• 제목/요약/키워드: Evaluation contrast effect

검색결과 159건 처리시간 0.021초

친환경건축물인증제도의 평가지표 분석에 관한 연구 - 서울시 학교시설의 사후평가를 중심으로 - (A Study on Evaluation Indicator Analysis of the Green Building Certification - Focused on Post Evaluation of the Education Facilities case in Seoul -)

  • 문선기;신은경;김세용
    • 교육시설 논문지
    • /
    • 제20권3호
    • /
    • pp.41-52
    • /
    • 2013
  • In the current condition of seeking eco-friendly development, Green Building Certification Criteria can reduce environment burden that is able to be arose in life cycles of buildings. Moreover, it is a great help to induce to constructing pleasant environment. The ripple effect that also improves saving of energy and resources of the whole country, and green-house gases reduction effect and environment friendliness of other buildings can be expected by promoting eco-friendly education facilities which accounts for a great part of public buildings in comparison with other buildings. In this study, analysis of old and new indicators' contrast and contents in Green Building Certification, and post evaluation of education facilities and interviews on authorities were proceeded for improving evaluation indicator of each item in Green Building Certification Criteria. As a result, it analyzed problems in terms of institution and operations management, and drew implications accordingly. In addition, it has a significance in that it proposes improvements of substantively applicable indicators with high applicability.

보청기에서 음성 대비 강조에 의해 발생할 수 있는 마스킹 현상 (Acoustic Masking Effect That Can Be Occurred by Speech Contrast Enhancement in Hearing Aids)

  • 전유용;양동권;방동혁;길세기;이상민
    • 재활복지공학회논문지
    • /
    • 제1권1호
    • /
    • pp.21-28
    • /
    • 2007
  • 대부분의 보청기에서는 난청인의 청력 손실을 보상하기 위해 음성 증폭 알고리즘과 잡음 및 피드백을 제거하기 위한 알고리즘 등을 사용하고 있고, 음성의 인지율을 높이기 위해서 음성의 대비를 강조하는 알고리즘을 사용한다. 음성 대비 강조 알고리즘 사용 시 과도한 대비증폭에 의해서 포먼트(formant) 사이에서 마스킹 현상이 발생할 수 있다. 마스킹 현상을 확인하기 위해서 6가지의 주관적인 평가와 1가지의 객관적인 평가를 수행하였다. 주관적인 평가로는 순음 검사, 어음 청취 역치 검사, 낱말 분별력 검사, 순음 마스킹 검사, 포먼트 순음 마스킹 검사, 어음 마스킹 검사로 이루어져있고 객관적인 평가를 위해서 LLR(log likelihood ratio)을 도입하였다. 정상 청각 피험자와 난청 피험자의 결과로 미루어 볼 때, 난청 피험자가 마스킹이 잘 일어난다는 것을 볼 수 있었고, 어음을 이용한 마스킹 검사에서는 마스킹에 의해서 난청 피험자에서 어음에 대한 인지율이 떨어지는 결과를 볼 수 있다. 이러한 현상은 포먼트 향상에 의한 왜곡 때문이 아닌 마스킹 때문이다. 그러므로 마스킹 효과의 특성을 조사하여, 보청기 적합 시, 이러한 마스킹 특성을 고려하는 것이 필요하다.

  • PDF

동시 PET-MRI를 위한 N-(p-maleimidophenyl) isocyanate linker-매개 합성을 이용한 복합 조영제의 평가 (Evaluation of Combined Contrast Agent using N-(p-maleimidophenyl) Isocyanate Linker-mediated Synthesis for Simultaneous PET-MRI)

