• Title/Summary/Keyword: Evaluation of Daylight

Search Result 77, Processing Time 0.024 seconds

A Study on the Improvement Method of Indoor Light Environment Items in Environmental Certification for Educational Facilities - Focusing on G-SEED, LEED, BREEAM, CASBEE - (교육시설 친환경 인증에서 실내 빛환경 항목 개선방안에 관한 연구 - G-SEED, LEED, BREEAM, CASBEE를 중심으로 -)

  • Lee, Se-Won;Lee, Kyung Sun;Kim, Sooran
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.5
    • /
    • pp.61-69
    • /
    • 2018
  • The goal of this study is to compare the evaluation results of indoor daylight environment for each certification and propose improvement points. As the importance of indoor daylight environment has increased, foreign countries have been aware of this and have changed the light environmental certification items. On the other hand, Korea environmental certification systems have not been able to follow the current situation. In order to improve this, this study intended to find evaluation criteria for each category by comparing and analyzing indoor daylight environment certification items in Korea's G-SEED, LEED in the United States, BREEAM in the UK, and CASBEE in Japan. After that, this study simulated 3D models of three spaces about classroom, reading room and club room of Yanghyun elementary School which is scheduled to be constructed for the evaluation of indoor daylight environment, and the results were analyzed to suggest for improvement.

Daylighting Performance Nomographs for Toplit Atrium (아트리움의 자연채광 성능 예측용 노모그래프)

  • Kim, Jeong-Tai;Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.3 no.2
    • /
    • pp.45-50
    • /
    • 2003
  • Today, there are increasing evidences that daylight is essential for health, well-being and productivity. One of the strong contributions, which atria can make to advantages in building, is in allowing the use of daylight. This research is to develop nomographs and to evaluate the daylight performances of toplit atria with louvers. For this purpose, the evaluation models of toplit atria with well indexes of 0.5, 1.0 or 2.0 have been selected through the field surveys of atrium buildings in Seoul area. Also, weather data for solar irradiance and luminous efficacy were gathered from the recently conducted previous researches. The computer simulations were performed under clear sky conditions, using the ADELINE program, and various daylight performances were analyzed by the daylight illumination ratio. Analyzing the simulation results, solar altitude, solar azimuth, and louver angle and louver reflectance were found to be important factors affecting the daylight performance of toplit atria. Using these variables, regression equations have been formulated, and the nomographs, which may predict the daylight performances of toplit atria with louvers, were developed. The developed nomographs were validated through comparing the results of nomograph predictions to the results of scale-model experiments.

Application of the Daylight Factor Formula with the Modified Split Flux (Modified Split Flux를 이용한 주광률 계산식 적용에 관한 연구)

  • Yun, Su-In;Yun, Gyeong;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.39-47
    • /
    • 2014
  • Daylighting has a great effect on people inside the room. It is also closely related to the lighting energy consumption. Daylight factor(DF) is a very important index for evaluation of the daylighting in overcast sky. The objective of this study is to verify the suitability of the Tregenza's Modified Split Flux formula for the calculation of the daylight factor. We compared the daylight factors calculated by two methods; one by a measurement with 1/5 scale model and the other by the Daysim program. We used variables for verification as window wall ratios(WWR) and angles of the sky visible. As a result, daylight factor calculated by Modified Split Flux is similar to the measurement when more daylight enters the inside. And error is significantly increased when the angle of the sky visible is $50^{\circ}$.

Design of Daylighting Aperture Using Daylight Factor Method and its Evaluation by Distribution of Sky Component (Daylight Factor Method를 이용한 채광창의 설계)

  • 지철근;권영혜
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.1
    • /
    • pp.58-63
    • /
    • 1989
  • 이등분한 실의 주광율(Daylight Factor)의 비를 규제도의 지수로서 Lumen Method와 같이 정하고, 이를 만족하는 실의 깊이를 검토한 후, 설계 평균 주광율을 만족하는 창의 면적을 구하였다. 본 논문에서 제안한 창의 면적 자체가 다른 벽면의 면적 변화에 영향을 주고 있음을 고려하지 않은 종래의 방법을 개선하였다. 이후 주광율 요소 중 가장 지배적인 양인 운천공으로부터 입사하는 성분(SCo: Sky Component from overcast Sky)의 분포를 창의 위치와 형태를 변화시켜 조사, 평가하였다.

  • PDF

Design of Daylighting Aperture Using Daylight Factor Method and its Evaluation by Distribution of Sky Component (Daylight Factor Method를 이용한 채광창의 설계와 주광율의 직접조도분에 의한 채광창의 평가)

  • Chee, Chol-Kon;Kwon, Young-Hye
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.210-213
    • /
    • 1988
  • A new and accurate expression to derive a window area is presented with a sequence for daylighting design using Daylight Factor Method process not in its classical point--by-point method but in lumen method as in artificial lighting design process to consider daylight in the early stage of a building design process. Accepting CIE Overcast Sky as the worst state with the lowest sky luminance, a user of a room can have more available daylight in his or her room. In the design process uniformity is checked to ensure reasonably even daylighting by comparing the depth of the room with the computed limiting depth. After these steps the shape and position of window is altered, of which the Sky Component of Daylight Factor under an Overcast Sky, SCo, is investigated and computed in Composite Simpson Multiple Integral so that a building designer or an analyst can choose the best shape and location that satisfies his/her taste and purpose of the room.

