• Title/Summary/Keyword: Error level

Search Result 2,511, Processing Time 0.029 seconds

Research on the geographic characteristics of the sea bed and the distribution of artificial reefs in Saran Bay (자란만의 해저지형 및 인공어초의 분포 조사 연구)

  • 김승철;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.214-222
    • /
    • 2001
  • A precise echosounding system to investigate the topographical characteristics of the coastal fishing ground was composed of a public-DGPS receiver, a single beam echosounder and a survey software. To confirm the usefulness of the system, a set-net fishing ground and the distribution of artificial reefs were surveyed. The results obtained are as follows : 1. The 2-D positioning error of the public-DGPS receiver with a DGPS mode and a GPS mode was 5.47 m, 7.03 m, respectively. 2. The experimented set-net fishing ground was located on the level ground at the depth of 9-10 m, a small size valley 1-2 m deep and approximately 10 m wide was found at a distance of 120 m from the set-net to the south. 3. In the artificial reefs' water area near the Jaran Bay, it was confirmed that twenty rectangular artificial reefs were established by the piece at the depth of 15-25 m and a natural reef 5-8 m high on the sea bed was located near the group of artificial reefs. 4. It was confirmed that the precise echosounding system was a useful tool in the pre-study to choice an appropriate water area to provide the artificial reef.

  • PDF

Initial Study of a Wire Mesh Tomography Sensor for Liquid/Gas Component Investigation

  • Rahiman, M.H.F.;Siow, L.T.;Rahim, R.A.;Zakaria, Z.;Ang, Vernoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2205-2210
    • /
    • 2015
  • Experimental studies have been carried out to study the principle operation of the conductive type wire-mesh tomography sensor and analyse the wire-mesh tomography sensor for the liquid/gas two-phase flow interface and void fraction distribution in a process column. The measurement of the two-phase flows in the process column is based on the cross-sectional local instantaneous conductivity. The sensor consists of two planes of parallel electrode wires with 16 electrodes each and was placed orthogonally with each plane. The sensor electrode wires were made of tinned copper wire with an outer diameter of 0.91 mm which stretched over the sensor fixture. Therefore, this result in the mesh grid size with 5.53×5.53mm2. The wire-mesh sensor was tested in a horizontal liquid/gas two-phase flows process column with nominal diameter of 95.6 mm and the sampling frequency of 5882.3529 Hz. The tomogram results show that the wire-mesh tomography provides significant results to represent the void fraction distribution in the process column and estimation error was found in the liquid/gas interface level

Estimating the Spatial Distribution of Satellite Image Classification Error Using Index of Spatial Distribution (공간분포지표를 이용한 위성영상 분류오차의 공간적 분포 평가)

  • 이병길;김용일;어양담
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.2
    • /
    • pp.129-136
    • /
    • 1999
  • The quality of image classification results is not always uniform over entire image. Thus, this study proposes the concept of ISDd (Index of Spatial Distribution by distance) and ISDs (ISD by scatteredness) for the evaluation of unevenness of result quality, and spatial distribution of satellite image classification errors. The ISDd is indexed mean distance of misclassified pixels and the ISDs is statistical indicator of scatteredness of misclassified pixels. In this study, the ISDd and the ISDs are calculated and evaluated for some satellite images, then misclassified area is extracted and the reasons of misclassification are examined. As the result of this study, using both the ISDd and the ISDs, the basis of decision on adoption/rejection of classification results is offered at sub-image level by evaluation of the local aggregation of misclassified pixels. Using Index of Spatial Distribution. as well as overall classification accuracy, users can understand the spatial distribution of misclassified pixels, and can have the additional criterion of the judgement on suitability and reliability of classification results.

