• Title/Summary/Keyword: EtherNET

Search Result 27, Processing Time 0.035 seconds

Cure Characteristics of Naphthalene Type Epoxy Resins for SEMC (Sheet Epoxy Molding Compound) for WLP (Wafer Level Package) Application (WLP(Wafer Level Package)적용을 위한 SEMC(Sheet Epoxy Molding Compounds)용 Naphthalene Type Epoxy 수지의 경화특성연구)

  • Kim, Whan Gun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.29-35
    • /
    • 2020
  • The cure characteristics of three kinds of naphthalene type epoxy resins(NET-OH, NET-MA, NET-Epoxy) with a 2-methyl imidazole(2MI) catalyst were investigated for preparing sheet epoxy molding compound(SEMC) for wafer level package(WLP) applications, comparing with diglycidyl ether of bisphenol-A(DGEBA) and 1,6-naphthalenediol diglycidyl ether(NE-16) epoxy resin. The cure kinetics of these systems were analyzed by differential scanning calorimetry with an isothermal approach, and the kinetic parameters of all systems were reported in generalized kinetic equations with diffusion effects. The NET-OH epoxy resin represented an n-th order cure mechanism as like NE-16 and DGEBA epoxy resins, however, the NET-MA and NET-Epoxy resins showed an autocatalytic cure mechanism. The NET-OH and NET-Epoxy resins showed higher cure conversion rates than DGEBA and NE-16 epoxy resins, however, the lowest cure conversion rates can be seen in the NET-MA epoxy resin. Although the NETEpoxy and NET-MA epoxy resins represented higher cure reaction conversions comparing with DGEBA and NE-16 resins, the NET-OH showed the lowest cure reaction conversions. It can be figured out by kinetic parameter analysis that the lowest cure conversion rates of the NET-MA epoxy resin are caused by lower collision frequency factor, and the lowest cure reaction conversions of the NET-OH are due to the earlier network structures formation according to lowest critical cure conversion.

Design of a Monitoring System for Controlling the Wet Station Equipment (Wet Station 장비를 제어하기 위한 모니터링 시스템의 설계)

  • Im, Seong-Rak;Han, Gwang-Rok;Choe, Yong-Yeop
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.5
    • /
    • pp.1385-1392
    • /
    • 1999
  • This paper describes the design of the monitoring system for monitoring the current status and indirect controlling of the Wet Station Equipment which is used for cleaning the wafer. Most of the conventional monitoring system depend on the special hardware and software. Basic design goal of monitoring system is provide the convenience for the use and the portability for the system. In order for the system to fulfil its requirements, it was designed using GUI (Graphical User Interface) facility based on the windows NT environment of IBM PC compatible and EtherNet board based on the TCP/IP protocol.

  • PDF

Implementation of Ship Area Network NMEA protocol Bridge Based on Power Line Communication (전력선통신 기반의 선박용 M모A 프로토콜 브릿지 구현)

  • Kim, Gwan-Hyung;Kang, Sung-In;Jeon, Jae-Hwan;Kwon, Oh-Hyun;Oh, Am-Suk;Cho, Hyun-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2419-2422
    • /
    • 2010
  • The current marine internal communication systems are usually composed of NMEA0183, NMEA2000, and MiTS protocols which are located on the physical layer based on RS-422, RS-485, CAN, and EtherNet. However, general vessel communication method have a weak point that must establish the extra private line. But, the power line communication has advantage over general vessel communication method as it uses AC220V/DC24V without changing line. Therefore, we will propose a new bridge based on the DC-PLC(power Line communication) technique which support the NMEA0183 protocol inside vessel network systems.

Implementation of Ship Area Network NMEA protocol Bridge Based on Power Line Communication (전력선통신 기반의 선박용 NMEA 프로토콜 브릿지 구현)

  • Kim, Gwan-Hyung;Kang, Sung-In;Jeon, Jae-Hwan;Kwon, Oh-Hyun;Oh, Am-Suk;Cho, Hyun-Cheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.577-578
    • /
    • 2010
  • The current marine communication networks are usually composed of NMEA0183, NMEA2000, and MiTS protocols which are located on the physical layer based on RS-422, RS-485, CAN, and EtherNet. This paper proposes a new bridge based on the DC power line communication technique supported from the NMEA0183 to design inside marine systems.

  • PDF

INTERACTIVE INFLUENCE OF DIETARY PROTEIN AND LIPID IN LACTATION

  • Park, C.S.;Choi, Y.J.;Fisher, G.R.;Erickson, G.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.1 no.1
    • /
    • pp.7-12
    • /
    • 1988
  • Twenty cows, by order of calving, were used in a completely randomized $2{\times}2$ factorial experiment. Variables were tow protein levels (14 and 18% crude protein) and concentration of fat (2 and 6% ether extract) in diets. Fat addition, via unprocessed whole sunflower seed, insured forage utilization in diets to meet energy requirement of cows. A total of 36 wks of lactation was subdivided into three 12-wk stages of lactation. Net energy lactation was set at 1.72, 1.57 and 1.42 Mcal/kg for each stage. Higher protein diets improved the efficiency of energy (FCM/net energy intake) which was particularly noted for diets containing high fat (85.7%). However, diets with low protein-high fat resulted in the lowest efficiency (67.7%). No difference in milk yield and butterfat was due to different levels and combinations of protein and lipid in diets. High protein diets depressed blood cholesterol and glucose compared to low-protein counterparts. Relative decline in milk production was slower for lower fat diets than for higher fat groups, especially mid to later stage of lactation. Results of this experiment tend to support our thesis on the synergistic effect of dietary protein and energy (lipid) upon efficiency of lactation.

