Journal of electromagnetic engineering and science
/
v.4
no.1
/
pp.30-36
/
2004
We determined equivalent circuit parameters of a 1.5 cell S-band RF gun cavity from the resonant characteristics of its decoupled cavities(half cell and full cell) using the code SUPERFISH. Equivalent circuit parameters of the 1.5 cell RF gun cavity resonated in the 0-mode were obtained easily from the circuit parameters of each decoupled cavities. In order to obtain equivalent circuit parameters for the $\pi$ -mode cavity, we calculated the differences of the resonant frequencies and the equivalent resistances between the 0- and $\pi$ -modes with slight variations of the radius and thickness of the coupling iris. From those differences, we obtained R/Q value and equivalent resistance of the $\pi$ -mode, which are directly related to the equivalent circuit parameters of the coupled cavity. Using calculated R/Q value, we can express equivalent inductance, capacitance and resistances of the RF gun cavity resonated in the $\pi$ -mode, which can be useful for analyzing coupled cavities in a steady state.
Journal of the Korea Institute of Military Science and Technology
/
v.12
no.3
/
pp.282-289
/
2009
This paper presents an estimation technique of the equivalent circuit parameters for an underwater acoustic piezoelectric transducer from the measured impedance. Estimated equivalent circuit can be used for the design of the impedance matching network of the sonar transmitter. A fitness function is proposed to minimize the error between the calculated impedance of the equivalent circuit and the measured impedance of the transducer. The equivalent circuit parameters are estimated by using the fitness function and the PSO(Particle Swarm Optimization) algorithm. The effectiveness of the proposed method is verified by the applications to a sandwich-type transducer and a dummy load. In addition, the impedance matching network is also designed by using the estimated equivalent circuit model.
The Transactions of the Korean Institute of Electrical Engineers P
/
v.59
no.4
/
pp.358-363
/
2010
This paper proposes a step-by-step method of determining the parameters of equivalent circuit which is considered the no load losses for the single phase induction motor which has the starting winding. This method is comprised of three steps, and the stator resistance which is measured by the method of voltage drop is treated as constant and the stator and the rotor leakage reactances are assumed to be the same in every step. The test results of no load and locked rotor test are used in the 1st and 2nd step, and the ratings of name plate of the motor are needed in the 3rd step. In the 1st step, the traditional equivalent circuit parameters are directly calculated by no load and locked rotor conditions. In the next step, five nonlinear simultaneous equations for five unknown parameters can be set up by no load and locked rotor equivalent circuits. These equations are solved by using the initial parameters obtained by the 1st step parameters. In the final step, three nonlinear simultaneous equations for rotor winding resistance, leakage reactance and no load losses component resistance can be set up by equivalent circuit under the rated operation. Three parameters are solved by using the 2nd step parameters. Thus, equivalent circuit parameters are gradually refined step by step. The validity of the proposed method is evaluated by comparing the computed values obtained by the equivalent circuit parameters with the experimental values of the load test.
The Transactions of The Korean Institute of Electrical Engineers
/
v.56
no.6
/
pp.1105-1110
/
2007
This paper describes an equivalent circuit modeling of 4-port connector system. A coupled transmission line was designed and fabricated, mimicking a 4-port connector system, and then S-parameters were measured using 4 port VNA (Vector Network Analyzer). The S-parameters from measurement and from Full-wave simulator coincided quite nice. By using these S parameters, an equivalent circuit parameters for a 4-port system was obtained. The time domain response from the equivalent circuit model matched to the signals, which was measured using TDR(Time Domain Reflectometry) meter. We were also convinced that there should be enough bandwidth to get a meaningful time domain result from Fourier inverse transformation of the S parameters. In addition, we applied the conversion algorithm to the 4-port connector system, which calculates the S-parameters of a 4 port system using the data from a 2-port VNA with the other ports open. Comparison of the two data, one from measurement and the other one from the conversion algorithm, was made in this manuscript.
A new frequency-variant equivalent circuit model of power/ground plane is presented. The equivalent circuit is modeled with grid cells. The circuit parameters of each cell were extracted by using Fasthenry. To verify the developed circuit model, its s-parameters are compared with the measured s-parameters 〔2〕 and the full-wave simulation-based s-parameters. Consequently, it is shown that our frequency-variant equivalent circuit model can accurately predict imperfect ground effects under the high frequency operation of electronic package.
In this paper, a method for an accurate and fast transient analysis, which employs a single slot model for the rotor, is presented. The equivalent circuit parameters are extracted from a combined method of F. E. M and equivalent circuit on 1 slot rotor boundary condition. Two kinds of circuit parameters for each slip are applied to equivalent circuit controlled by variable-voltage variable- frequency. One is the constant parameters at rated speed, and the other is the parameters varying in accordance with slip-frequency. The computer characteristics of the suggested method for four-pole 1.5KW induction motor are compared with those of Equivalent circuit for the transient analysis.
This paper describes the calculation of the equivalent circuit parameters according to the slip in squirrel-cage induction motor. Recently, the induction motor is demanded of the various operation condition. In order to acquire the accurate characteristic for the operation condition of the motor, equivalent circuit parameters have to be calculated accurately. So the equivalent circuit parameters are computed by using the finite element method, the reliable characteristic analysis is carried out by application of the parameter to the equivalent circuit analysis. From the analysis result using this combined equivalent circuit and finite element method is compared with the experimental results by a detailed equivalent circuit, the validity of the method is proved.
An effective estimation method of equivalent circuit parameters of three-phase induction motor by using FEM is presented in this paper. Arbitrary three torque-speed points at asynchronous speed on the torque-speed curve are required by using time-stepping FEM, then the equivalent circuit parameters of IM can be calculated rapidly with presented method. After obtaining the equivalent circuit parameters, the general analysis method based on equivalent circuit can be used to get entire torque-speed curve very quickly. Although the purely numerical method such as FEM also can estimate torque-speed curve directly and accurately, however, usually this process is time consuming.
This paper describes a parameter extraction method for HBT(Heterojunction Bipolar Transistor) equivalent circuit model without measurements of special test structures or numerical optimizations. Instead, all equivalent circuit parameters are calculated analytically from small-signal S-parameters measured under different bias conditions. These values being extracted from the cutoff mode can be used to extract intrinsic parameters at the active mode. This method yields a deviation of about 1.3 % between the measured and modeled S-parameters.
The Transactions of the Korean Institute of Electrical Engineers B
/
v.49
no.11
/
pp.720-728
/
2000
This paper describes the calculation of the equivalent circuit parameters and the characteristic analysis of a capacitor-run type single-phase induction motor by means of the finite element method in coupled with the conventional equivalent circuit model. The circuit parameters of the stator are calculated form the lumped parameter and the slot leakage reactance of the rotor with the closed slot can be obtained by the use of slot pitch boundary condition. From the analysis result this combined equivalent circuit and finite element method which is used slot pitch boundary condition is compared with the experimental results, the validity of the method is proved.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.