• 제목/요약/키워드: Exciting Frequency

검색결과 247건 처리시간 0.032초

주파수 조절이 가능한 자려식 공진형 인버터의 고속 게이트 구동회로 (Frequency controllable fast switching gate driver for self-resonant inverters)

  • 류태하;채균;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2783-2785
    • /
    • 1999
  • A fast switching gate driver suitable for high performance self resonant electronic ballasts is presented. The proposed gate driver has negligible switching loss and driving loss owing to pnpn structure and zero voltage switching( ZVS ); moreover, the gate driver has frequency control capability. Therefore, a self resonant inverter using proposed gate driver can operate as external exciting resonant inverters. The experiments confirm that the proposed gate driver perform the desired operations over full power control range for 40W fluorescent lamp electronic ballast.

  • PDF

선형 압축기의 동적 거동 예측 Simulation Tool 개발 (Development of Simulation Tool for Dynamic Behavior of a Linear Compressor)

  • 전수홍;정의봉;이효재;김당주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권4호
    • /
    • pp.476-483
    • /
    • 2009
  • A linear compressor used in a refrigerator has higher energy efficiency than a reciprocating compressor, but its vibration level is still severe than others. The vibration level of linear compressor at the frequency of 60Hz is dominant since it is the exciting frequency of a motor. In this paper, a simulation tool to predict the shell vibration of the linear compressor was developed. The shell and body parts in a compressor were assumed to be 3-dimensional rigid body having both translational and rotational motion, while the reciprocating piston part has only 1-dimensional translational motion. The flexible loop-pipe was modeled by in-house code of finite element method. To verify the developed tool, five cases of different loop-pipe shapes were examined experimentally. The results by the developed tool showed good agreements with those by experiments.

Exciting High Frequency Oscillations in a Coaxial Transmission Line with a Magnetized Ferrite

  • Ahn, J.-W.;Karelin, S.Y.;Kwon, H.-O.;Magda, I.I.;Sinitsin, V.G.
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.460-465
    • /
    • 2015
  • The paper presents methodologies and results concerning one- and two-dimensional numerical modeling of radio frequency oscillations in a coaxial transmission line fed with a short pulse of electric current. The line is partially filled with a ferrite material, magnetized longitudinally close to saturation. The 2D model has permitted analyzing, for the first time in the art, the spatial structure and dynamics of the wave field within the radially non-uniform cross-section planes of the non-linear and dispersive guiding structure. This opens ways for optimizing size parameters of the line and the extent to which it is filled with the ferromagnetic material, thus increasing the line's electric strength and intensity of the r.f. oscillations.

에어컨 실내기 팬 모터용 방진고무의 동특성 측정에 관한 연구 (A Study on the Measurement of Dynamic Properties of the Rubber Mount in the Impeller Fan Motor of the Air-conditioner)

  • 최현;김준우;강태호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.185-190
    • /
    • 2001
  • The structure borne noise of the air-conditioner, which degrades the noise quality, is hardly reduced by the general noise treatments. It can be effectively reduced by eliminating the structural vibration which the noise originates from. The rubber vibration isolator prevents the dynamic force induced by the fan driving motor from exciting the chassis structure, which finally reduces the structure borne noise. The dynamic properties of the vibration isolation system such as the natural frequency of the vibration isolation and loss factor of the rubber isolator, need to be experimentally evaluated. In this paper, these dynamic properties were obtained by the resonant method using the impact hammer for 3 types of the isolator specimens. It is known that the isolation natural frequency of the axial direction of the rubber isolator is two times higher than that of the radial direction, and is proportional to the hardness of the rubber specimen.

  • PDF

전단벽식 건축구조물 수직진동의 수평방향 전달특성에 관한 실험연구 (An Experimental Study on the Vertical Vibration Transfer in Horizontal Way according to Shear Wall Building Structures due to Exciting Vibration Forces)

  • 전호민
    • 한국소음진동공학회논문집
    • /
    • 제16권3호
    • /
    • pp.270-282
    • /
    • 2006
  • In general, the vertical vibration problems for strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions to near-rooms on the shear wall building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on two building structure. The results from the experiments are analyzed and compared with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs, and are effected the shear wall on the Path of the vibration transfer.

