Power Integrity and Shielding Effectiveness Modeling of Grid Structured Interconnects on PCBs

  • Kwak, Sang-Keun;Jo, Young-Sic;Jo, Jeong-Min;Kim, So-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.320-330
    • /
    • 2012
  • In this paper, we investigate the power integrity of grid structures for power and ground distribution on printed circuit board (PCB). We propose the 2D transmission line method (TLM)-based model for efficient frequency-dependent impedance characterization and PCB-package-integrated circuit (IC) co-simulation. The model includes an equivalent circuit model of fringing capacitance and probing ports. The accuracy of the proposed grid model is verified with test structure measurements and 3D electromagnetic (EM) simulations. If the grid structures replace the plane structures in PCBs, they should provide effective shielding of the electromagnetic interference in mobile systems. An analytical model to predict the shielding effectiveness (SE) of the grid structures is proposed and verified with EM simulations.

Comparative analysis for the corrosion susceptibility of copper alloys in sandy soil

  • Galai, Mouhsine;Benqlilou, Hanane;Touhami, Mohamed Ebn;Belhaj, Tounsi;Berrami, Khalifa;El Kafssaoui, Hassan
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.164-174
    • /
    • 2018
  • Corrosion of copper alloys (copper, bronze and brass) in soil was evaluated at ambient temperature using various methods such as electrochemical impedance spectroscopy (EIS), polarization curves and Scanning Electron Microscopy (SEM) coupled with Energy Dispersive Spectroscopy microanalysis measurements. Three equivalent circuits were separately used to interpret the obtained impedance spectra. The EIS measurements indicated that the polarization resistance of all electrodes increases with increasing the immersion time. SEM showed a presence of three layers of corrosion products with various composition and morphology covering each electrode. In addition, it was found that at 20% of moisture content the $R_p$ values and the current density of all electrodes in the studied soil give the following order: copper > bronze > brass. Good consistency between the data obtained from EIS and PP measurements was observed.

PQ Control of Micro Grid Inverters with Axial Voltage Regulators

  • Chen, Yang;Zhao, Jinbin;Qu, Keqing;Li, Fen
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1601-1608
    • /
    • 2015
  • This paper presents a PQ control strategy for micro grid inverters with axial voltage regulators. The inverter works in the voltage-controlled mode and can help improve the terminal power quality. The inverter has two axial voltage regulators. The 1st regulator involves the output voltage amplitude and output impedance, while the 2nd regulator controls the output frequency. The inverter system is equivalent to a controllable voltage source with a controllable inner output impedance. The basic PQ control for micro grid inverters is easy to accomplish. The output active and reactive powers can be decoupled well by controlling the two axial voltages. The 1st axial voltage regulator controls the reactive power, while the 2nd regulator controls the active power. The paper analyses the axial voltage regulation mechanism, and evaluates the PQ decoupling effect mathematically. The effectiveness of the proposed control strategy is validated by simulation and experimental results.

A Study on the TRV(BTF) of Circuit Breakers According to Install Current Limit Reactors (345kV 고장전류 저감을 위한 한류리액터 설치시 차단기 TRV(모선 고장시) 검토)

  • Kwak, J.S.;Park, H.S.;Shim, E.B.;Ryu, H.Y.;Lee, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.368-370
    • /
    • 2005
  • Due to the tendency towards large capacity and complexity of power system, an enhancement of power system equipment make a system impedance to be low in power system. Generally if an equivalent impedance of system becomes lower, a system stability will be better. But the fault current becomes very larger. The 345kV ultra-high voltage system will use current limit reactors(CLR) in a transmission line or a bus in substation to limit the magnitude of fault current. The CLR makes a significant contribution to the severity of the transient recovery voltage(TRV) experienced by feeder and bus circuit breakers on clearing feeder faults. Based on the conclusions of an investigation of actual circuit breaker failures while performing this duty, the mitigation of the transient recovery voltage associated with the reactors is described. Therefore in this article we simulated the TRV by EMTP at Bus Terminal Fault.

  • PDF

Comparison of FDTD Simulation Results with Measurement Data of a Ground-Penetrating Radar (지하침투 레이더의 FDTD 모의계산 결과와 측정자료의 비교)

  • Hyun, Seung-Yeup;Kim, Se-Yun;Kim, Young-Sik
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.1-8
    • /
    • 1999
  • A complete electromagnetic simulation for a ground-penetrating radar(GPR) is implemented by employing 3-dimensional dispersive finite-difference time-domain(FDTD) method. The presented simulation model includes the cavity-backed bow-tie antennas, which are terminated by resistors. And an equivalent cirvuit consisting of the input impedance of the antenna and the characteristic impedance of the feed line is used to calculate the response in the receiving antenna. Actual emasurements of a GPR system including our manufactured bow-tie antenna pair are performed just above dry sand contained in a PVC tank. It is confirmed that the FDTD simulation results agree well with the actual measurement data.

