• 제목/요약/키워드: Equivalent Continuous Noise Level

검색결과 29건 처리시간 0.023초

노래방 소음 및 난청가능성의 인간공학적 평가와 청각보호방안 (Erogonomic assessment of "Noraebang" noise and potential hearing-loss and hearing protection strategies)

  • 박민용
    • 대한인간공학회지
    • /
    • 제15권1호
    • /
    • pp.79-90
    • /
    • 1996
  • A research project was conducted to assess the levels of noise exposed to "Noraebang" users and potential hazards to noise-induced hearing loss due to commercial Noraebang noise. A two-way, mixed-factors factorial design was employed for the experiment using independent variables of "noise source" (no- singer, 1-singer, and 2-singer conditions) and "music type" (Trot, Ballad, and Rock music) with 18 normal hearing subjects. Each singer group sang 5 popular songs of each music type in each signing condition, whereas background music was just played for the no-singer condition. For each music played/sung, equivalent continuous sound pressure levels and maximum sound pressure levels were measured for data analysis purposes. Pure-tone audiometry was applied for measuring subjects' hearing threshold levels before and after exposure to Noraebgang noise. The statistical analyses indicate that average continuous noise levels due to Noraebang leisure environment were very serious, especially when two people were singing (higher than 95 dBA). Furthermore, maximum noise levels often exceeded the OSHA's non-premissible 115 dBA level. Worse yet, hearing loss assessment implies that Noraebang facilities may pose a serious threat to noise-induced hearing loss, based on 6-8 dB loss at 125 Hz and 8 dB loss at 4000 Hz after about 1-hour Noraebang noise exposure.

  • PDF

고속철도의 소음 특성과 전파현상 (Highspeed Train : Sound Power and Noise Propagation Characteristics)

  • 김정태;은희준
    • 소음진동
    • /
    • 제6권3호
    • /
    • pp.349-355
    • /
    • 1996
  • For a rail traffic noise, a typical source has a length of 200m - 400m so that the noise pollution areas have been located in the transition regions where the sound level drops between 3dB/dd and 6dB/dd. Therefore, in this region, parameters such as a horizontal distance from the track, the geometry of the ground surface, the environmental effect, and the boundary impedance condition play import roles, especially in our nation's situation. In this study, modelling techniques for the finite length of noise source have been investigated in order to evaluate the rail traffic noise level. Then. noise correction value .${\Delta}$SPL for various location in the track region is represented by the non-dimensionalized horizontal and parallel distance from the track. As an application, a high speed train is examined. Beas on the noise data measured for a Eurostar in France, the sound power value per unit length $H_1$is calcuated. It turns out that$H_1$is 109 dB. Overall sound power from the highspeed train to be serviced in our country is expected to 135 dBA.

  • PDF

국내 항공기 소음 평가방법에 관한 실험적 연구 (A Study on the Evaluation Method of Aircraft Noise)

  • 이태강;송국곤;김항;장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.421-424
    • /
    • 2007
  • Currently domestic criteria for the aircraft noise is being adapted WECPNL(weighted equivalent continuous perceived noise level), while internationally preferred method is $L_{dn}$ which is based on from $L_{eq}$ and can also evaluate environmental noise. WECPNL used in domestic as an evaluation metric is only for the aircraft noise. It is, therefore, not adequate for the evaluation of residents' injury, moreover, it is very difficult to measure the aircraft noise by WECPNL due to the complicated calculating procedures as long as automatic measuring system is not used. Accordingly, this study aims to propose alternative evaluation metric for the aircraft noise. To achieve this purpose, WECPNL, $L_{eq}$, $L_{dn}$, other metrics and criteria were compared and analyzed.

  • PDF

항공기 소음의 평가 척도에 대한 비교 연구 (A compare study on the Evaluation Method of Aircraft Noise)

  • 전지현;안병옥;송민정;장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.703-706
    • /
    • 2001
  • Currently domestic criteria for the aircraft noise is being adapted WECPNL(weighted equivalent continuous perceived noise level), while internationally preferred method is which is originated from $L_{eq}$ and can evaluate even environmental noise. WECPNL used in domestic as a evaluation method is only for the aircraft noise. It is, therefore, not adequate for the evaluation of residents' injury, moreover, it is very difficult to measure the aircraft noise with WECPNL due to the complicated calculating procedures as long as automatic measuring system is not used. Accordingly, this study aims to propose alternative evaluation method for the aircraft noise. To achieve this purpose, the data measured by automatic measuring system were gathered and calculated with three evaluation methods: WECPNL, $L_{eq}$ and $L_{dn}$ and the results calculated from different methods were compared and analyzed.