  • PDF

Adaptive Group Loading and Weighted Loading for MIMO OFDM Systems

  • Shrestha, Robin;Kim, Jae-Moung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.11
    • /
    • pp.1959-1975
    • /
    • 2011
  • Adaptive Bit Loading (ABL) in Multiple-Input Multiple-Output Orthogonal Frequency-Division Multiplexing (MIMO-OFDM) is often used to achieve the desired Bit Error Rate (BER) performance in wireless systems. In this paper, we discuss some of the bit loading algorithms, compare them in terms of the BER performance, and present an effective and concise Adaptive Grouped Loading (AGL) algorithm. Furthermore, we propose a "weight factor" for loading algorithm to converge rapidly to the final solution for various data rate with variable Signal to Noise Ratio (SNR) gaps. In particular, we consider the bit loading in near optimal Singular Value Decomposition (SVD) based MIMO-OFDM system. While using SVD based system, the system requires perfect Channel State Information (CSI) of channel transfer function at the transmitter. This scenario of SVD based system is taken as an ideal case for the comparison of loading algorithms and to show the actual enhancement achievable by our AGL algorithm. Irrespective of the CSI requirement imposed by the mode of the system itself, ABL demands high level of feedback. Grouped Loading (GL) would reduce the feedback requirement depending upon the group size. However, this also leads to considerable degradation in BER performance. In our AGL algorithm, groups are formed with a number of consecutive sub-channels belonging to the same transmit antenna, with individual gains satisfying predefined criteria. Simulation results show that the proposed "weight factor" leads a loading algorithm to rapid convergence for various data rates with variable SNR gap values and AGL requires much lesser CSI compared to GL for the same BER performance.

Development of a Measure for the Dance Giftedness (무용영재성 판별도구 개발)

  • Lee, Jin-Hyo;Lee, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.161-170
    • /
    • 2012
  • Based on the qualitative analysis, 4 factors of dance giftedness were operationally defined and test items were initially developed accordingly. The preliminary test data obtained from 206 dancers was analyzed, using item analysis and a series of reliability analyses. In order to dancer the construct validity, four exploratory factor analyses were conducted for 54 items, resulting in 20 items of 4 factors; physique, dance attitude Expressiveness and creativity, movement ability. A confirmatory factor analysis conducted for 292 dancers to test the goodness-of-fit of 4 factor model revealed a satisfactory level of $x^2$, Q, root mean square residual(RMR), goodness of fit index(GFI), Tucker-Lewis index(TLI), comparative fit index(CFI), root mean square error of approximation(RMSEA). The concurrent and cross validity indices proved the validity of 20 items of 4 factors.

Measurement Uncertainty of Arsenic Concentration in Ambient PM2.5 Determined by Instrumental Neutron Activation Analysis (기기 중성자방사화분석을 이용한 대기 중 PM2.5 내 Arsenic 농도 분석의 측정 불확도)

  • Lim, Jong-Myoung;Lee, Jin-Hong;Moon, Jong-Wha;Chung, Yong-Sam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1123-1131
    • /
    • 2008
  • In this study, measurement uncertainty of instrumental neutron activation analysis was evaluated for ambient As concentration in PM2.5. Expanded uncertainties of the measurements were calculated by applying both ISO-GUM approximation and Monte Carlo Simulation(MCS). The estimate of As concentration on a specific day by the Monte Carlo Simulation differed from that of ISO-GUM approximation by less than 4%. Relative expanded uncertainties of As concentrations from a total number of 60 PM2.5 samples were also estimated to be more or less than 10% with 95% confidence level using the Monte Carlo Simulation. Sensitivity test of the measurement uncertainties showed that $\gamma$-ray counting error(62.3%), efficiency(18.5%), air volume(12.3%), neutron flux(2.3%), and absolute gamma-intensity(1.8%) are major factors of uncertainty variations.

Nondestructive Evaluation of Free Acid Content in Apples using Near-infrared Spectroscopy (근적외 분광분석법을 응용한 사과의 유리산 함량 측정)

  • Sohn, Mi-Ryeong;Cho, Rae-Kwang
    • Applied Biological Chemistry
    • /
    • v.41 no.3
    • /
    • pp.234-239
    • /
    • 1998
  • In non-destructive evaluation of free acid content in apples by near- infrared spectroscopy(NIRS), browning and heat treatment of squeezed apple juice affected to the accuracy but titrable alkali concentration did not. The free acid content in apples after harvest was able to determine using different apples in harvest time for calibration making. The result of MLR, multiple correlation coefficient(R) was 0.77 and standard error of prediction(SEP) was 0.03%. The free acid content in apples during storage was able to determine using calibration equation established with stored apples, R was 0.90 and SEP was ca. 0.04%. The prediction accuracy by LAIR was not sufficient for use of quantitative analysis of free acid content in apple, but classification of law and high level in acid content was supposed to be applicable.

