• Title/Summary/Keyword: Error monitoring system

Search Result 592, Processing Time 0.031 seconds

Displacement Measurement of a Floating Structure Model Using a Video Data (동영상을 이용한 부유구조물 모형의 변위 관측)

  • Han, Dong Yeob;Kim, Hyun Woo;Kim, Jae Min
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.2
    • /
    • pp.159-164
    • /
    • 2013
  • It is well known that a single moving camera video is capable of extracting the 3-dimensional position of an object. With this in mind, current research performed image-based monitoring to establish a floating structure model using a camcorder system. Following this, the present study extracted frame images from digital camcorder video clips and matched the interest points to obtain relative 3D coordinates for both regular and irregular wave conditions. Then, the researchers evaluated the transformation accuracy of the modified SURF-based matching and image-based displacement estimation of the floating structure model in regular wave condition. For the regular wave condition, the wave generator's setting value was 3.0 sec and the cycle of the image-based displacement result was 2.993 sec. Taking into account mechanical error, these values can be considered as very similar. In terms of visual inspection, the researchers observed the shape of a regular wave in the 3-dimensional and 1-dimensional figures through the projection on X Y Z axis. In conclusion, it was possible to calculate the displacement of a floating structure module in near real-time using an average digital camcorder with 30fps video.

Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation (혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가)

  • Kim, Yoo-Seok;Park, Seong-Min;Shim, Eun-Bo;Choi, Seong-Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

Real-time Faulty Node Detection scheme in Naval Distributed Control Networks using BCH codes (BCH 코드를 이용한 함정 분산 제어망을 위한 실시간 고장 노드 탐지 기법)

  • Noh, Dong-Hee;Kim, Dong-Seong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.5
    • /
    • pp.20-28
    • /
    • 2014
  • This paper proposes a faulty node detection scheme that performs collective monitoring of a distributed networked control systems using interval weighting factor. The algorithm is designed to observe every node's behavior collectively based on the pseudo-random Bose-Chaudhuri-Hocquenghem (BCH) code. Each node sends a single BCH bit simultaneously as a replacement for the cyclic redundancy check (CRC) code. The fault judgement is performed by performing sequential check of observed detected error to guarantee detection accuracy. This scheme can be used for detecting and preventing serious damage caused by node failure. Simulation results show that the fault judgement based on decision pattern gives comprehensive summary of suspected faulty node.

Development of Vancomycin Initial Dosage Guidelines to Achieve New Target Ranges (Vancomycin 초기 투여 용량 개선 방안)

  • Yoo, Jae-Young;Kim, Jung-Hyun;Lee, Yong-Won;Kim, Eun-Yeong;Sohn, Kie-Ho
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.221-228
    • /
    • 2010
  • In 2009, American Journal of Health-System Pharmacy (AJHP) recommended that targeting vancomycin trough concentrations of 10 mg/L or more because of therapeutic failure and potential risk of developing vancomycin resistance. Therefore, new dosage guidelines that could achieve to these higher target were needed. The aims of this study were to develop dosage guidelines targeting new vancomycin trough concentration and to evaluate the performance of these new guidelines. All data analysis were performed using NONMEM(R). Population pharmacokinetic model was first developed from vancomycin dosage and concentration data collected retrospectively during routine therapeutic drug monitoring in 441 patients, then new vancomycin dosage guidelines were developed by using the model to predict vancomycin trough and peak concentrations in a simulated dataset. The estimates, such as, vancomycin concentration trough level, time to achieve target level, mean error were performed to evaluate and compare difference between conventional dosage and new dosage guidelines. The proposed dosage guidelines were predicted to achieve 43.5% of vancomycin trough level within 10~20 mg/L, which is significantly higher than current guidelines (26.3%). Time to achieve target trough level was 19.4 hours in new guidelines comparing to 93.1 hours in the conventional dosage. Thus, new vancomycin dosage guidelines have been developed to achieve new target trough concentrations earlier and more consistently than conventional guidelines.

