• Title/Summary/Keyword: Error Criteria

Search Result 580, Processing Time 0.025 seconds

The Patient Specific QA of IMRT and VMAT Through the AAPM Task Group Report 119 (AAPM TG-119 보고서를 통한 세기조절방사선치료(IMRT)와 부피적세기조절회전치료(VMAT)의 치료 전 환자별 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Kim, Jong-Ha;Park, Seung;Lee, Keun-Sub;Sohn, Seung-Chang;Shin, Young-Joo;Kim, Yon-Lae
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.255-263
    • /
    • 2012
  • The aim of this study was to evaluate the patient specific quality assurance (QA) results of intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) through the AAPM Task Group Report 119. Using the treatment planning system, both IMRT and VMAT treatment plans were established. The absolute dose and relative dose for the target and OAR were measured by using an ion chamber and the bi-planar diode array, respectively. The plan evaluation was used by the Dose volume histogram (DVH) and the dose verification was implemented by compare the measured value with the calculated value. For the evaluation of plan, in case of prostate, both IMRT and VMAT were closed the goal of target and OARs. In case of H&N and Multi-target, IMRT was not reached the goal of target, but VMAT was reached the goal of target and OARs. In case of C-shape(easy), both were reached the goal of target and OARs. In case of C-shape(hard), both were reached the goal of target but not reached the goal of OARs. For the evaluation of absolute dose, in case of IMRT, the mean of relative error (%) between measured and calculated value was $1.24{\pm}2.06%$ and $1.4{\pm}2.9%$ for target and OAR, respectively. The confidence limits were 3.65% and 4.39% for target and OAR, respectively. In case of VMAT the mean of relative error was $2.06{\pm}0.64%$ and $2.21{\pm}0.74%$ for target and OAR, respectively. The confidence limits were 4.09% and 3.04% for target and OAR, respectively. For the evaluation of relative dose, in case of IMRT, the average percentage of passing gamma criteria (3mm/3%) were $98.3{\pm}1.5%$ and the confidence limits were 3.78%. In case of VMAT, the average percentage were $98.2{\pm}1.1%$ and the confidence limits were 3.95%. We performed IMRT and VMAT patient specific QA using TG-119 based procedure, all analyzed results were satisfied with acceptance criteria based on TG-119. So, the IMRT and VMAT of our institution was confirmed the accuracy.

Estimation of Allowable Bearing Capacity and Settlement of Deep Cement Mixing Method for Reinforcing the Greenhouse Foundation on Reclaimed Land (간척지 온실기초 보강을 위한 심층혼합처리공법의 허용지내력 및 침하량 산정)

  • Lee, Haksung;Kang, Bang Hun;Lee, Kwang-seung;Lee, Su Hwan
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.287-294
    • /
    • 2021
  • In order to expand facility agriculture and reduce greenhouse construction costs in reclaimed land, a greenhouse foundation method that satisfies economic feasibility and structural safety at the same time is required. As an alternative, the allowable bearing capacity and settlement were reviewed when the DCM(Deep cement mixing) method was applied among the soft ground reinforcement methods. To examine the applicability of the greenhouse foundation, the allowable bearing capacity and settlement were calculated by applying the theory of Terzaghi, Meyerhof, Hansen, and Schmertmann. In case of the diameter of 800mm and the width and length of the foundation of 4m, the allowable bearing capacity was 179kN/m2 and the settlement was 7.25mm, which satisfies the required bearing capacity and settlement standards. The calculation results were verified through FEM(Finite element method) analysis using the Mohr-Coulomb material model. The allowable bearing capacity was 169kN/m2 and the settlement was 2.52mm. The bearing capacity showed an error of 5.6% compared to calculated value, and the settlement showed and error of 65.4%. Through theoretical calculations and FEM analysis, it was confirmed that the allowable bearing capacity and settlement satisfies the design criteria as a greenhouse foundation when the width and length of the foundation were 4m. Based on the verified design values, it is expected to be able to present the foundation design criteria for greenhouses through empirical tests such as bearing capacity tests and long-term settlement monitoring.