  • PDF

A study on lighting Diffusion system of Daylight Duct System (광덕트방식 자연채광 시스템의 산광부에 대한 연구)

  • Song, Kyu-Ryol;Park, Gyeong-Woo;Ryu, Han-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.99-104
    • /
    • 2011
  • Daylighting system is an alternative to the energy crisis and environment change. And it is possible improvement system of Architectural Space Environment. Accordingly, it is very useful system. Because Daylight Duct System of Daylighting System gives high performance for its price, distribution rate is very high. But Daylighting Duct System is hard to accurate control. Accordingly, it is difficult to maintain continuously Daylight Environment in Interior Spaces. Lighting Diffusion System has been developed that it is Applying the principle of Reflector and prism diffuser for maximize the efficiency of lighting of Daylight Duct Systems through this study. And then compare lighting performance of Existing System and new Lighting Diffusion System through producing a mock-up. Thus, this study was carried out for the purpose of verification for excellence. It is that installed Each Daylighting Duct System for performance evaluation in a laboratory of width 4m, length 10m, height 2.5m. And illuminance was measured at noon on winter solstice(December 22) under clean sky. The actual measurement result was in the following. Newly developed lighting Diffusion system was measured maximum illuminance 399, minimum illuminance 221, average illuminance 141. Synthetically, daylight factor, uniformity factor and illuminance distribution were improved more than existing system. As a result, it was confirmed that was improved lighting Environment in Interior Spaces.

  • PDF

Application of Simplified Daylight Prediction Method for Daylighting Performance Evaluation on Overcast Sky (실내 주광조도 간이 예측식을 활용한 담천공 시의 자연 채광 성능 평가)

  • Yoon, Kap-Chun;Yun, Su-In;Kim, Seong-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.1-9
    • /
    • 2014
  • Daylight is very useful to control the indoor environment, and can save energy in buildings. So it is necessary to evaluate the daylighting performance of buildings. We proposed a simplified equation that can be used in the early stages of design. And we verified the equation by using the measured illuminance data from the 1/5 scale model. We compared the calculated indoor illuminances and measured illuminance including Daylight Factors of scale model in order to verify the applicability of the simplified equation, and proved the analyzed values are acceptable. When we have a target value of the Daylight Factor, we just have to determine the window area, transmittance of the glazing system, and indoor surface reflectance, then can achieve it with this simplified equation.

Sky Ratio Diagram for the Evaluation of Daylight Environment at the Children's Playground (어린이놀이터의 빛환경 평가를 위한 천공률산정도 작성)

  • Kim, Won Woo;Kim, Eun Shim
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.39-44
    • /
    • 2012
  • The children's playgrounds have been installed almost from the beginning when the first apartment complex was built. The brightness of a playground has not been considered in the architectural plan. The site of the playground has been chosen based on availability without making a detailed review on its daylight environment. The purpose of this study is to provide the Sky Ratio Diagram for the evaluation of daylight environment at the children's playground in apartment complexes. the Sky Ratio Diagram has 100 points, each point has a value of equal to the sky ratio 1%. Through case studies, the Sky Ratio Diagram was verified whether it could be practically applied to the actual playgrounds. This research is meaningful in that it suggests a way to quantitatively evaluate the brightness of a playground. The Sky Ratio Diagram suggested in this study can be practically used when choosing a site for a playground within an apartment complex.

A Study on the Autumn LED Emotional Lighting Color through the comparative analysis of the Daylighting and LED Lighting Color (자연광과 LED조명색채 비교분석을 통한 가을빛 LED감성조명 색채 연구)

  • Yang, Jung-Soon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.1-13
    • /
    • 2011
  • The purpose of this study is the realization of LED light environment closely resembling the Autumn daylight which people feel comfortable with. This research was conducted through an optical experiment and Emotional evaluation through human's eyes. Human beings are affected by the color of light, quality and light intensity. Unlike the past when human beings have worked mainly in daylight, the urbanites today spend most of the time in indoor spaces. Therefore, the artificial light is needed to strive toward a spectrum of daylight. This study is purposed to provide the pleasant light environment for human beings and build its database. This study course is expected to contribute to the new design methodology of the related fields under the development of the LED emotional lighting color.

An Evaluation of Daylight Performance in the Reading Room of a Library according to Different Azimuths and Louver Systems (도서관 열람공간의 방위 및 루버시스템에 따른 주광성능 평가)

  • Park, Joo-Hyun;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.45-51
    • /
    • 2006
  • Recently, various kinds of daylight system are recognized as an important and useful strategy in energy-efficient building designs. However, a large amount of direct sunlight can make many problems. Therefore, it is necessary to control daylighting through louver systems for high quality visual environment. The purpose of this study is to analyze daylighting performance in the reading room of a library according to different azimuths and louver systems. The results evaluated daylight performance based on the RADIANCE lighting software.