  • PDF

Interior Noise Characteristics in Japanese, Korean and Chinese Subways

  • Soeta, Yoshiharu;Shimokura, Ryota;Jeon, Jin Yong;Lee, Pyoung Jik
    • International Journal of Railway
    • /
    • 제6권3호
    • /
    • pp.120-124
    • /
    • 2013
  • The aim of this study was to clarify the characteristics of interior noise in Japanese, Korean, and Chinese subways. The octave-band noise levels, A-weighted equivalent continuous sound pressure level ($L_{Aeq}$) and parameters extracted from interaural cross-correlation/autocorrelation functions (ACF/IACFs) were analyzed to evaluate the noise inside running train cars quantitatively and qualitatively. The average $L_{Aeq}$ was 72-83 dBA. The IACF/ACF parameters of the noise showed variations in their values, suggesting they are affected by the characteristics of the trains running, wheel-rail interaction, and cross-section of the tunnels.

UH60 헬기 조종사의 피폭진동 측정 및 평가 결과 (Measurements of Whole-body Vibration Exposed from and Their UH60-helicopter Analysis Results)

  • 정완섭;변주현
    • 한국소음진동공학회논문집
    • /
    • 제15권12호
    • /
    • pp.1327-1331
    • /
    • 2005
  • This Paper addresses what amount of whole-body vibration is exposed to Korean pilots of UH60 helicopters during their mission flight. To measure the expose4 whole-body vibration, the 12-axis whole-body vibration measurement system was used. It enables the direct measurement of whole-body vibration exposed from the body contact area consisting of the feet, hip and back. The measured 12-axis vibration signals were used to evaluate the vibration comfort level experienced by the pilots of UH60 helicopters. The evaluated vibration comfort level is found to be closeto 0.74-0.79m/s, which is equivalent to the semantic scale of 'fairly uncomfortable'. To assess the health effects of whole-body vibration exposed to Korean pilots of UH60 helicopters during their mission flight, the rms-based and VDV(vibration dose value)-based evaluation schemes, recommended by ISO 2631-1:1977, were exploited in this work. The evaluated results indicate that Korean pilots cannot avoid the fatigue-decreased proficiency limit after two-hour continuous flight. The whole-body vibration level exposed from the UH60 helicopters during continuous 10-hours mission flight is found to reach to the vibration exposure limit.

소음측정방법에 따른 평가소음도 비교 (A Comparison of Noise Level by Noise Measuring Methods)

  • 심철구;노재훈;박정균
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.128-136
    • /
    • 1995
  • The purpose of this study is to evaluate the difference of noise level according to noise measuring methods in the noisy working environments. Sound pressure level(SPL), equivalence sound level(Leq) and personal noise exposure dose(Dose) in the fifty-nine unit workplaces of the twenty-eight industries were measured and relating factors which were affected noise level were investigated. The results were as follows ; 1. The noise levels were $88.70{\pm}5.68dB(A)$ by SPL, $89.07{\pm}5.41dB(A)$ by Leq and $89.07{\pm}5.69$ by Dose. The differences of noise levels by three measuring methods were statistically significant(P<0.001) by repeated measure ANOV A. 2. Comparing with noise levels by general classes of noise exposure, noise levels of continuous noise were $89.14{\pm}5.19dB(A)$ by SPL, $89.45{\pm}4.65dB(A)$ by Leq and $90.04{\pm}5.09$ by Dose. Noise levels of intermittent noise were $87.90{\pm}6.52dB(A)$ by SPL, $88.40{\pm}6.63dB(A)$ by Leq and $90.10{\pm}6.80$ by Dose. The differences noise level of noise measuring methods by general classese of noise exposure were statistically not significant by repeated measure ANOV A. 3. Interaction between general classese of noise exposure and noise measuring methods for noise level was not statistically significant by repeated measure ANOVA. And the noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001) 4. Comparing with noise levels by unit workplace size, noise levels of large unit workplace were $90.73{\pm}5.87dB(A)$ by SPL, $91.32{\pm}5.50dB(A)$ by Leq and $91.82{\pm}6.06$ by Dose and noise levels of middle unit workplace were $88.31{\pm}5.26dB(A)$ by SPL, $88.41{\pm}4.83dB(A)$ by Leq and $89.69{\pm}5.05$ by Dose. And noise levels of small unit workplace were $94.89{\pm}4.10dB(A)$ by SPL, $85.35{\pm}4.11dB(A)$ by Leq and $86.87{\pm}4.98$ by Dose. The noise level differences of noise measuring methods by unit workplace size were statistically significant by repeated measure ANOV A(P<.05). 5. The noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001). But Interaction between workplace size and noise level measuring methods for noise level was not statistically significant by repeated measure ANOVA. According to the above results, there was a difference of the noise level among the three measuring methods. Therefore we must use the personal noise exposure dose using by noise dose meter, possible, to prvent occupational hearing loss in noisy working environment.