Purified Protein and Oligopeptide Mixture Preparation from Pork Meat and Evaluation of their Nutritive Value: True Digestibility, Biological Value, and Net Protein Utilization (돈육으로 제조한 정제단백질과 Oligopeptide의 영양평가 : 소화율, 생물가, 단백질 실이용률)

  • Kim, Jong-Hee;Son, Min-Hee;Cho, Jung-Soon
    • Korean journal of food and cookery science
    • /
    • v.23 no.5
    • /
    • pp.644-649
    • /
    • 2007
  • In this study a purified protein was prepared from pork meat. The product consisted of 0.5% moisture, 3.0% ash, 5.5% ether extract and 88.7% crude protein. Also, a meat oligopeptide mixture was prepared from a pepsin digest of the protein preparation. The two preparations were colorless and odorless powders with low fat contents. The nutritive values of the pork meat protein and oligopeptide mixture were estimated by two methods, one using biological value(BV) and the other employing net protein utilization(NPU) by the nitrogen balance method. The meat oligopeptide mixture showed an excellent nutritive value by both methods. The true digestibilites of both the pork meat protein and the oligopeptide mixture were more than 98%. The above results indicate that the oligopeptide mixture is an excellent material as a dietary nitrogen source for many purposes.

Performance Improvement Strategy for Fieldbus in Industrial Wired and Wireless Network (산업용 유무선 혼합망에서 필드버스 성능향상 방안)

  • Je, Jung-Kwang;Chun, Tae-Young;Shin, Yong-Hark
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.473-475
    • /
    • 2006
  • FieldBus communication systems in industrial wired and wireless network may cause the degradation of the TCP performance due to the racket loss. TCP is particularly targeted at the wired networks, a packet loss is assumed to be caused by the network congestion. As a result, the performance of TCP decreases significantly when used over networks that exhibit a high bit error rate. In order to solve this problem, this paper designs and implements the WFSnoop mechanism which offers a fast local retransmission. The proposed mechanism does not require any changes in customer premises. Base on the simulation in the wired and wireless network environment, we analyzed the performance of the WFSnoop mechanism.

  • PDF

Effects of Roughage Neutral Detergent Fiber on Dairy Performance under Tropical Conditions

  • Kanjanapruthipong, J.;Buatong, N.;Buaphan, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.10
    • /
    • pp.1400-1404
    • /
    • 2001
  • $Holstein\;{\times}\;indigenous$ multiparous dairy cows were offered diets with increasing roughage neutral detergent fiber (NDF) contents to determine the effects on intake, milk yield and compositions. Roughage NDF contents were 15, 18, 21 and 24% dry matter (DM), and concentrate NDF content was 10% DM. Experimental treatments were isonitrogenous and isocaloric diets. Maximum and minimum temperature humidity index during the experimental period were 85.9 and 76, respectively. Intakes of DM, crude protein and net energy, 4% fat corrected milk, milk protein and average daily gain decreased with increasing roughage NDF contents (p<0.05). Intakes of ether extract (p<0.01) and dietary NDF (p>0.05) and milk fat (p<0.01) increased with increasing roughage NDF contents. The results support the conclusion that higher DM intake, optimal milk yield and compositions can be maintained with lower roughage NDF diets for dairy cows under tropical conditions.

A Study on Performance Improvement of VoIP service using QoS-Support Techniques in High-speed Internet (초고속 인터넷에서 QoS 제공 기술을 사용한 VoIP 성능 향상 연구)

  • Jung, You-Chul;Woo, Mi-Ae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.1525-1528
    • /
    • 2005
  • 본 논문에서는 초고속인터넷 망에서 VoIP 서비스 제공시 적용할수 있는 망별 QoS 제공기술을 소개하고 이러한 QoS 기술들을 이용하여 통화품질을 개선할수 있는 방안을 제시하였다 . 초고속인터넷망의 QoS 기술은 적용방법에 따라 다양한데 본 논문에서는 IEEE 802.1P, IP TOS 기술, DIFFFSERV 기술, Traffic classification & Queuing, ATM QoS 기술 등을 소개하고 이러한 기술을 사용하여 초고속인터넷망중 Metro EtherNet 망, ADSL 망을 중심으로 VoIP 서비스시 성능을 향상 할 수 있는 방안을 제시하였다

  • PDF

The On-Line Diagnostic Test of Fault Diagnosis System for Air Handling Unit (공조설비용 고장진단시스템의 실시간 진단실험)

  • 소정훈;유승신;경남호;신기석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.787-795
    • /
    • 2001
  • An experimentation on the on-line fault detection and diagnosis(FDD) system has been performed with HVAC system in he experimental building constructed inside the large scale environmental chamber. Personal computer with a home-made FDD program by pattern recognition method utilizing artificial neural network was connected on-line via Ether-net TCP/IP to the supervisory control server for HVAC system. The FDD program monitored the HVAC system by 1 minuted interval. The results showed that he FDD program detected the sudden or abrupt faults such s those in fans, sensors and heater, etc.

  • PDF