Evaluation on Fire Available Safe Egress Time of Commercial Buildings based on Artificial Neural Network (인공신경망 기반 상업용 건축물의 화재 피난허용시간 평가)

  • Darkhanbat, Khaliunaa;Heo, Inwook;Choi, Seung-Ho;Kim, Jae-Hyun;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.111-120
    • /
    • 2021
  • When a fire occurs in a commercial building, the evacuation route is complicated and the direction of smoke and flame is similar to that of the egress route of occupants, resulting in many casualties. Performance-based evacuation design for buildings is essential to minimize human casualties. In order to apply the performance-based evacuation design to buildings, it requires a complex fire simulation for each building, demanding a large amount of time and manpower. In order to supplement this, it would be very useful to develop an Available Safe Egress Time (ASET) prediction model that can rationally derive the ASET without performing a fire simulation. In this study, the correlations between fire temperature with visibility and toxic gas concentration were investigated through a fire simulation on a commercial building, from which databases for the training of artificial neural networks (ANN) were created. Based on this, an ANN model that can predict the available safe egress time was developed. In order to examine whether the proposed ANN model can be applied to other commercial buildings, it was applied to another commercial building, and the proposed model was found to estimate the available safe egress time of the commercial building very accurately.

Looking Back over a Decade "Final Decision Call after the Accidents of the Fukushima Nuclear Power Plant"

  • Nakajima, Isao;Kurokawa, Kiyoshi
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.147-156
    • /
    • 2020
  • The author Nakajima was involved in the field of disaster communications and emergency medical care as guest research scientist at the Fukushima Nuclear Accident Independent Investigation Commission established by the National Diet of Japan and reviewer of the Commission's report, and Kurokawa was the chairman of this Commission. Looking back over a decade, we are on the liability issue of bureaucrats and telecom operators, so it's becoming clear what was hidden at the time. The battery of NTT DoCoMo's mobile phone repeaters had a capacity of only about 24 hours, and communication failures increased after one day. The Government also failed to issue an announcement of "Vent from reactor" under the Telecommunications Act Article No. 129. This mistake lost the opportunity to use the third-party telecommunications (e.g. taxi radios). Furthermore, as a result of LASCOM (telecommunications satellite network for local governments via GEO) and a variety of unexpected communication failures, the evacuation order "Escape!" could not be notified to the general public well. As a result, the general public was exposed to unnecessary radiation exposure. Such bureaucratic slow action in emergencies is common in the response to the 2020 coronavirus.

A Study on the Use of Balcony Areas to Improve Fire Escape for Residents in Apartments (화재피난 방안 수립을 위한 공동주택 거주자의 발코니 사용실태 조사)

  • Lee, So-Young;Lee, Myung-Sik
    • Korean Journal of Human Ecology
    • /
    • v.17 no.3
    • /
    • pp.541-552
    • /
    • 2008
  • With the increase of apartments and expansion of balcony areas, fire safety issues are becoming more important. Many researchers have conducted a lot of researches to reduce vertical flame spread in the balcony when an apartment unit is in fire. However, there have rarely been studies to use balcony area as a space for fire escape and evacuation. The study aims to examine the conditions of balcony use in apartments in order to find out prevention elements from fire escape and evacuation, and to investigate residents' satisfaction with balcony. For this study, questionnaires were collected from apartment residents and workers of architectural planning and construction companies. The findings show as follows: first, the balcony is generally used as a storage in each apartment unit nowadays. Second, when fire breaks out, many storage items could disturb residents' safe escape by blocking escape route, and easily promote to spread flame vertically in the balcony.

A Study on Disaster Evacuation System in Busan Urban Transit using LoRa Wireless Network (LoRa 무선네트워크 기반 부산도시철도 재난대피 시스템 적용에 관한 연구)

  • Lee, Moo-Hyun;Park, Hee-Chul;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.417-419
    • /
    • 2016
  • Internet of things(IoT) services should be available to provide unattended operation in a remote area, long battery life, low-cost infrastructure, two-way communication platform. Urban transit in Busan is made up of the wire-based infrastructure except for voice infrastructure of transmit/receive and new data infrastructure is required for Internet of things(IoT) services. Urban transit environments in Busan were analyzed in order to apply LoRa Wireless Network(the standard communication way of IoT) and proposes a building after a Disaster Evacuation System.

  • PDF

REQUIREMENTS FOR AUTOMATED CODE CHECKING FOR FIRE RESISTANCE AND EGRESS RULE USING BIM

  • Jiyong Jeong;Ghang Lee
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.316-322
    • /
    • 2009
  • The more repetitive, complex and objective the work, the more effective automation is. Code checking is an example of this. Checking building codes through a thick set of drawings is error-prone and time-consuming. In order to overcome this problem, several organizations have initiated efforts to automate building-code checking. Initiated study mainly focused on checking codes for invalidation, required size and crash, and then area of checkable codes have been expanding. But, it has not been considered for codes regarding anti-disaster/egress, which is also issued these days. This study is about how to automatically check codes for anti-disaster and egress based on Korea building codes. The codes can be categorized as five sections: egress way, material/capability, principals of evacuation, evacuation stairway and fire protection partition. To check automatically, there are problems, such as expression of codes for egress and limitation of extractable information from the BIM model. This paper shows what problems exist and assignments to be resolved. Also, current developing processes are presented, and suggestions are made about the direction for the work that remains.

