• Title/Summary/Keyword: Experimental measurement

Search Result 5,390, Processing Time 0.039 seconds

A comparison between impulse oscillometry system and spirometry for spirometry for detecting airway obstruction in children (소아의 기도 폐쇄 평가에서 impulse oscillometry system과 폐활량 측정법의 비교)

  • Hur, Hae Young;Kwak, Ji Hee;Kim, Hyoung Yun;Jung, Da Wun;Shin, Yoon Ho;Han, Man Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.8
    • /
    • pp.842-847
    • /
    • 2008
  • Purpose : Measurement of forced expiratory volume in 1 second ($FEV_1$) is usually difficult to obtain in children under six years of age because it requires active cooperation. This study evaluates the sensitivity of impulse oscillometry system (IOS) parameters for detecting airway obstruction in comparison with $FEV_1$. Methods : We studied 174 children who performed the lung function and methacholine challenge tests to diagnose asthma by IOS and spirometry. Children were divided into two subgroups according to their $PC_{20}$, which is a parameter for bronchial sensitivity. We compared IOS parameters with $FEV_1$ at the baseline, post-methacholine challenge, and evaluated their correlation. Results : At the baseline, reactance at 5 Hz (X5) and resistance at 5 Hz (R5) significantly differed between the $PC_{20}$ positive ($PC_{20}{\leq}16mg/mL$) group and $PC_{20}$ negative ($PC_{20}$ >16 mg/mL) group; however, $FEV_1$, $FEV_1$ % predicted, $FEV_1_-Zs$ (Z score) did not differ. $FEV_1$ is correlated with X5 (r=0.45, P<0.01) and R5 (r=-0.69, P<0.01). $FEV_1_-Zs$ is also correlated with X5_Zs (r=-0.26, P<0.01) and R5_Zs (r=-0.31, P<0.01). After the methacholine challenge test, dose-response slopes in $FEV_1$ and X5 significantly differed between the two subgroups (P<0.05). Conclusion : IOS parameters were more discriminative than $FEV_1$ for detecting decreased baseline lung function between two subgroups and have a good correlation with $FEV_1$.

Normal antistreptolysin O titers of children by age group in the Gyeonggi-Incheon region (경인지역에서 조사한 소아의 연령별 antistreptolysin O 역가)

  • Lee, Jihun;Kim, Yoo Jung;Bin, Joong Hyun;Hwang, Ja Young;Hahn, Seong Hoon;Kim, So Young;Kim, Hyun Hee;Lee, Wonbae
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.965-969
    • /
    • 2007
  • Purpose : Measurement of antistreptolysin O (ASO) is often necessary to confirm a clinical diagnosis of recent streptococcal infection, especially in patients suspected of rheumatic fever and acute glomerulonephritis. Standard normal ranges for ASO should be established locally for each age group. We analyzed ASO to determine the upper limit of normal (ULN) ASO in children in the Gyeonggi-Incheon area. Methods : ASO in normal individual concentrations were measured quantitatively by nephelometry on sera from 753 children (Male : 381, Female : 372). ULN were determined by separating the upper 20% from the lower 80% of the group (80 percentile). Results : The mean ASO concentration calculated in a total cases was $149.9{\pm}7.2IU/mL$. The ASO concentration in neonates was $83.4{\pm}10.7IU/mL$, and lowest in the 1 year of age group, $26.7{\pm}6.6IU/mL$, and increased to $318.0{\pm}33.2IU/mL$ gradually in the 9 years of age group. Thereafter, ASO concentration decreased. The ULN for neonates was 122 IU/mL, for 0-3 years, 40 IU/mL; for 4-6 years, 113 IU/ mL; for 7-9 years, 489 IU/mL; for 10-19 years, 433 IU/mL; for 20-29 years, 122 IU/mL. Conclusion : The age-specific ULN for children in the Gyeonggi-Incheon area were determined. The distribution of ASO concentration according to age groups was different from previous reports. These results should be of clinical value to physicians to interprete the ASO results of their patients.