Why Your Manuscripts Were Rejected or Required a Major Revision: An Analysis of Asia Pacific Journal if Information Systems (MIS 논문의 '게재 불가' 및 '수정 후 재심사' 사유: Asia Pacific Journal of Information Systems 심사소견서 분석)

  • Lee, Choong-C.;Yun, Hae-Jung;Hwang, Seong-Hoon
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.179-193
    • /
    • 2009
  • As the common saying attests, a publish-or-perish world, publishing is absolutely critical for academic researchers' successful careers. It is the most objectively-accepted academic performance criteria and the most viable way to attain public and academic recognition. Asia Pacific Journal of Information Systems(APJIS) has been recognized as the most influential domestic journal in Korean MIS field since July, 1991. Therefore, publishing in APJIS means your research is original, valid, and contributive. While most researchers learn how to publish an article in APJIS through a repetitive review process, thereby improving their chance of the' accepted' through their personal trial and error experiences, such valuable lessons and know-how tend to be kept personally and rarely shared. However, useful insights into research and publication skills could be also gained from sharing others' errors, neglect, and misjudgments which are equally critical in improving researchers' knowledge in the field (Murthy and Wiggins, 2002). For this reason, other academic disciplines make systematic efforts to examine the paper review process of major journals and share the findings from these studies with the rest of the research community members (Beyer et al., 1995; Cummings et al, 1985; Daft, 1995; Jauch and Wall, 1989; Murthy and Wiggins, 2002). Recognizing the urgent need to provide such type of information to MIS research community in Korea, we have chosen the most influential academic journal, APJIS with an intention to share the answer to the following research question: "What are the common problems found in the manuscripts either 'rejected' or 'required a major revision' by APJIS reviewers?" This study analyzes the review results of manuscripts submitted to APJIS (from January, 2006 to October, 2008), particularly those that were 'rejected' or required a 'major revision' at the first round. Based on Daft's(1995) study, twelve most-likelihood problems were defined and used to analyze the reviews. The twelve criteria for classification, or "twelve problems", are as follows: No theory, Concepts and operationalization not in alignment, Insufficient definition--theory, Insufficient rationale--design, Macrostructure--organization and flow, Amateur style and tone, Inadequate research design, Not relevant to the field, Overengineering, Conclusions not in alignment, Cutting up the data, and Poor editorial practice. Upon the approval of the editorial board of APJIS, the total 252 reviews, including 11 cases of 2005 and 241 cases from July, 2006 to October, 2008, were received without any information about manuscripts, authors, or reviewers. Eleven cases of 2005 were used in the pilot test because the data of 2005 were not in complete enumeration, and the 241 reviews (113 cases of 'rejection' and 128 ones of 'major revision') of 2006, 2007, and 2008 were examined in this study. Our findings show that insufficient rationale-design(20.25%), no theory(18.45%), and insufficient definition--theory(15.69%) were the three leading reasons of 'rejection' and 'major revision.' Between these two results, the former followed the same order of three major reasons as an overall analysis (insufficient rationale-design, no theory, and insufficient definition-theory), but the latter followed the order of insufficient rationale--design, insufficient definition--theory, and no theory. Using Daft's three major skills-- 'theory skills', 'design skills', and 'communication skills'-- twelve criteria were reclassified into 'theory problems', 'design problems', and 'communication problems' to derive more practical implications of our findings. Our findings show that 'theory problems' occupied 43.48%, 'design problems' were 30.86%, and 'communication problems' were 25.86%. In general, the APJIS reviewers weigh each of these three problem areas almost equally. Comparing to other disciplines like management field shown in Daft's study, the portion of 'design problems' and 'communication problems' are much higher in manuscripts submitted to the APJIS than in those of Administrative Science Quarterly and Academy of Management Journal even though 'theory problems' are the most predominant in both disciplines.

Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

The Effect of Color Filter on the Reading Ability in Teenager with Irlen-Syndrome (얼렌증후군에서 컬러필터가 읽기능력에 미치는 영향)

  • Lee, Dong-Joon;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.125-136
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the effect of improving read speed with color filter or without color filter to improve reading disorder of teenager who were diagnosed as Meares-Irlen syndrome through survey inspection with Meares-Irlen syndrome visual stress (MISViS) score. Methods: MISViS subjects were selected from screening survey MISViS results given above 2.13 in the clinical criteria scores (MISViS score). Reading speed were measured quickly and efficiently the rate of reading via test in which randomly ordered common words are read aloud during a minute. Each of the subjects were worn a filter of the lowest concentration in each color filter group composed of 15 groups. Results: MISViS score of MISViS group and control group were 2.57 and 0.66, respectively. Results of reading speed with filter and without filter in MISViS group were $102.27{\pm}27.86$ wpm and $118.87{\pm}26.99$ wpm (p=0.001), respectively, as well as were $132.93{\pm}6.88$ wpm and $133.43{\pm}6.64$ wpm (p=0.131) in the normal group. Associated with error changes with filter and without filter between two groups, skipping in MISViS Group were from $0.25{\pm}0.62$ times to 0 times (p=0.191), Errors were from $1.83{\pm}1.69$ times to $0.17{\pm}0.38$ times (p = 0.004) and, repetitions were 0. skipping in control group were 0 times, errors were from $0.21{\pm}0.43$ times to $0.07{\pm}0.27$ times (p=0.336) and, repetitions were from $0.14{\pm}0.36$ times to 0 (p=0.165). The filter of blue series chosen in MISViS group had higher percentage (40%), whereas, subjects in normal group were more likely to prefer the filter of gray color (29%). Conclusions: This study showed that MISViS score have been used as a significant diagnosis for Irlen syndrome screening. This study found that wearing suitable color filter for MISViS patients were useful to improve learning with regard to reading. Unique color filter selection for MISViS subjects must be carefully considered since fit color filter are different personally.

