• 제목/요약/키워드: Evaluation condition

검색결과 5,002건 처리시간 0.038초

실험계획법을 이용한 레이저 산란의 최적 조건 결정에 대한 연구 (A Study on the Optimal Condition Determination of Laser Scattering Using the Design of Experiment)

  • 한재철;김경범
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.58-64
    • /
    • 2009
  • In this paper, an inspection mechanism based on laser scattering has been developed for the surface evaluation of infrared cut-off filters, and optimum conditions of laser scattering are determined using the design of experiment. First of all, attributes and influence factors of laser scattering are investigated and then a laser scattering inspection mechanism is newly designed based on analyses of laser scattering parameters. Also, Taguchi method, one of experimental designs, is used for the optimum condition selection of laser scattering parameters and the optimum condition is determined in order to maximize the detection capability of surface defects. Experiments show that the proposed method is useful in a consistent and effective defect detection and can be applied to surface evaluation processes in manufacturing.

고속가공의 상태 감시를 위한 실험적 평가 기술 (Experimental evaluation technique for condition monitoring of high speed machining)

  • 김전하;강명창;김정석;김기태
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.84-87
    • /
    • 2001
  • The high speed machining which cam improve the production and quality has been remarkable in die/mold industry with the growth of parts and materials industries. The speed of machine tool increases, but on the other hand, the response of sensors I not being improved. Therefore, the condition monitoring techniques for the machine too, tool and workpiece in high speed machining are incomplete. In this study, characteristics of the tool edge roughness were verified from the high frequency components of cutting force signals acquired by the high speed dynamometer. Also, the experimental evaluation technique for the machinability and condition monitoring in high speed machining was established by analyzing the cutting force, acceleration and surface roughness.

  • PDF

바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가 (Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System)

  • 김세환;박종일
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

초기 재령 콘크리트의 종파 속도와 강도의 상관관계 (Correlation between Longitudinal Wave Velocity and Strength of Early-aged Concrete)

  • 이휘근;이광명;김동수
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.67-74
    • /
    • 2000
  • The usage of nondestructive testing on early-aged concrete leads to enhacned safty and allows effective scheduling of construction, thus making it possible to maximize the time and cost efficiencies. In this study, a reliable nondestructive strength evaluation method for early-aged concrete using the longitudinal wave velocity is proposed. Compression tests were performed to examine factors influencing the velocity-strength relationship of concrete, such as water-cement (w/c) ratio, fine aggregate ratio, curing temperature, and curing condition. The test results show that a change in the w/c ratio and curing temperature has minor effect on the velocity-strength relationship/ However, curing condition significantly influences the velocity-strength relationship of early-aged concrete. Moreover, the longitudinal wave velocity increases with decreasing fine aggregate ratio. It is concluded from this study that the strength evaluation of early-age concrete can be achieved by a nonlinear equation which considers the effects of curing condition and fine aggregate ratio.

층간소음저감재 장기 내구성 평가를 위한 가열시험의 문제점 및 개선방안에 관한 연구 (A study on the improvement method of heat treatment condition for the long-term stability evaluation in the floor impact isolator)

  • 박연준;이찬규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.238-243
    • /
    • 2011
  • This study compared Kd, loss factor and thickness of floor impact isolator by loading/unloading heat treatment with results by continuous loading treatment and checked problem and improvement method of heat treatment condition for the long-term stability evaluation of the floor impact isolation. As the results, it is required the change of heat treatment condition unloading now to loading as actual weigh on the floor impact isolator.

  • PDF

이상조건하에서 가정용 연료전지 시스템의 성능 및 안전성 평가에 관한 연구 (A Study on the Performance and Safety Evaluation for Residential Fuel Cell System under the Abnormal Condition)

  • 이정운;서원석;김영규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.10-13
    • /
    • 2008
  • Fuel cell systems have witnessed remarkable development in recent years as they offer a clean and efficient alternative for power generation. Testing was conducted to determine the safety performance of a residential fuel cell system when subjected to abnormal operation condition, especially for voltage sag and fuel cut. In case of voltage sag to 198V, its arriving time at rated power had shown a slight lag but there wasn't any noticeable change when operating it between rated voltage(220V) and 10% voltage sag(198V). In case of fuel cut, it also showed stable shut-down characteristics. The test results are being used to develop a new safety evaluation for residential fuel cell system.