  • PDF

Visualization of wildfire based on FIRMS API (FIRMS API를 이용한 GIS기반 산불 확산정보의 시각화)

  • Lee, Byung Hyun;Son, Min Woo;Kim, Byung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.454-454
    • /
    • 2022
  • Residents near the fire site are more anxious as they rely only on media information and the government's evacuation order due to the lack of information to understand the progress of the wildfire. Therefore, in the event of a wildfire, we try to understand the inconvenience of not being able to know the progress of the fire and solve it. This makes it possible to check the progress of wildfires and the spread of debris using the system interface (API) and weather data of the thermal infrared satellite image data (NASA FIRMS, Fire Information for Resource Management System), and finally, the purpose of this study. The results are provided through the Web including GIS-based visualization to provide decision-making reference information for evacuation in the event of a forest fire from the perspective of residents.

  • PDF

A Study on the Improvement of Survival Rate of the Passengers and Crews according to FDS Analysis (FDS 분석을 통한 승객 및 선원 생존율 향상에 대한 연구)

  • Kim, Won Ouk;Kim, Jong Su;Park, Woe Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.312-317
    • /
    • 2015
  • Seafarers can confront to evacuate from the ship with many reasons such as collision, grounding and fire accident. It believes that evacuation time from ship is very important element in order to increase survival rate in the contingency circumstance, however narrow and complex structure of ship is one of obstacle element against prompt evacuation. Taking into consideration the unique structure of ship compared to the structure of other facilities, speed of fire propagation on board ship is faster than the same size of other type facilities. Therefore, measures to prompt evacuation are required. But it comes with the behavioral constraints of the crews and passengers of the nature of operating in a complex structure with narrow vessels. Therefore, in this study, we propose a formula to be analyzed by theoretical approach and simulation methods to improve the survival rate for the crew and passenger of the ship through the ship's structural modification. We analyzed the temperature rise and visibility which are the most influential effects on the life safety in the event of fire by using a three-dimensional analysis of sight-only program Fire Dynamic Simulator (FDS) as analytical tools.

A Study on Smoke Extract Vents in a Subway with Screen door by Evacuation Performance Evaluation through RSET vs. ASET based on Computer Simulations (스크린도어가 설치된 지하철 승강장의 대피안전성 평가를 통한 제연환기구의 방재성능 개선방안 연구)

  • Park, Hyung-Joo;Lee, Young-Jae;Shin, Dong-Cheol;Baek, Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.511-519
    • /
    • 2007
  • This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.

A Study on Evacuation Guidance using Location Identification Technology for Disaster (재난시 위치식별기술을 활용한 피난 유도에 관한 연구)

  • Moon, Sang-ho;Yu, Young-jung;Lee, Chul-gyoo
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.12
    • /
    • pp.937-946
    • /
    • 2017
  • Recently, urban structures including buildings are becoming increasingly large and super high-rise in order to make human life more convenient. As the number of super high-rise buildings increases, however, the risk of fire and other disasters is increasing. Especially, it is expected that deaths and injuries will be tremendous than imagined if the evacuation guidance is not provided promptly and precisely for the occupants in case of a fire in super high-rise buildings. Therefore, rapid rescue should be done for those who are in need of residence or rescue in the building. To do this, identification of the size and location of people inside the building should be preceded. To do this, first, we conduct a preliminary study on existing location tracking technologies to identify occupants. Based on this, in this paper, we will study how to improve evacuation time in case of a fire in super high-rise buildings. For this purpose, we utilize the location tracking technology to identify the number of people in real time and improve the density when a disaster such as a fire occurs.

A Study on the Smoke Removal Equipment in Plant Facilities Using Simulation (시뮬레이션을 이용한 플랜트 시설물 제연설비에 관한 연구)

  • Doo Chan Choi;Min Hyeok Yang;MIn Hyeok Ko;Su Min Oh
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.40-46
    • /
    • 2024
  • Purpose: In this study, in order to ensure the evacuation safety of plant facilities, we analyze the relationship between the height of smoke removal boundary walls, the presence or absence of smoke removal equipment, and evacuation safety. Method: Using fire and evacuation simulations, evacuation safety was analyzed through changes in the height of the smoke removal boundary wall, air supply volume and exhaust volume according to vertical dista. Result: In the case of visible drawings, if only 0.6m of boundary wall is used, the time below 5m reaches the shortest, and 1.2m of boundary width is 20% longer than when using smoke removal facilities. In the case of temperature, 1.2m is 20% longer than 0.6m when only the boundary width is used without smoke removal facilities. Conclusion: It was found that increasing the length of the smoke removal boundary wall could affect visibility, and installing a smoke removal facility would affect temperature. Therefore, it is determined that an appropriate smoke removal plan and smoke removal equipment should be installed in consideration of the process characteristics.