The significance of corpus callosal size in the estimation of neurologically abnormal infants (신경학적인 결함이 있었던 영아의 예후 판단에서 뇌량 크기의 중요성)

  • Yu, Seung Taek;Lee, Chang Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1205-1210
    • /
    • 2008
  • Purpose : The development of the corpus callosum occupies the entire period of cerebral formation. The myelination pattern on magnetic resonance imaging (MRI) is very useful to evaluate neurologic development and to predict neurologic outcome in high risk infants. The thickness of the corpus callosum is believed to depend on the myelination process. It is possible to calculate the length and thickness of the corpus callosum on MRI. Thus, we can quantitatively evaluate the development of the corpus callosum. We investigated the clinical significance of measuring various portions of the corpus callosum in neonate with neurologic disorders such as hypoxic brain damage and seizure disorder. Methods : Forty-two neonates were evaluated by brain MRI. We measured the size of the genu, body, transitional zone, splenium, and length of the corpus callosum. Each measurement was divided by the total length of the corpus callosum to obtain its corrected size. The ratio of corpus callosal length and the anteroposterior diameter of the brain was also measured. Results : There was no statistical significance in the sample size of each part of the corpus callosum. However, the corrected size or the ratio of body of the corpus callosum correlated with periventricular leukomalacia and hypoxic ischemic encephalopathy. Conclusion : The abnormal size of the corpus callosum showed a good correlation with periventricular leukomalacia and hypoxic ischemic encephalopathy in neonates. We can predict clinical neurological problems by estimation of the corpus callosum in the neonatal period.

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.

Study on the diagnostic utility of serum levels of insulin-like growth Factor-I and insulin-like growth factor binding protein-3 in growth hormone deficiency (성장호르몬 결핍증 진단에 있어서 혈중 insulin-like growth factor-I 및 insulin-like growth factor binding protein-3 농도의 진단적 유용성에 대한 연구)

  • Ji, Geun Ha;Lee, Jeong Nyeo;Chung, Woo Yeong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.12
    • /
    • pp.1329-1335
    • /
    • 2008
  • Purpose : This study aimed to determine the best cutoff line for insulin-like growth factor (IGF)-I and insulin-like growth factor binding protein (IGFBP)-3 to discriminate between growth hormone deficiency (GHD) patients and the control group. Methods : Two hundred thirty subjects with normal controls (129 boys and 101 girls, aged 7-15 years), 14 patients with complete GHD (12 boys and 2 girls), and 17 patients with partial GHD (9 boys and 8 girls) were studied. IGF-I serum concentrations were measured by radioimmunoassay (RI), and IGFBP-3 concentrations were measured by immunoradiometric assay (IRMA). Results : The receiver operating characteristic (ROC) plot analysis showed that the best IGF-I and IGFBP-3 cutoff line was at -1 standard deviation (SD). By comparing IGF-I serum levels of GHD children within 1 SD of normal control, we determined the sensitivity (S) (87.5-100%) and specificity (Sp) (80-84.6%) according to the age group. For IGFBP-3, we determined the following values: S (58.7-85.7%) and Sp (79.2-85.5%). Eleven of 14 patients with complete GHD (78.5%) and 16 of 17 patients with partial GHD (94.1%) had IGF-I concentrations equal to or below -1 SD of the control group mean. Ten of 12 complete GHD children (83.3%) and 13 of 17 partial GHD children (76.5%) had IGFBP-3 concentrations equal or below -1 SD of the control group mean. Conclusion : We conclude that the measurement of IGF-I and IGFBP-3 concentrations might provide essential supplementary data in the diagnostic evaluation of patients with GHD. Our results support the need to use cutoff lines based on below -1 SD of the control.

Comparative Analysis of Bone Mineral Contents with Dual-Energy Quantitative Computed Tomography (이중에너지광자선의 전산화단층촬영술을 이용한 정량적 골무기물함량의 비교분석)