  • PDF

차량장착용 볼트의 안전성평가 (Safety evaluation of bolt for railway vehicle equipment use)

  • 문형석;유원희;김남포
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.660-668
    • /
    • 2000
  • The stress of connection points between railway vehicle equipment and carbody is considered as one of the important railway safety factor under the vehicle service condition. If any material or equipment drop in to the rail during the service condition, the vehicle call be lose its control as well as run off the rail. The be]t safety evaluation method by using hand calculation is broadly used by manufacturer is introduced in this paper. Two different kinds of the bolt, such as regular bolt and the bolt aluminum extruded carbody use, are tested based on U.I.C according to equipment fixed. The effect of holder and base to bolt under tile loading condition is analyzed on this paper.

  • PDF

The Effect of Product Experience Through Virtual Reality on Product Evaluation

  • Jeon, Eunmi;Han, Youngjee;Woo, Hyunjin
    • Asia Marketing Journal
    • /
    • 제21권4호
    • /
    • pp.45-57
    • /
    • 2020
  • With the development of new technologies, virtual reality (VR) is emerging as a new consumer marketing platform. Yet, only a few studies have investigated VR in the consumption context. The current research explores how experiencing a product through VR influences consumer attitude and purchase intention for the product. Although assessing products in real life is believed to be more diagnostic than that through VR, the present research revealed that experiencing a product through VR could lead to a more positive attitude toward and higher purchase intention for the product. We also demonstrated that "enjoyment" has a mediating effect while evaluating the product through VR. To compare product experience through VR to that in real life, we employed the HTC Vive VR system to implement a VR environment. In the VR condition, participants evaluated plastic building blocks using a VR headset and a motion controller; and in the real life (reality) condition, they evaluted plastic building blocks printed using a 3D printer to make them look exactly the same as the blocks used in the VR condition. Finally, implications and suggestions are discussed.

공동주택의 건강성능 평가지표 개발에 관한 연구 (A Study on the Evaluation Indicators of Healthy Housing Quality of Multi-Family Housing)

  • 조성희;강나나
    • 한국주거학회논문집
    • /
    • 제22권1호
    • /
    • pp.43-55
    • /
    • 2011
  • The purpose this study is to develop indicators that measure the healthy housing condition of multi-family housing. The major findings are as follow: first, healthy housing was defined by physical, mental, social, and management aspects and proposed the conceptual model of hierarchy structure of evaluation of healthy housing by literature reviews. Second, evaluating items were selected based on literature reviews of existing indicators and preceding studies about both domestic and overseas multi-family housing. The evaluating indicators were identified as a total of 87 evaluating items which were composed of four dimensions and 16 attributes on the basis of the conceptual model. They cover comprehensive scope of the multi-family housing such as unit, building, complex, and site. Third, as the measurement, the 5-point ordinal scale measure was suggested. The evaluating measurement including measure standards, measure methods, and measure contents were developed by each evaluating items. Lastly, the weighting of evaluating indicators was developed by AHP method conducted by survey of an expert group. Items were identified as high contributors or low contributors. The weighting of these items could suggest several evaluations according to the situation. The level of healthy housing condition may be evaluated by both total evaluation and a specific field of evaluation.

브리넬 경도 표준 시험기 및 압입자국 자동 측정 장치의 장기 안정도 평가와 최적 시험조건에 관한 연구 (A Study on the Evaluation of Long Term Stability of Brinell Standard Hardness Tester and Automatic Indentation Measurement System and Optimum Test Condition)

  • 방건웅;탁내형;황농문
    • 열처리공학회지
    • /
    • 제13권1호
    • /
    • pp.10-15
    • /
    • 2000
  • Evaluation of long term stability of the Brinell standard hardness tester was carried out to secure its application as a national standard in Brinell hardness. Accuracy and repeatability in load application were tested through evaluating errors in hardness measurement of certified reference blocks. All of those requirements in KS as well as ISO specifications were satisfied by this standard hardness tester. In addition to this, long term stability test of automatic indentation measurement system was carried out. The scattering range was almost the same with its error range. To figure out an optimum test condition for better repeatability and long term stability, the effect of load variation, load application speed and time have been studied using orthogonal array experimental plan. It was found that the best combination is $30{\mu}m/s$ of load application speed and 25 seconds of load application time.

  • PDF