• Title/Summary/Keyword: Equipment Reinforcement

Search Result 123, Processing Time 0.026 seconds

Structural Optimization of Industrial Safety Helmet According to Frame Shape using Engineering Plastic (엔지니어링 플라스틱 소재별 보강뿔대 형상에 따른 산업용 안전모의 구조 최적화)

  • Park, Man-Ho;Lee, Yeo-Wool;Lee, Yong-Moon;Park, Jae-Ha;Kang, Myungchang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.41-48
    • /
    • 2019
  • The industrial safety helmets are personal protective equipment (PPE), used to protect the head against falls from a height. This study indicated the necessity of wearing a safety helmet while working at heights below 4 m, through analysis of fall accidents occurring in the industrial field. The stress, displacement, and strain of the safety helmet shell structure have been analyzed using the finite element method with various thicknesses, engineering plastics, and designs. It was preferred that the safety helmet shell structure had a reinforcement frame of uniform thickness in terms of increased impact strength and strain energy absorption rate. The thickness can be reduced to lighten the total weight for workers wearing safety helmets.

Improvement Plan for Safety Management System related to Kids Cafe

  • Jeong, Myeong-jin;Lee, Myeonggu
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.183-188
    • /
    • 2020
  • As the number of kids cafes, one of the children's playgrounds, is increasing rapidly, safety accidents in the kids cafe are also increasing rapidly. The facility is also increasing as the need increases, but it is spreading without ensuring safety. In particular, the Ministry of Public Administration and Security for children's play facilities in the kids cafe, and the Ministry of Culture, Sports and Tourism for organic organizations are divided into different departments, so it is not easy for local governments to manage and supervise the actual business, and there are safety blind spots. Kids cafes have changed rapidly according to needs of children and guardians who are users, and there are many problems associated with them. Therefore, we identified problems that may arise due to insufficient safety management systems for kids cafes, investigated the safety management related to kids cafes in advanced countries, and compared and analysed them with domestic systems. As a result of the research, we proposed a safety management reinforcement system, and we hope to contribute to the reduction and prevention of kids café safety accidents.

Analysis and Survey on Occupational Safety and Health Management Expenses in the Construction Industry (건설업 산업안전보건관리비 사용 실태조사 및 분석)

  • Sung-Yun Kang;Oh-Se Wook;Kim-Chang Won;Kihyo Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.113-120
    • /
    • 2023
  • Occupational safety and health management expenses in the construction industry are statutory and separately included in the cost statement to prevent occupational accidents and health problems. The expenses are determined by multiplying the standard amount by the rate decided according to construction types and scales. However, the current expense appropriation method does not properly reflect the recent changes in the construction industry such as industry size, industry diversification, and social atmosphere about safety reinforcement. This study surveyed 1579 questionnaires in total and analyzed expense execution rate and proportion of each expense category. The expense execution rate was relative higher in complex construction (e.g., heavy construction = 126%, civil engineering = 125%) and long-period project (equal to or over 48 months construction = 133%) compared to general construction (98~116%) and short-period project (less than 48 months construction = 115%). The proportion of spending expenses was higher in the category of safety manager labor costs (25~52%), safety facility costs (22~40%), and personal protective equipment costs (10~25%). The analysis results of the study can be utilized in revising the standard expense appropriation method by reflecting the current usages of the occupational safety and health management expenses in the construction industry.

Comparative Analysis of Bearing Capacity by Road Pavement Method Using Geocell (Geocell을 활용한 도로포장 공법별 지지력 비교 분석)

  • Suhyung Lee;Hyunwoo Jin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.19-29
    • /
    • 2023
  • The main problem with roads is that cracks and settlement occur over time due to loads acting from the surface layer. One way to solve this problem is to use Geocell. Geocell can be used for structural reinforcement for erosion prevention, ground stabilization on flat and steep slopes, load bearing, and ground preservation. In this study, analyzed road pavement application cases using Geocell and purpose of this study is to analyze the bearing capacity of a road paving method including Geocell using field tests and LFWD(Light Falling Weight Deflectometer) equipment. In addition, the bearing capacity was compared and analyzed with the existing traditional road pavement method.

Reinforcement of mechanical properties in unsaturated polyester resin with nanosheet

  • Vahid Zarei
    • Advances in nano research
    • /
    • v.16 no.1
    • /
    • pp.81-90
    • /
    • 2024
  • In the oil and gas industry, composite materials should exhibit high flexibility and strength for offshore structures. Therefore, weak points in the composites should be improved, such as brittleness, moisture penetration, and diffusion of detrimental ions into nanometric pores. This study aimed to increase the strength, flexibility, and plugging of nanopores using single-layer graphene oxide (SGO) nanosheets. Therefore, SGO is added to unsaturated polyester resin at concentrations of 0.015 and 0.15 % with Normal Methyl Pyrrolidone (NMP) as a solvent for the formation of Nanographene Oxide Reinforced Polymer (NGORP). The mechanical properties of the prepared samples were tested using tensile testing (ASTM-D 638). It has been shown that incorporating SGO, approximately 0.015%, into the base resin resulted in enhanced properties such as rupture resistance forces increased by 745.61 N, applied stress tolerances increased by 4.1 MPa, longitude increased to 1.58 mm, elongation increased by about 2.38%, and rupture energy increased by about 204.51 J. Despite the decrease in tensile force strength properties in the manufactured nanocomposite with 0.15% SGO, it has exclusive flexibility properties such as a high required energy level for rupture of 5,576 times and a formability of 40% more than the base sample. It would be best to use NGORP manufactured from 0.015% nanosheets with exclusive properties rather than base samples for constructing parts and equipment, such as rebars, composite sheets, and transmission pipes, on offshore platforms.