Assessment of Visual satisfaction & Visual Function with Prescription Swimming goggles In-air and Underwater (도수 수경 착용시 실내와 수중에서의 시각적 만족도 및 시력 평가)

  • Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.357-363
    • /
    • 2013
  • Purpose: To investigate the visual function with prescription swimming goggles. Methods: 15 university students (mean age: $22{\pm}1.54$ years) participated, with a mean distance refractive error of RE: S-1.67 D/C-0.40 D, LE: S-1.70D/C-0.37 D. Inclusion criteria were no ocular pathology, able to wear soft contact lenses to correct their refractive error to emmetropia and able to swim. Participants were fitted with contact lenses to correct all ametropia. Subjective evaluation for satisfaction of visual acuity, asthenopia and balance were also measured using a questionnaire while wearing swimming goggles with cylinder (C+1.50 D, Ax $90^{\circ}$) compared with plano sphere outside the swimming pool area. Visual acuity was assessed using the same ETDRS chart. The prescription swimming goggles powers were assessed in random order and ranged in power from S+3.00 D to S-3.00 D in 0.50 D steps. Results: Subjective evaluation was significantly worse for the swimming goggles with cylinder than for the plano powered goggles for all 3 questions, visual acuity, asthenopia and balance. Visual acuity were significantly affected by the different power of the swimming goggles (p<0.05), but there was no significant difference between the in-air in-clinic and underwater in-swimming pool measures (p=0.173). However, visual acuity measured in the clinic was significantly better than underwater for some swimming goggle powers (+3.00, +1.00, +0.50, 0, -1.00 and -2.00 D). Conclusions: Wearing swimming goggles underwater may degrade the visual acuity compared to within air but as the difference is less than 1 line of Snellen acuity, and it is unlikely to result in significant real-life effects. Having an incorrect cylinder correction was found to be detrimental resulting in lower score of satisfaction. Considering slippery floor of swimming pool area, it can be a potential risk factor. Therefore, it is important to correct any refractive error in addition to astigmatism for swimming goggle.

Software Reliability Growth Modeling in the Testing Phase with an Outlier Stage (하나의 이상구간을 가지는 테스팅 단계에서의 소프트웨어 신뢰도 성장 모형화)

  • Park, Man-Gon;Jung, Eun-Yi
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.10
    • /
    • pp.2575-2583
    • /
    • 1998
  • The productionof the highly relible softwae systems and theirs performance evaluation hae become important interests in the software industry. The software evaluation has been mainly carried out in ternns of both reliability and performance of software system. Software reliability is the probability that no software error occurs for a fixed time interval during software testing phase. These theoretical software reliability models are sometimes unsuitable for the practical testing phase in which a software error at a certain testing stage occurs by causes of the imperfect debugging, abnornal software correction, and so on. Such a certatin software testing stage needs to be considered as an outlying stage. And we can assume that the software reliability does not improve by means of muisance factor in this outlying testing stage. In this paper, we discuss Bavesian software reliability growth modeling and estimation procedure in the presence of an imidentitied outlying software testing stage by the modification of Jehnski Moranda. Also we derive the Bayes estimaters of the software reliability panmeters by the assumption of prior information under the squared error los function. In addition, we evaluate the proposed software reliability growth model with an unidentified outlying stage in an exchangeable model according to the values of nuisance paramether using the accuracy, bias, trend, noise metries as the quantilative evaluation criteria through the compater simulation.

