated in large scale or high speed processes dealing with materials with large resistance, or under complicated condition. Fire and explosion often occur due to electrostatic charge accumulated in flammable gases, vapor, liquids and powder. It is usually very difficult to verify the cause of accidents as well as the prevention. In this study, it is shown that the needle electrode needs the electrode gap from 1.8mm to 3.8mm, sphere electrode and plate electrodes need the electrode gap of 1.9mmfor the minimum ignition energy. The sphere electrode and the plate electrode requires 12.8mJ and 3.2mJ of minimum ignition energy respectively with the electrode gap of 1.1mm. The ignition voltage rises to very large value as the ground resistance increases.

  • PDF

산소소모열량계를 이용한 분진의 입경과 농도에 따른 분진폭발의 효율에 대한 연구 (A Study on the Efficiency of Dust Explosion According to Particle Size and Concentration of Dust Using the Cone Calorimeter)

  • 김윤석;문성웅;우인성;이동호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.116-119
    • /
    • 2011
  • 분진의 입경과 농도의 변화에 의한 분진의 폭발압력과 압력상승속도 및 그에 따른 분진폭발지수(Kst), 최소점화에너지(MIE) 및 폭발범위 등 분진폭발에 관한 많은 연구가 진행되고 있다. 폭발 메커니즘의 이해와 이를 통한 예방을 위해서는 분진폭발의 폭발효율과 열방출률(Heat Release Rate)에 관한 연구도 필요하다. 본 연구에서는 산소소모열량계를 이용하여 분진폭발 전후의 열방출률의 차이를 통하여 폭발효율과 폭발의 에너지를 정량화하고, 이를 통해 분진폭발 위험도의 정량적 평가기준을 제시하였다.

  • PDF

밀폐공간 질식재해 발생현황 고찰 및 예방에 관한 연구 (A Study on Asphyxiation Accidents occurred in the confined space, and their Prevention)

  • 권부현
    • 대한안전경영과학회지
    • /
    • 제18권3호
    • /
    • pp.47-54
    • /
    • 2016
  • A confined space means places where the risk of damage to health caused by lack of oxygen or hazardous gases in inadequate ventilation conditions and the risk of fire and explosion caused by flammable substances. Asphyxiation accidents in a confined space occured every year and also occurred more than two people at the same time. In this study, we surveyed the domestic statistical data occurred the lack of oxygen in confined space for the last 10 years(2006-2015) and, analyzed the accident by industries sector, workplace size etc. 17 fatal work accidents that occurred in confined spaces in Korea between 2013 and 2015 were investigated and analyzed using the database of the KOSHA and suggested interventions to minimize asphyxiation accidents in confined spaces. This paper is expected to be used to establish interventions planning and training as a preventive measures in workplace having confined spaces.

발전소 통합감시제어시스템의 MBC 개발 로직 실계통 적용 (Application of IMCS MBC Logic for Thermal Power Plant)

  • 신만수;유광명;변승현
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.845-851
    • /
    • 2013
  • Because the existing control system has been operating for about 20 years, it is necessary to upgrade the system for stable and efficient operation. But, there is a difficulty in maintenance by difference of manufacturer of each main control systems for boiler, turbine and generator. This developed IMCS(Integrated Monitoring and Control System) consists of more than 10,000 inputs and outputs for large scale thermal power plant. This paper consists of the development journey of IMCS MBC(mill and burner control) ; core binary protection & monitoring logic including prevention circuit of boiler explosion & implosion. In this project, the IMCS for boiler, turbine and generator was developed on basis of one communications platform. In this paper, the whole journey of development of IMCS MBC is dealt with designing software and hardware, coding application software, and validating software and hardware.

고강도 콘크리트 내화피복 특성연구 (A study on the characteristic of fire protection covering for high strength concrete)

  • 송영찬;이세현;김우재;양완희;박동철;백병훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.429-432
    • /
    • 2006
  • In this study a board was made with good fireproof materials of which test was conducted according to the fireproof test for KS F 2257 construction members, and the temperature in coated steel which has a possibility to explode with concrete surface was measured. It is not appropriate to use normal mortar or mortar covering mixed with P.P. fiber to take a measure to prevent the explosive splalling of high-strength concrete. To finalize an Al-Si (aluminosilicates) board-requires over 30mm in thickness at the minimum for the required fire resistance performance and explosion prevention.

  • PDF