• 제목/요약/키워드: Equivalent model

검색결과 3,124건 처리시간 0.026초

등가선형 및 비선형 납-고무받침 모델을 이용한 면진된 원전구조물의 지진응답의 비교 (Comparison of Seismic Responses of Seismically Isolated NPP Containment Structures using Equivalent Linear- and Nonlinear-Lead-Rubber Bearing Modeling)

  • 이진희;송종걸
    • 한국지진공학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-11
    • /
    • 2015
  • In order to perform a soil-isolation-structure interaction analysis of seismically isolated nuclear power plant (NPP) structures, the nonlinear behavior of a seismic isolation system may be converted to an equivalent linear model used in frequency domain analysis. Seismic responses for seismically isolated NPP containment structures subjected to a simple artificial acceleration history and different site class earthquakes are evaluated for the equivalent-linear and nonlinear models that have been applied to lead-rubber bearing (LRB) modeling. It can be observed that the maximum displacements of the equivalent linear model are larger than that of the nonlinear model. From the floor response spectrum analysis for the top of NPP containment structures, it can be observed that the spectral acceleration of an equivalent linear model at about 0.5 Hz frequency is about 2~3 times larger than that of a nonlinear model.

등가 1자유도계를 이용한 철근콘크리트 골조건물의 층간변위 응답 산정 (Estimation of Interstory Drift for Moment Resisting Reinforced Concrete Frames Using Equivalent SDOF System)

  • 강호근;전대한
    • 한국지진공학회논문집
    • /
    • 제8권5호통권39호
    • /
    • pp.25-33
    • /
    • 2004
  • 성능설계법에서 다층 건축물의 내진성능을 평가하기 위해서는 다자유도계를 등가 1자유도계로 변환할 필요가 있다. 본 논문은 다자유도계를 등가 1자유도계로 변환하여 다층 골조구조물의 층간변위 응답을 추정하는 방법을 제안한다. 본 연구의 목적은 다층 골조구조물과 등가 1자유도계의 시간이력해석을 수행하여 등가 1자유도계 변환 방법의 타당성을 확인하는 것이다. 다층 골조구조물의 시간이력해석에 의한 층간변위 응답과 등가 1자유도계에 의해 추정된 층간변위 응답을 비교하여, 등가 1자유도계에 의한 층간변위 응답에 대한 추정 방법의 타당성을 확인한다. 본 연구에서 얻어진 결과는 다음과 같다. 시간이력해석을 통하여 다자유도계를 등가 1자유도계로 변환하는 방법의 타당성을 확인할 수 있었다. 다층 골조구조물의 층간변위 응답은 비탄성 1차 모드를 이용한 등가 1자유도계의 변위응답으로부터 보다 정확히 추정할 수 있었다.

Application of steel equivalent constitutive model for predicting seismic behavior of steel frame

  • Wang, Meng;Shi, Yongjiu;Wang, Yuanqing
    • Steel and Composite Structures
    • /
    • 제19권5호
    • /
    • pp.1055-1075
    • /
    • 2015
  • In order to investigate the accuracy and applicability of steel equivalent constitutive model, the calculated results were compared with typical tests of steel frames under static and dynamic loading patterns firstly. Secondly, four widely used models for time history analysis of steel frames were compared to discuss the applicability and efficiency of different methods, including shell element model, multi-scale model, equivalent constitutive model (ECM) and traditional beam element model (especially bilinear model). Four-story steel frame models of above-mentioned finite element methods were established. The structural deformation, failure modes and the computational efficiency of different models were compared. Finally, the equivalent constitutive model was applied in seismic incremental dynamic analysis of a ten-floor steel frame and compared with the cyclic hardening model without considering damage and degradation. Meanwhile, the effects of damage and degradation on the seismic performance of steel frame were discussed in depth. The analysis results showed that: damages would lead to larger deformations. Therefore, when the calculated results of steel structures subjected to rare earthquake without considering damage were close to the collapse limit, the actual story drift of structure might already exceed the limit, leading to a certain security risk. ECM could simulate the damage and degradation behaviors of steel structures more accurately, and improve the calculation accuracy of traditional beam element model with acceptable computational efficiency.

Wall Voltage Characteristics Simulated Using an Equivalent Circuit Model for AC POPs

  • Kim, Joon-Yub;Lim, Jong-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.317-320
    • /
    • 2003
  • As a convenient means for the characterization of the wall voltage and wall charge of AC PDPs during the sustain period, an equivalent circuit model for AC PDPs is presented. The equivalent circuit model for AC PDPs consists of capacitors and thyristors. The equivalent circuit model is based on the physical structure of the AC PDP and the I-V characteristic of the discharge space. This equivalent circuit model can be easily implemented in the standard simulators such as SPICE and can easily simulate the variation of the current, charge and voltage involved in AC PDPs as the supply voltage varies.

  • PDF

5도체군 등가모델을 이용한 선로정수 예측에 관한 연구 (A Study on Estimating Line Constants Using the 5-Conductors Equivalent Model)

  • 이한민;오광해;이장무;창상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.443-445
    • /
    • 2001
  • This paper describes an estimate of line constants using the five-conductors equivalent model. Actually, a catenary system is composed of the five-conductors equivalent model. Therefore, we made up the five conductors equivalent model of a catenary system by applying a method of inverse matrix. Finally, we estimated line constants using the five-conductors equivalent model. To verify the results, we compared estimated line constants with measured those.