  • PDF

Effects of the Polarization Resistance on Cyclic Voltammograms for an Electrochemical-Chemical Reaction

  • Chang, Byoung-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.146-151
    • /
    • 2015
  • Here I report an electrochemical simulation work that compares voltammetric current and resistance of a complex electrochemical reaction over a potential scan. For this work, the finite element method is employed which are frequently used for voltammetry but rarely for impedance spectroscopy. Specifically, this method is used for simulation of a complex reaction where a heterogeneous faradaic reaction is followed by a homogeneous chemical reaction. By tracing the current and its polarization resistance, I learn that their relationship can be explained in terms of rate constants of charge transfer and chemical change. An unexpected observation is that even though the resistance is increased by the rate of the following chemical reaction, the current can be increased due to the potential shift of the resistance made by the proceeding faradaic reaction. This report envisions a possibility of the FEM-based resistance simulation to be applied to understand a complex electrochemical reaction. Until now, resistance simulations are mostly based on equivalent circuits or complete mathematical equations and have limitations to find proper models. However, this method is based on the first-principles, and is expected to be complementary to the other simulation methods.

A study on the effect of $TiO_2$ to the characterization of PTC thermister (PTC서미스터의 특성에 미치는 $TiO_2$의 영향에 관한 연구)

  • 신태현;김영조;이기택
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.83-89
    • /
    • 1995
  • In this paper, the specimens-($Ba_{0.997}$ L $a_{0.003}$)Ti $O_{3}$ + xTi $O_{2}$, x=0.005, 0.01, 0.02, 0.03[mol]- were fabricated by a solid-state reaction method which is easy in microstructure control and good in mass production. Their crystalline structures and microstructures were analysed, and electrical properties were investigated. The perovskite-crystalline structure is confirmed by XRD, and it is exhibited by SEM that the grain grows with an addition of Ti $O_{2}$. Resistivity decreases with increasing sinteiing temperature, and the specimen of ($Ba_{0.997}$ L $a_{0.003}$)Ti $O_{3}$ + 0.02Ti $O_{2}$ sintered at 1350.deg. C shows the best PTC effects. The complex impedance plots exhibit the serial equivalent circuit of ( $R_{gb}$ / $C_{gb}$ ) and $R_{g}$ it is realized that PTC effect is attributed to the resistivity of grain boundary.ary.y.

  • PDF

A Study on the Design of 26GHz Band Thin Duplexer (26GHz 대역 박막 Duplexer 설계에 관한 연구)

  • Yoon Jong-nam;Lee Hyun-Ju;Oh Young-Bu;Lee Cheong-Won;Kim Ki-Don;Lee Jeong-Hae
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.208-213
    • /
    • 2003
  • In this paper, we have designed the duplexer using non-radiative dielectric (NRD) guide in millimeter band. The designed duplexer is composed of two stepped-impedance filters and T-junction. Stepped-impedance filters are designed with an equivalent circuit model of evanescent waveguide and the T-junction is optimized to minimize return loss. The characteristics of duplexer shows a good agreement with the expected results.

  • PDF

Ionization Behaviors by Types of Soil due to Lightning Impulse Voltages in a Hemishperical Electrode System (반구형 전극계에서 뇌임펄스전압에 의한 토양의 종류별 이온화 특성)

  • Lee, Kyu-Sun;Park, Geon-Hun;Kim, Hoe-Gu;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.119-125
    • /
    • 2009
  • This paper deals with the characteristics of soil ionization affecting the dynamic performance of grounding systems under lightning impulse voltage. A concentric hemispherical electrode system was employed in order to facilitate the field calculation and analysis of the experimental results. The parameters such as the ionization threshold and breakdown field intensity, the pre-ionization and the post ionization resistances, the time-lag to ionization, the transient impedance, the equivalent ionized radius for various soil media were measured and analyzed. The dynamic characteristics of ionization processes under lightning impulse voltage are strongly dependent on the types of soil and water content. As a result, a soil ionization reduces the ground resistance and there is a little effect of applied impulse polarity on the soil ionization threshold field intensity. Although the ionization threshold field intensity of wet clay with 30% water content is the highest, its ionized zone was found to be the smallest amongst the test samples.

Evaluation and Comparison of the Low-Frequency Oscillation Damping Methods for the Droop-Controlled Inverters in Distributed Generation Systems

  • Tao, Yong;Deng, Yan;Li, Guangdi;Chen, Guipeng;He, Xiangning
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.731-747
    • /
    • 2016
  • The droop-based control strategy is widely applied in the interfacing inverters for distributed generation. This can be a problem since low-frequency stability issues may be encountered in droop-based microgrid. The objective of this paper is to classify, evaluate and compare various low-frequency damping methods. First, low-frequency stability problems are analyzed and an equivalent model of a droop-controlled inverter is investigated to classify the damping methods into the source-type damping strategies and the impedance-type damping strategies. Moreover, the lead-lag compensation network insertion control is proposed as a beneficial part of the source-type damping strategies. Then, the advantages and disadvantages of the different types of damping methods are theoretically evaluated and experimentally tested. Furthermore, the damping methods are comprehensively compared to illustrate the application field of each method. Finally, the synthesis of different damping methods to enhance the low-frequency stability is discussed and experimental validation is presented.