Efficient Compression Algorithm with Limited Resource for Continuous Surveillance

  • Yin, Ling;Liu, Chuanren;Lu, Xinjiang;Chen, Jiafeng;Liu, Caixing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.11
    • /
    • pp.5476-5496
    • /
    • 2016
  • Energy efficiency of resource-constrained wireless sensor networks is critical in applications such as real-time monitoring/surveillance. To improve the energy efficiency and reduce the energy consumption, the time series data can be compressed before transmission. However, most of the compression algorithms for time series data were developed only for single variate scenarios, while in practice there are often multiple sensor nodes in one application and the collected data is actually multivariate time series. In this paper, we propose to compress the time series data by the Lasso (least absolute shrinkage and selection operator) approximation. We show that, our approach can be naturally extended for compressing the multivariate time series data. Our extension is novel since it constructs an optimal projection of the original multivariates where the best energy efficiency can be realized. The two algorithms are named by ULasso (Univariate Lasso) and MLasso (Multivariate Lasso), for which we also provide practical guidance for parameter selection. Finally, empirically evaluation is implemented with several publicly available real-world data sets from different application domains. We quantify the algorithm performance by measuring the approximation error, compression ratio, and computation complexity. The results show that ULasso and MLasso are superior to or at least equivalent to compression performance of LTC and PLAMlis. Particularly, MLasso can significantly reduce the smooth multivariate time series data, without breaking the major trends and important changes of the sensor network system.

Sequential magnetic resonance spectroscopic changes in a patient with nonketotic hyperglycinemia

  • Shin, Ji-Hun;Ahn, So-Yoon;Shin, Jeong-Hee;Sung, Se-In;Jung, Ji-Mi;Kim, Jin-Kyu;Kim, Eun-Sun;Park, Hyung-Doo;Kim, Ji-Hye;Chang, Yun-Sil;Park, Won-Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.8
    • /
    • pp.301-305
    • /
    • 2012
  • Nonketotic hyperglycinemia (NKH) is a rare inborn error of amino acid metabolism. A defect in the glycine cleavage enzyme system results in highly elevated concentrations of glycine in the plasma, urine, cerebrospinal fluid, and brain, resulting in glycine-induced encephalopathy and neuropathy. The prevalence of NKH in Korea is very low, and no reports of surviving patients are available, given the scarcity and poor prognosis of this disease. In the current study, we present a patient with NKH diagnosed on the basis of clinical features, biochemical profiles, and genetic analysis. Magnetic resonance spectroscopy (MRS) allowed the measurement of absolute glycine concentrations in different parts of the brain that showed a significantly increased glycine peak, consolidating the diagnosis of NKH. In additional, serial MRS follow-up showed changes in the glycine/creatinine ratios in different parts of the brain. In conclusion, MRS is an effective, noninvasive diagnostic tool for NKH that can be used to distinguish this disease from other glycine metabolism disorders. It may also be useful for monitoring NKH treatment.

Design of A Stateless Minimum-Bandwidth Binary Line Code MB46d (Stateless 최소대역폭 2진 선로부호 MB46d의 설계)

  • Lee, Dong-Il;Kim, Dae-Young
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.11-18
    • /
    • 1998
  • A binary line code, called MB46d, is designed by use of the BUDA(Binary Unit DSV and ASV) cell concept to retain the property of being runlength limited, DC tree, and with a power spectral null at the Nyquist frequency. This new code is a stateless line code with a simple encoding and a decoding rule and enables efficient error monitoring. The power spectrum and the eye pattern of the new line code are simulated for a minimum-bandwidth digital transmission system where the sinc function is used as a basic pulse. The obtained power null at the Nyquist frequency is wide enough to enable easy band-limiting as well as secure insertion of a clock pilot where necessary. The eye is also substantially wide to tolerate a fair amount of timing jitter in the receiver.