  • 이길재;이훈재;이태수
    • 한국방사선학회논문지
    • /
    • 제16권2호
    • /
    • pp.103-113
    • /
    • 2022
  • 이 논문에서는 결합된 PET(fluorodeoxyglucose, 18F-FDG)와 MRI(magnetic nanoparticles, MNP) 조영제를 동시 PET-MRI 스캔에 사용하기 위한 가교제로 N-(p-maleimidophenyl) isocyanate를 사용하여 합성하는 방안을 제안하였다. 실험은 신경교종 줄기 세포 마우스 모델에서 결합 조영제(18F-FDG로 표지된 MNP)를 주입하기 전후에 PET-MRI 이미지를 획득하고 평가하였다. 획득한 각 영상에 대해 관심영역(ROI)을 설정한 후, 분할하여 병변의 면적을 계산하였을 때 PET 영상이 MRI 영상보다 더 크고 정확했다. 특히 동시 PET-MRI 영상은 주변 연조직과 함께 정확한 병변을 묘사하였다. 평균 및 표준편차 값은 조영제 주입 여부에 관계없이 PET 영상 또는 PET-MRI 동시 영상보다 MRI 단독 영상에서 더 높게 나타났다. 또한 동시 PET-MRI 영상값이 PET 영상보다 평균 및 표준편차 값이 높게 나타났다. 18F-FDG 라벨링된 MNP 조영제와 동시 PET-MRI 영상을 표적 영상으로 사용하고 18F- FDG 조영제만을 원본 이미지로 사용했을 때의 피크 신호 대 잡음비(PSNR) 값은 모든 실험에서 유의미 하게 나타났다. 결론적으로 동시 PET-MRI 영상에서 결합된 18F-FDG 표지 MNP 조영제가 유용함을 확인하였다. 다양한 핵종을 사용할 수 있는 SPECT-MRI 영상 연구를 통해 진단과 치료를 동시에 할 수 있는 제제를 개발하기 위해서는 향후 연구가 필요할 것이다.

심혈관 조영술 시행 환자의 조영제 사용 시 사구체여과율 변화에 영향을 미치는 인자들 평가 (Evaluation of Factors Affecting Glomerular Filtration Rate by Contrast Media in Patients with Coronary Angiography)

  • 김은영;이옥상;임성실
    • 한국임상약학회지
    • /
    • 제22권2호
    • /
    • pp.103-112
    • /
    • 2012
  • Performance of coronary angiography for exact diagnosis and treatments of cardiovascular disease have been increased recently and it also brings increase of the contrast-induced nephropathy (CIN) referred from increasing use of radiological contrast agents. The variation of estimated glomerular filtration rate (eGFR) is an indicator of CIN, which is known to increase when renal function is decreased. Therefore, this study was to evaluate the affecting factors including concomitant drug on variation of eGFR of patients who underwent coronary angiography according to the conditions of renal function. Medical records of 66 patients were evaluated retrospectively and the patients underwent coronary angiography or angioplasty with nonionic and isotonic contrast media (iodixanol) at Chungnam national university hospital from 1 Jan 2008 to 30 Jul 2010. Patients group was divided into 2 groups; the patients in stages 3-4 chronic kidney disease (CKD) and the patients in stage 2 CKD. Each group was researched about the effect of concomitant drug and clinical characteristics on eGFR variation. The change of eGFR was compared among baseline and 2 or 3 day after coronary angiography. In results, the eGFR variation in group over age 75 was significantly decreased after radiological contrast agents exposure (p $$\leq_-$$ 0.05). The eGFR variation in anemia was significantly decreased after radiological contrast agents exposure in stage 2 CKD (p > 0.05). The eGFR variation in group under $HbA_{1c}$ 6.5% was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). The eGFR variation by taking statins, angiotensin converting enzyme inhibitors, calcium channel blockers and nitroglycerin was increased after radiological contrast agents exposure in stage 2 CKD (p $$\leq_-$$ 0.05). The eGFR variation by using of diuretics was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). The eGFR variation by taking statins, nitroglylcerin was increased after radiological contrast agents exposure in stages 3-4 CKD(p > 0.05). The eGFR variation in group over contrast dosage 150 ml was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). Therefore, when undergoing coronary angiography, contrast dosage should be minimized less than 150 ml, and diuretics should be restricted as possible in stages 3-4 CKD. Patients over age 75 require special attention to prevent CIN, and if patients undergo coronary angiography in stages 3-4 CKD, $HbA_{1c}$ is also requried to maintain below 6.5% to prevent CIN.