  • PDF

IEC 규격에 따른 풍력 터빈 소음의 현장 실증 (Field Test and Evaluation of Wind Turbine Noise according to IEC Standards)

  • 정철웅;정성수;정완섭;신수현;전세종;이생희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.579-582
    • /
    • 2005
  • The sound measurement techniques in IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang-Lee and 650 kW WTG at Hangwon-Lee in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure level s (ECSPL) of 650 kW WTG at Hangwon vary more widely with speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade-rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

항공기 소음 환경 기준 설정을 위한 연구 (A Study on the Establishment of the Environmental Noise Criteria for Aircraft)

  • 김선우;장길수;이수갑;송민정;장세명;전지현;안병옥
    • 한국소음진동공학회논문집
    • /
    • 제12권6호
    • /
    • pp.420-430
    • /
    • 2002
  • Rating scales for environmental noise are varied in their calculation procedure. Among them WECPNL (weighted equivalent continuous perceived noise level) is the rating scale for aircraft noise currently being used in domestic and applied only for aircraft noise. However $L_{dn}$ calculated from $L_{eq}$ $L_{eq}$ is used as a rating scale for not only aircraft noise but also environmental noise. Besides, it is easy to calculate and internationally preferred. It is, therefore, not adequate for the evaluation of residents' exposure. Moreover it is very difficult to measure the aircraft noise by WECPNL due to the complicated calculating procedures if automatic measuring system is not used. Accordingly. this study aims to propose alternative evaluation procedure for the aircraft noise. To achieve this purpose, the data measured by automatic measuring system were gathered and calculated with three evaluation procedures : WECPNL $L_{eq}$ and $L_{dn}$, and the results calculated from different methods were compared and analyzed.

Noise in hospital rooms and sleep disturbance in hospitalized medical patients

  • Park, Marn Joon;Yoo, Jee Hee;Cho, Byung Wook;Kim, Ki Tae;Jeong, Woo-Chul;Ha, Mina
    • Environmental Analysis Health and Toxicology
    • /
    • 제29권
    • /
    • pp.6.1-6.6
    • /
    • 2014
  • Objectives Hospitalized patients are vulnerable to sleep disturbances because of environmental stresses including noise. While most previous studies on hospital noise and sleep have been performed for medical machines in intensive care units, there is a limited data for patients hospitalized in medical wardrooms. The purpose of present study was to measure noise level of medical wardrooms, identify patient-perceived sources of noise, and to examine the association between noise levels and sleep disturbances in hospitalized patients. Methods Noise dosimeters were used to measure noise level in 29 inpatient wardrooms at a university hospital. Sleep pattern and disturbance were assessed in 103 hospitalized patients, using the Pittsburgh Sleep Quality Index (PSQI) and Leeds Sleep Evaluation Questionnaire. Results The mean equivalent continuous noise level for 24 hours was 63.5 decibel A (dBA), which was far higher than 30 dBA recommended by the World Health Organization for hospital wardrooms. Other patients sharing a room were perceived as the most common source of noise by the patients, which was usually preventable. Of the patients in the study, 86% had bad sleep as assessed by the PSQI. The sleep disturbance was significantly correlated with increasing noise levels in a dose response manner. Conclusions Systemic organizational interventions are needed to keep wardrooms private and quiet to reduce sleep disturbance.