축소 건물모델의 모달 파라미터 추정에 관한 연구 (A Study on the Modal Parameters of the scaled building structure)

  • 박해동;박진일;최현;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.571-575
    • /
    • 2000
  • The physical properties of the spatial model, mass, stiffness and damping matrix, can be defined by a specific natural frequency, damping ratio and mode shape. These modal parameters can be determined from a set of frequency response function(FRF) measured by exciting the structure and measuring the responses at various points around the structure. In this paper, The Transfer Matrix is obtained by experimental modal analysis for the 3-story scaled building model which TMD is installed on top and the physical properties of the spatial model is determined using the residue matrix and the location of poles from FRF measurement using polynomial curve fitting methods.

  • PDF

유전체의 밀리미터파대 유전특성 평가방법에 관한 연구 II (A Study of the Estimation Method for the Dielectric Properties of Dielectrics in Millimeter Wave Range - Part II)

  • 이홍열;전동석;김동영;고경석;이상석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.135-138
    • /
    • 2003
  • The circular cavity resonator which can measure the dielectric properties of dielectrics in the V-band($50GHz{\sim}75GHz$) frequency range was designed and fabricated. Exciting and detecting of the resonator is peformed by WR15 rectangular waveguides using Bethe's small hole coupling. The GaAs plate sample was used for the verification of the performance of the fabricated circular cavity resonator. In the measurement of GaAs single crystal using that resonator, the resonant frequency of the dominant $TE_{011}$ mode, the permittivity and $Q{\times}f_0$ were measured as 53.29GHz, 12.87 and 138,000, respectively.

  • PDF

벽식점성감쇠기의 감쇠 성능에 관한 기초적인 연구 (Experimental Study on Energy Dissipation Capacities of the Viscous Damping Wall)

  • 이장석;김남식;조강표
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.246-251
    • /
    • 2003
  • This paper presents an experimental study on the energy dissipation characteristics of viscous damping wall (VDW). VDW is consisted of a plate floating in a thin case made of steel plated filled with highly viscous silicone oil. Because VDW demonstrates both viscous damping and stiffness characteristics, the viscous resisting force can be expressed as the sum of velocity dependant viscous damping force and displacement dependant restoring force. The viscous resisting force and energy absorbing capacity can be easily adjusted by changing three factors, i.e. viscosity of the fluid, gap distance and area of the wall plates. VDW was tested using a series of harmonic (sinusoidal) displacement history having different frequency and amplitude and the force-displacement relationship was recorded. The relationship between dissipated energy with three factors and the influence of exciting frequency on resisting force were Investigated

  • PDF

차량용 HDD 의 수동형 진동저감 시스템 설계 (Design of Passive Vibration Attenuation System for a Vehicle HDD)

  • 김진남;김영추;권원태
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.117-122
    • /
    • 2010
  • The shock performance of hard disk drives has been a serious issue for Car PC. Since the vibration and disturbances from a car gives an adverse effect on a HDD of Car PC, it is necessary to protect a HDD from them. In this study, passive vibration attenuation system for a vehicle HDD was developed. Acceleration from the ground through the tire and suspension system was measured to figure out the frequency translated to Car PC. Critical frequency to Car PC was determined by exciting it with a shaker and measuring a data transmitting speed from HDD. A newly designed vibration attenuation system was fabricated to protect HDD from the acceleration. It was shown that the developed system had an excellent vibration attenuation ability.

구조 공진회피에 의한 변압기 소음저감 (A Study of the Low Noise Transformer by Avoiding the Structural Resonance)

  • 최원호;김진;석호일
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.520-526
    • /
    • 2005
  • Demands for the noise reduction of a transformer has been becoming an common issue because it has been used mainly at the residence area such as an apartment complex. This paper shows 2 trouble shooting examples that high noise sources were found out structural resonance of a transformer by 120Hz exciting frequency caused from magnetostrictive vibration of core. This paper presents that vibration data are very important to find noise source and how to avoid natural frequency of core and tank wall