간동맥 색전술 환자의 복부단층촬영 후 PC 환경에서 MIP재구성영상을 이용한 간문맥평가에 관한 고찰 (A Study on Evaluation of Portal Vein by Utilizing MIP Reconstruction in the PC Environment after Abdomen CT of Hepatic Artery Embolization Patients)

  • 김영근;장영일;허영남
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.13-17
    • /
    • 2001
  • When most patients are diagnosed with the quiet progressed hepatoma which often would make the operation impossible, the Interventional Radiology hepatic artery embolization is an extremely useful method for such patients. An existence of the malfunction is evaluated by gaining a portal vein image as a delayed phase image after injecting a contrast media into the superior mesenteric artery. However, it is difficult to make a definite judgement due to the extended exposure time with the peristalsis and the intestine gas obstructing the sharpness of the image when the Patient exposure time increases and due to the increased usage of contrast media and its side effect. The portal vein can be evaluated by obtaining the MIP image after reconstructing a 3-dimensional personal computer setting using the 2-dimensional from an enhancement abdomen CT image that is almost a requisite in operation to a hepatoma patient. Such method nay prevent a decrease in the quality of image based upon the time delay and intestine gas; also, because the patient exposure dose and contrast media usage may be reduced, it is a new, valuable way to decide the operational matter of hepatic artery embolization on a pre-angiography.

  • PDF

Application of a newly developed software program for image quality assessment in cone-beam computed tomography

  • de Oliveira, Marcus Vinicius Linhares;Santos, Antonio Carvalho;Paulo, Graciano;Campos, Paulo Sergio Flores;Santos, Joana
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.75-86
    • /
    • 2017
  • Purpose: The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. Materials and Methods: A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. Results: The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. Conclusion: This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.

제품설계와 평가를 위한 시각영역의 생성 (Generation of a practical visual field for the design and evaluation)

  • 기도형
    • 대한인간공학회지
    • /
    • 제14권1호
    • /
    • pp.59-67
    • /
    • 1995
  • Depending upon the eye and head movement, the visual field is often classified into three categories ; stationary field, eye field and head and eye field. To investigate the effect of background condition on the size of the visual field, an experiment was conducted, in which the subject was instructed to search a target with distinct orientations. In each trial, a single target was presented on the perimeter modified to cover the range of 330 .deg. around the fixation point, with the visual angle subtended 1.4 .deg. vertically and horizontally. Nontarget density, meridian, size contrast and subject showed a significant effect on the visual field at .alpha. =0.01, where density was inversely proportional to the size of the visual field, and size contrast linearly proportional to the size of the visual field. The size of the visual field on horizontal axis was larger than that on vertical axis, and that on right and upper meridian was also larger than on left and lower meridian. The shape was found to be horizontally oriented oval and statistically asymmetric with respect to horizontal and vertical axes. In addition, the regression equations to predict the visual field on the given background condition were suggested. These results were expected to be used as a design guideline when arranging displays and controls on panels such as automobile display panels, cockpits, etc.

  • PDF

수직형 LED 조명의 색상 및 점멸에 따른 눈부심 주관평가 (Subjective Evaluation of Glare for Blinking and Colors of Vertical LED Lighting)

  • 정현지;김인태;최안섭
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.22-30
    • /
    • 2015
  • Currently, in South Korea, 'Light Pollution Prevention Act by Artificial Lighting' has been enforced. For advertising lighting, it is limited based on only the light-emitting luminance. Luminance is a concept related to the glare. Not only the luminance of the light source, but also glare is affected depending on some situations like blinking, luminance contrast, background illuminance. This study conducted glare subjective evaluation with brightness, color, and blinking by looking at the LED lighting box. The results showed that the glare indexes were higher about 2 times in a decrease of background illuminance from 100lx to 0lx. The glare index of R, G, B light was higher than that of white light. The average glare index of the blue light was higher about 8 times compared to 2,700K. And the blink rate had little effect on the glare, but it affected the irritation. Therefore, the glare effect of light color and blinking needs to be considered for the standard of luminous environment.