  • PDF

Design of Wideband RF Frequency Measurement System with EP2AGX FPGA (EP2AGX FPGA를 이용한 광대역 고주파신호의 주파수 측정장치 설계)

  • Lim, Joong-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.7
    • /
    • pp.1-6
    • /
    • 2017
  • This paper presents the design of a frequency measurement device using ADC, EP2AGX FPGA and STM32 processor to accurately measure the frequency of a broadband high frequency signal. The ADC device used in this paper has a sampling frequency of 250 MSPS and a processing frequency bandwidth of 100 MHz. Due to its high sampling frequency, it is difficult to process in ordinary computers or processors, so we implemented the frequency measurement algorithm using the Altra EP2AGX FPGA. The measured frequency is sent to the direction detection controller in real time and fused with the phase signal to calculate the incident azimuth angle of the high frequency signal. The designed frequency measurement device is about 0.2 Mhz in frequency measurement error and 30% less than Anaren DFD-x, which is considered to contribute greatly to the design of radio monitoring and direction detection device.

Simultaneous Determination of Catecholamines, Serotonin and Their Metabolites in the Biological Sample Using HPLC/ECD (생체 시료 중 카테콜 아민류, 세로토닌 및 대사물질들의 HPLC/ECD 동시 정량분석)

  • Min, Ji-Hyun;Hahn, Young-Hee
    • YAKHAK HOEJI
    • /
    • v.55 no.4
    • /
    • pp.277-283
    • /
    • 2011
  • Simultaneous monitoring of catecholamines and serotonin with their appropriate extraction from the biological samples is required in order to understand thoroughly the regulation of the central and peripheral nervous system. In the present research the segmented gradient elution with the solid phase extraction using a C18 cartridge rather than the previous isocratic elution with alumina extraction is successfully employed to determine norepinephrine (NE), epinephrine (E), dopamine (DA), serotonin (5HT), 3,4-dihydroxyphenylacetic acid (DOPAC) and 5-hydroxyindoleacetic acid (5HIAA) simultaneously within 20 minutes using 3,4-dihydroxyhydrocinnamic aicd as the internal standard (IS). Linearities were obtained in the concentration range between $5{\times}10^{-6}M$ and $1{\times}10^{-4}M$ for all 7 compounds with detection limits of 0.6~1.9 ${\mu}M$. The present HPLC/ECD method yielded reasonable accuracy (relative error; -1.4~1.1%) and precision (relative standard deviation; 0.4~1.9%) for 9 measurements of the standard solution consisting of NE, E, DA, 5HT, DOPAC and 5HIAA compounds. Recoveries of catecholamines, serotonin and their metabolites from human serum were in the range of 57%~86%. While the concentrations of NE and 5HT in the serum of normal Sprague-Dawley rat were found as $1.4{\times}10^{-6}M$ and $2.6{\times}10^{-6}M$, respectively, the contents of NE and 5HT in the serum of the stressed rat were increased 5.6 times and 1.4 times more, respectively.

The 3D Modelling of Cultural Heritage Using Digital Photogrammetry (수치사진측량기법을 이용한 문화재의 3차원 모델링에 관한 연구)

  • 김진수;박운용;홍순헌
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.4
    • /
    • pp.365-371
    • /
    • 2003
  • Digital high resolution cameras are widely available, and are increasingly use in digital close-range photogrammetry. And photogrammetry instruments are developing rapidly and the precision is improving continuously. The building of 3D terrains of high precision are possible and the calculation of the areas or the earthwork volumes have high precision due to the development of the techlique of the spatial information system using computer. Using the digital camera which has capacity of keeping numerical value by itself and easy carrying, we analyze the positioning error according to various change of photographing condition. Also we try to find a effective method of acquiring basis data for 3D monitoring of high-accuracy in pixel degree through digital close-range photogrammetry with bundle adjustment for local terrain model generation and 3D embodiment of tumulus. In the study is about to efficient analysis of digital information data fer conservation of cultural properties.