  • PDF

Equivalent Model Analysis of Modified Satellite Antenna for Isoflux Pattern Generation

  • Choi, Eun-Cheol;Lee, Jae Wook;Lee, Taek-Kyung;Lee, Woo-Kyung
    • Journal of electromagnetic engineering and science
    • /
    • 제14권3호
    • /
    • pp.278-283
    • /
    • 2014
  • This paper presents a theoretical approach for a modified turnstile antenna suitable for satellite communication in order to investigate the current distributions of radiators and radiation characteristics with equivalent model analysis. The proposed equivalent model is composed of an ideally horizontal dipole antenna and vertically loaded top-hat radiating elements. The required isoflux pattern with wide beamwidth has been achieved by attaching top-hat elements to the main radiators. In addition to illustrating radiation patterns, electrical performances like current distributions have been analyzed by mathematically manipulating the equations derived from the equivalent horizontal and vertical dipole model.

2차원 등가 모델을 이용한 Claw-pole type 발전기의 특성 해석 (Characteristics analysis of Claw-pole type generator using 2D equivalent model)

  • 권순오;이지영;홍정표;임양수;허윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.911-913
    • /
    • 2004
  • This paper presents characteristic analysis of claw-pole type generator. The analysis is performed using 2D equivalent model by 2D FEM. 3D FEM is used to check whether 2D equivalent model reflects the magnetic characteristics of the actual machine. Initially, 2D equivalent model of the claw-pole type generator is designed only by 3D geometry. Using 2D equivalent model, back emf characteristics are estimated and compared to measurements. The analysis results agree with measurements well and take less time comparing to 3D FEM.

  • PDF

Determination of equivalent blasting load considering millisecond delay effect

  • Song, Zhan-Ping;Li, Shi-Hao;Wang, Jun-Bao;Sun, Zhi-Yuan;Liu, Jing;Chang, Yu-Zhen
    • Geomechanics and Engineering
    • /
    • 제15권2호
    • /
    • pp.745-754
    • /
    • 2018
  • In the analysis of the effects of rock tunnel blasting vibration on adjacent existing buildings, the model of simplified equivalent load produces higher calculation result of vibration, due to the lack of consideration of the millisecond delay effect. This paper, based on the static force equivalence principle of blasting load, proposes a new determination method of equivalent load of blasting vibration. The proposed method, based on the elastic-static force equivalence principle of stress wave, equals the blasting loads of several single blastholes in the same section of millisecond blasting to the triangle blasting load curve of the exploded equivalent elastic boundary surface. According to the attenuation law of stress wave, the attenuated equivalent triangle blasting load curve of the equivalent elastic boundary is applied on the tunnel excavation contour surface, obtaining the final applied equivalent load. Taking the millisecond delay time of different sections into account, the time-history curve of equivalent load of the whole section applied on the tunnel excavation contour surface can be obtained. Based on Sailing Tunnel with small spacing on Sanmenxia-Xichuan Expressway, an analysis on the blasting vibration response of the later and early stages of the tunnel construction is carried out through numerical simulation using the proposed equivalent load model considering millisecond delay effect and the simplified equivalent triangle load curve model respectively. The analysis of the numerical results comparing with the field monitoring ones shows that the calculation results obtained from the proposed equivalent load model are closer to the measured ones and more feasible.

Immunohistochemical analysis of effects of UVA exposure to the human fibroblasts in the skin equivalent model

  • Kazuhiro Shimizu;Fumihide Ogawa;Bae, Sang-Jae;Yoichiro Hamasaki;Ichiro Katayama
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.500-502
    • /
    • 2002
  • In vitro and in vivo studies have reported the induction of matrix metaloproteinase (MMP)-1 in the fibroblasts by ultraviolet (UV) A irradiation. We constructed the skin equivalent model using HaCaT cells as keratinocytes and human neonatal dennal fibroblasts as fibroblasts in the present study. The induction of MMP-l in the fibroblasts was confirmed immunohistochemically 6 hours after UVA irradiation using this model. This model was simply composed of human keratinocytes and fibroblasts. To our knowledge, there have been a few papers concerning the skin equivalent model in the field of photobiology. The effect of UVA exposure to fibroblasts through keratinocytes was examined using this model. The cross-talk can be examined between keratinocytes and fibroblasts. This model can be a useful tool in the field of photobiology.

  • PDF

광대역 수중 음향 압전 진동체의 등가회로 모델링 (Equivalent Circuit Modeling of Wideband Underwater Acoustic Piezoelectric Vibrator)

  • 조치영;김원호;윤형규
    • 소음진동
    • /
    • 제6권5호
    • /
    • pp.645-652
    • /
    • 1996
  • In this paper an identification method is presented to obtain the equivalent electric circuit model of a wideband underwater acoustic piezoelectric vibrator. Unknown parameters involved in the equivalent circuit are indentified using the measured electrical admittances in air. The proposed method is applied to an example transducer. The validity of equivalent circuit model is demonstrated by the comparison between the experimental measurements and analytical calculations of TVR(transmitting voltage response) in water.

  • PDF