  • PDF

Interobserver and Intraobserver Reproducibility of SUL Measurements in Reference Organs on FDG PET/CT (FDG PET/CT 검사 시 참고장기에서 측정한, 제지방체중으로 표준화한 표준화 섭취계수의 관찰자 사이 및 관찰자 내 재현성에 대한 연구)

  • Kim, Seong Su;Shin, Yong Cheol;Lee, Sun Do;Lee, Nam Ju;Kim, Jong Cheol;Lee, Chun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Purpose: The use of SUV which should be normalized by lean body mass (LBM) is recommended for PET response criteria in solid tumors. LBM which was determined by whole body CT was used for SUV normalization (SUL) in this study. The purpose of the present study was to assess interobserver and intraobserver reproducibility of SUL measurements in reference organs. Materials and Methods: F-18 FDG PET/CT was conducted on 52 subjects and LBMs were directly determine by whole body CT for normalization of SUV. The 3 cm diameter spherical VOI, $1\times2$ cm cylindrical VOI, 2 cm diameter spherical VOI were placed in the liver, descending aorta and spleen, respectively. Experienced two observers measured SULmax and SULmean in each organ. Repeated measurements were conducted two weeks apart by observer 1 blind to previous results. Similarly, measurements were conducted on the same patients by observer 2. For assessing reproducibility(or repeatability), the paired t-test, Pearson's correlation coefficients (CC), and technical error of measurement (TEM) were calculated. Results: For interobserver reproducibility in liver SULmax and SULmean, no significant differences were found between observers(paired t-test, P=0.536, 0.293, respectively). CC and TEM for liver SULmean were 0.909 (P=0.000) and 0.067 SUL unit, respectively. Corresponding figures for liver SULmax were 0.882 (P=0.000) and 0.117 SUL unit, respectively. For intraobserver reproducibility in liver SULmax and SULmean, no significant differences were observed within observer1 (paired t-test, P=0.374, 0.268, respectively). CC and TEM for liver SULmean were 0.924 (P=0.000) and 0.061 SUL, respectively. Corresponding figures for liver SULmax were 0.908 (P=0.000) and 0.104 SUL, respectively. Similarly, no significant differences were found in SULmax and SULmean of the spleen and aorta between observers. Conclusion: The current study demonstrated that both SULmean and SULmax measurements in normal reference organs are highly reproducible. Reproducibility of SULmean in reference organs were slightly better than SULmax. Interobsever technical error of measurement was less than 0.10 SUL unit for liver SULmean, and 0.12 SUL unit for liver SULmax. Intraobsever technical error of measurement was less than 0.07 SUL unit for liver SULmean, and 0.11 SUL unit for liver SULmax.

  • PDF

Relationship between Interstate Highway Accidents and Heterogeneous Geometrics by Random Parameter Negative Binomial Model - A case of Interstate Highway in Washington State, USA (확률적 모수를 고려한 음이항모형에 의한 교통사고와 기하구조와의 관계 - 미국 워싱턴 주(州) 고속도로를 중심으로)

  • Park, Minho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2437-2445
    • /
    • 2013
  • The objective of this study is finding the relationship between interstate highway accident frequencies and geometrics using Random Parameter Negative Binomial model. Even though it is impossible to take account of the same design criteria to the all segments or corridors on the road in reality, previous research estimated the fixed value of coefficients without considering each segment's characteristic. The drawback of the traditional negative binomial is not to explain the integrated variations in terms of time and the distinct characters specific segment has. This results in under-estimation of the standard error which inflates the t-value and finally, affects the modeling estimation. Therefore, this study tries to find the relationship of accident frequencies with the heterogeneous geometrics using 9-years and 7-interstate highway data in Washington State area. 16-types of geometrics are used to derive the model which is compared with the traditional negative binomial Model to understand which Model is more suitable. In addition, by calculating marginal effect and elasticity, heterogeneous variables' effect to the accidents are estimated. Hopefully, this study will help to estiblish the future policy of geometrics.

The Study on Antenna Performancet Test for Surion Radio Installation and Optimal Positioning (수리온 통신 안테나 장착 및 최적위치 선정을 위한 안테나 성능시험에 관한 연구)

  • No, Sangwan;Lee, Soonyoung;Kim, Minsoo
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.5
    • /
    • pp.122-129
    • /
    • 2020
  • Surion is required to install radios (U/VHF-AM, VHF-FM) capable of omni-directional communication. Therefore, this paper demonstrates the antenna performance test for the installation of the Surion communication antenna and the selection of optimal location. A simulation pattern analysis was performed employing the antenna, and a coupling test was performed by creating a new evaluation criterion. In addition, the results of the pattern flight test conducted at the previously suggested 1:20 turn and separation distance ratio were observed to be normal. However, the occurrence of voice cutoff was noted in the long-distance flight test. Therefore, in this paper, 1:300 (15 NM) is proposed as a new optimal ratio for predicting the long-distance flight test results in advance. Finally, the effectiveness of the proposed evaluation criteria was verified through long-distance flight tests. Consequently, it is expected to reduce the development schedule and cost by reducing the trial and error of the performance test for the Surion model. Also, the results of this study are expected to be used as standards for the installation of communication antenna and quality tests for other helicopters.