자극 습관화가 자동차 경적음의 심리음향 특성에 따른 심리생리적 予분에 미치는 영향 (The influence habituation on psychophysiological differentation of automobile horns with different psychoacoustic characteristics)

  • 민윤기;;이임갑;조문재;손진훈
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.263-268
    • /
    • 1999
  • Psychoacoustic characteristics of automobile hems influence subject's subjective evaluation and psychophysiological reactions on the sounds of car horns. However, differentiation of physiological responses to commercially availablenfluence subject's subjective evaluation and psychophysiological reactions on the s horns is a complicated task due to the small contrast in technical features of horns and the influence of habituation. Using 10 college students, comparative analysis of physiological reactivity was carried out in order to identify the effect of habituation on decrement of psychophysiological responsivity, assess the ability to differentiate subjectively most and least preferred/appropriate horns according to physiological manifestations. EEG and autonomic responses to 7 automobile horns were analyzed during 3 blocks of trials (each block was varied in order for presenting stimuli and acoustic parameters of horns). It was shown that electrodermal and cardiovascular responses had different reactivity patterns to repeated stimulation. Skin conductance variables (SCL, SCR) were habituated as a function of trial. Cardiac reactivity (HR, RSA) showed no signs of habituation. In contrast, sensitization was shown in the vascular component of response (pulse volume). The temporal EEG exhibited marked habituation of fast beta band power, while alpha-blocking effect did not habituate during the course of experiment. Differentiation of physiological responses of most and least preferred/appropriate horns was possible in this study. That is, some cardiovascular reactivity variables (HR, RSA, pulse volume, etc.) were differentiated between the least and the most preferred/appropriate horns during the experiment. However, EEG and electrodermal parameters showed significant differences only during first block of trials and were later affected by habituation.

  • PDF

PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가 (Evaluation of PET Image for Fluorine-18 and Gallium-68 using Phantom in PET/CT)

  • 윤석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.321-327
    • /
    • 2018
  • The purpose of this study is to compare PET imaging performance with Fluorine-18 ($^{18}F$) and Gallium-68 ($^{68}Ga$) for influence of physical properties of PET tracer. Measurement were performed on a Siemens Biograph mCT64 PET/CT scanner using NEMA IEC body phantom and Flangeless Esser PET phantom containing filled with $^{18}F$ and $^{68}Ga$. Emission scan duration(ESD) was set to 1, 2, 3, 4 and 5min/bed for $^{68}Ga$ and 1min/bed for $^{18}F$. The PET image were evaluated in terms of contrast, spatial resolution. Under same condition, The percentage of contrast recovery measured in the phantom ranged from 16.88% to 72.56% for $^{68}Ga$ and from 27.51% to 74.43% for $^{18}F$ and The FWHM value to evaluate spatial resolution was 10.96 mm for $^{68}Ga$ and 9.19 mm for $^{18}F$. For this study, $^{18}F$ produces better image contrast and spatial resolution than $^{68}Ga$ due to higher positron yield and lower positron energy ($^{18}F$: 96.86%, 633.5 keV, $^{68}Ga$: 88.9%, 1899 keV), The physical properties of PET tracer effect on the PET image. $^{68}Ga$ image applying ESD of 3, 4, 5min/bed were showed similar to $^{18}F$ image with ESD of 1min/bed. This study suggests that increasing ESD for acquiring $^{68}Ga$ PET image seem to be similar to $^{18}F$ image.