Abstract
Currently domestic criteria for the aircraft noise is being adapted WECPNL(weighted equivalent continuous perceived noise level), while internationally preferred method is which is originated from $L_{eq}$ and can evaluate even environmental noise. WECPNL used in domestic as a evaluation method is only for the aircraft noise. It is, therefore, not adequate for the evaluation of residents' injury, moreover, it is very difficult to measure the aircraft noise with WECPNL due to the complicated calculating procedures as long as automatic measuring system is not used. Accordingly, this study aims to propose alternative evaluation method for the aircraft noise. To achieve this purpose, the data measured by automatic measuring system were gathered and calculated with three evaluation methods: WECPNL, $L_{eq}$ and $L_{dn}$ and the results calculated from different methods were compared and analyzed.