  • Choi, Tae-Jin;Yoon, Seon-Min;Kim, Ok-Bae;Lee, Sung-Moon;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 1997
  • Purpose : The Dual-Energy Quantitative Computed Tomography(DEQCT) was compared with bone equivalent $K_2HPO_4$ standard solution and ash weight of animal cadaveric trabecular bone in the measurement of bone mineral contents(BMC). Method and Materials : The attenuation coefficient of tissues highly depends on the radiation energy density and effective atomic number of composition, The bone mineral content of DEQCT in this experiments was determined from empirical constants and mass attenuation coefficients of bone,fat and soft tissue equivalent solution in two photon spectra. In this experiments, the BMC of DEQCT with 80 and $120kV_p$ X rays was compared to ash weight of animal trabecular bone. Results : We obtained the mass attenuation coefficient of 0.2409 0.5608 and 0.2206 in $80kV_p$, and 0.2046, 0.3273 and $0.1971cm^2/g$ in $120kV_p$ X-ray spectra for water bone and fat equivalent materials, respectively. The BMC with DEQCT was acomplished with empirical constants $K_1=0.3232,\;K_2$=0.2450 and mass attenuation coefficients has very closed to ash weight of animal trabecular bone The BMC of empirical DEQCT and that of manufacturing DEQCT were correlated with ash weight as a correlation r= 0.998 and r= 0.996, respectively. Conclusion : The BMC of empirical DEQCT using the experimental mass attenuation coefficients and that of manufacture have showed very close to ash weight of animal trabecular bone.

  • PDF

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Aggregate Effects on γ-ray Shielding Characteristic and Compressive Strength of Concrete (콘크리트의 감마선 차폐특성 및 압축강도에 대한 골재의 영향)

  • Oh, Jeong-Hwan;Mun, Young-Bum;Lee, Jae-Hyung;Choi, Hyun-Kook;Choi, Sooseok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.357-365
    • /
    • 2016
  • We observed the ${\gamma}-ray$ shielding characteristics and compressive strength of five types of concrete using general aggregates and high-weight aggregates. The aggregates were classified into fine aggregate and coarse aggregate according to the average size. The experimental results obtained an attenuation coefficient of $0.371cm^{-1}$ from a concrete with the oxidizing slag sand (OSS) and oxidizing slag gravel (OSG) for a ${\gamma}-ray$ of $^{137}Cs$, which is improved by 2% compared with a concrete with typical aggregates of sand and gravel. In the unit weight measurement, a concrete prepared by iron ore sand (IOS) and OSG had the highest value of $3,175kg{\cdot}m^{-3}$. Although the unit weight of the concrete with OSS and OSG was $3,052kg{\cdot}m^{-3}$, which was lower than the maximum unit weight condition by $123kg{\cdot}m^{-3}$, its attenuation coefficient was improved by $0.012cm^{-1}$. The results of chemical analysis of aggregates revealed that the magnesium content in oxidizing slag was lower than that in iron ore, while the calcium content was higher. The concrete with oxidizing slag aggregates demonstrated enhanced ${\gamma}-ray$ shielding performance due to a relatively high calcium content compared with the concrete with OSS and OSG in spite of a low unit weight. All sample concretes mixed with high-weight aggregates had higher compressive strength than the concrete with typical sand and gravel. When OSS and IOS were used, the highest compressive strength was 50.2 MPa, which was an improvement by 45% over general concrete, which was achieved after four weeks of curing.

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

Establishment of Choline Analysis in Infant Formulas and Follow-up Formulas by Ion Chromatograph (이온크로마토그래프를 이용한 조제유류 및 영아용·성장기용 조제식 중 콜린 함량 분석법 연구)

  • Hwang, Kyung Mi;Ham, Hyeon Suk;Lee, Hwa Jung;Kang, Yoon Jung;Yoon, Hae Seong;Hong, Jin Hwan;Lee, Hyoun Young;Kim, Cheon Hoe;Oh, Keum Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.411-417
    • /
    • 2017
  • This study was conducted to establish the analysis method for the contents of choline in infant formulas and follow-up formulas by ion chromatograph (IC). To optimize the method, we compared several conditions for extraction, purification and instrumental measurement using spiked samples and certified reference material (CRM; NIST SRM 1849a) as test materials. IC method for choline was established using Ion Pac CG column and 18 mM $H_2SO_4$ mobile phase. The parameters of validation were specificity, linearity, LOD, LOQ, recovery, accuracy, precision and repeatability. The specificity was confirmed by the retention time and the linearity, $R_2$ was over 0.999 in range of 0.5~10 mg/L. The detection limit and quantification limit were 0.14, 0.43 mg/L. The accuracy and precision of this method using CRM were 95%, 2.1% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested products were acceptable contents of choline compared with component specification for nutrition labeling. The standard operating procedures were prepared for choline to provide experimental information and to strengthen the management of nutrient in infant formula and follow-up formula.