  • PDF

Estimation of Inflows to Jangchan Reservoir from Outside Watershed by Minimizing Reservoir Water Storage Errors (저수량 오차에 의한 장찬저수지의 유역외 유입량 추정)

  • Noh, Jae-Kyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.5
    • /
    • pp.61-68
    • /
    • 2010
  • Jangchan reservoir is located in Okcheon county, Chungbuk province, of which watershed area is $29.4\;km^2$ from outside, and $5.1\;km^2$ from inside watershed, effective storage capacity is $392{\times}10^4\;m^3$, paddy area to be irrigated is 474 ha. To determine inflows from Keumcheon weir located in outside watershed on an optimum level, a repeated procedure which is composed of simulation of inflows to Keumcheon weir, setting of range of water taking at Keumcheon weir, simulation of inflows to Jangchan reservoir, estimation of paddy water from Jangchan reservoir, and simulation of water storages in Jangchan reservoir was selected. Parameters of DAWAST model for simulating inflows to Jangchan reservoir were determined to UMAX of 315 mm, LMAX of 21 mm, FC of 130 mm, CP of 0.018, and CE of 0.007 with absolute sum of errors in reservoir water storages minimized using unconstrained Simplex method because of no inflows data. Inflows to Keumcheon weir were simulated to $2,132{\times}10^4\;m^3$ on an annual average. Optimal range of water taking at Keumcheon weir to transfer to Jangchan reservoir were $0.81{\sim}50\;mm/km^2/d$, which were summed up to $1,397{\times}10^4\;m^3$ in 66% of total on an annual average. Inflows to Jangchan reservoir were simulated to $1,739{\times}10^4\;m^3$ on an annual average of which were 80 % from Keumcheon weir of outside watershed. Requirements to paddy water from Jangchan reservoir were estimated to $543{\times}10^4\;m^3$ on an annual average.

Implementation of Wireless Charger with the Function of Auto-Shutdown for fully Implantable Middle Ear Hearing Devices (완전 이식형 인공중이를 위한 자동 충전종료형 무선 충전장치의 구현)

  • Lee, Jang-Woo;Lim, Hyung-Gyu;Jung, Eui-Sung;Han, Ji-Hun;Lee, Seung-Hyun;Park, Il-Yong;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.539-548
    • /
    • 2007
  • In the paper, a wireless charger with the function of auto-shutdown for fully implantale middle ear hearing devices (F-IMEHD) has been designed. The wireless charger can communicate with an implant module to be turned off automatically shutdown after an internal rechargeable battery has been fully-charged by electromagnetic coupling using two coils. For the communication with an implant module, the wireless charger uses the load shift keying (LSK) method. But, the variation of the mutual inductance due to the different distance between two coils can cause the communication error in receiving the fully-charged signal from an implant module. To solve the problem, the implemented wireless charger has a variable reference generator for LSK communication. The wireless charger generates proper level of the reference voltage for a comparator using an ADC (analog-to-digital converter) and a DAC (digital-to-analog converter). Through the result of experiment, it has been confirmed that the presented wireless charger can detect signals from implantable module. And wireless charger can stop generating electromagnetic flux after an implanted battery has been fully charged in spite of variable coil distance according to different skin thickness.

Automatic Virtual Platform Generation for Fast SoC Verification (고속 SoC 검증을 위한 자동 가상 플랫폼 생성)

  • Jung, Jun-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1139-1144
    • /
    • 2008
  • In this paper, we propose an automatic generation method of transaction level(TL) model from algorithmic model to verify system specification fast and effectively using virtual platform. The TL virtual platform including structural properties such as timing, synchronization and real-time is one of the effective verification frameworks. However, whenever change system specification or HW/SW mapping, we must rebuild virtual platform and additional design/verification time is required. And the manual description is very time-consuming and error-prone process. To solve these problems, we build TL library which consists of basic components of virtual platform such as CPU, memory, timer. We developed a set of design/verification tools in order to generate a virtual platform automatically. Our tools generate a virtual platform which consists of embedded real-time operating system (RTOS) and hardware components from an algorithmic modeling. And for communication between HW and SW, memory map and device drivers are generated. The effectiveness of our proposed framework has been successfully verified with a Joint Photographic Expert Group (JPEG) and H.264 algorithm. We claim that our approach enables us to generate an application specific virtual platform $100x{\tims}1000x$ faster than manual designs. Also, we can refine an initial platform incrementally to find a better HW/SW mapping. Furthermore, application software can be concurrently designed and optimized as well as RTOS by the generated virtual platform