Research on Importance-Performance Analysis of Smart Construction Safety Management System (스마트 건설안전관리시스템의 중요도-성과도 분석 연구)

  • Jong-Yil Park;Chang-Hee Yun
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.43-53
    • /
    • 2024
  • This study analyzes the importance-performance analysis (IPA) of the 10 dimensions of the smart construction safety management system, and analyzes which dimensions are important and which dimensions are performing to determine key improvement tasks, incremental improvement tasks, Maintenance and reinforcement tasks and continuous maintenance tasks were derived. Among the 10 dimensions of the smart construction safety management system, the dimensions that are recognized as important by all field managers and field workers and have high performance are the automatic risk displacement measurement system, smart environmental sensor system, and heavy equipment seizure prevention system. However, areas that were perceived as having high importance but low performance were worker location tracking systems, smart safety helmet chin muscles, and smart safety ring fastening. Among the smart construction safety management systems perceived by field managers, areas for key improvement with high importance and low performance included worker location tracking system and smart safety ring fastening. Among the smart construction safety management systems perceived by field workers, the area for key improvement with high importance and low performance was the automatic risk displacement measurement system.

A study on the improvement of antenna switching module structure of ground based ES equipment (지상용 ES장비의 안테나전환기 구조 개선에 관한 연구)

  • Kim, Seung-Woo;Lee, Kang-Ho;Chin, Hui-cheol;Choi, Jae-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.151-159
    • /
    • 2017
  • The aspect of modern warfare is gradually changing to a network of warfare, and its central information electronic warfare is evolving every day. Recently, domestic equipment of electronic warfare, which have succeeded in domestic localization, are strongly influenced by the nature of the environment. Therefore, the structural reliability of the antenna switching module that connects the mast and antenna of the ES equipment is the most important. This study proposed a structure that has an improved structure of antenna switching module by currently analyzing the structure of the antenna switching module and the environmental influence. By modifying the structure of the antenna switching module welding method and part of the reinforcement block, the structure was improved and the validity of the improved antenna switching module was simulated using a load test. The simulation showed that the safety factors of antenna switching module welding point and reinforced block part was enhanced 5.3 and 1.5 times compared to the existing values. These values were verified by load (181kg) test results, which was each 3.7Mpa and 64.4Mpa. The load test results were similar to the simulation results and load supporting capacity of the proposed antenna switching module was enhanced.

A Study on Cognition about 119 Rescue·First Aid Team - Gwangju Area College Student as the Central Figure - (119구조·구급대에 대한 인식도 조사 연구 - 광주지역 보건계열과 비보건계열 대학생을 중심으로 -)

  • Kim, Kab-Sun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.141-152
    • /
    • 2002
  • The purpose of this study is to provide the basic materials for searching the way of improvement to heighten the emergency medical welfare level by one step further. To achieve this purpose, the subjects of this study were selected 452 college students in Gwangju, using a random sampling method. The statistical analysis methods utilized for analyzing the collected data are frequency analysis, $x^2$ test. The conclusions obtained from these analyses are as following ; 1. In question about necessary optimum number of persons for rescue first aid activity, health and non-health major college students responded by 39.2%, 45.3% respectively that rescue team 15 people, first aid team 3 people is most suitable. But there was no significant difference in major department(p<0.05). 2. In question about security of the public health doctor and the emergency medical technician, all health and non-health major college students are recognizing necessity urgently, but there was no significant difference in major department(p<0.05). 3. In question about 119 rescue first aid team member applying for an examination qualification grant to the department of EMT's graduate, all health and non-health major college students were highest by 52.9%, 52.4% respectively in "necessity" item. But there was no significant difference in major department(p<0.05). 4. Because rescue first aid equipment level appears higher than 41.7% in non-health major college student's case by 54.2% in health major college student's case, health major college students are recognizing that equipment level should be supplemented more but there was no significant difference in major department(p<0.05). 5. In question about equipment supplement, all health and non-health major college students appeared highest by 64.8%, 69.3% in accident type different special equipment. But there was no significant difference in major department(p<0.05). 6. In question about rescue ambulance car size, we could know being thinking that health and non-health major college student each 61.2%, 56.5% is small and narrow that large size of the rescue ambulance amount need. But there was no significant difference in major department(p<0.05). 7. In question about patient's state is worsened, because rescue first aid equipment is inferior, health major college student responded sometimes 55.1%, many 29.5%. very many by 11.5%, while non-health major college student responded 65.8%, 23.1%, 4.0% respectively. There was significant difference in major department(p<0.05). 8. In question about emergency patient must utilize for 119 rescue ambulance car, all health and non-health major college students appeared highest by 38.8%, 41.3% in "not so" item. In question about rescue first aid team's first-aid treatment ability improves more, all health and non-health major college students appeared highest by 58.1% and 58.7% respectively in "improve" item. In question about "119 rescue ambulance car must go more rapidly than now", all health and non-health major college students are recognizing that should be quicker by 58.1%, 60.9% respectively. When called to 119 all health and non-health major college students responded highest by 55.5%, 53.3% respectively that we must receive first-aid treatment direction from a doctor. In question about "119 rescue ambulance car must be made the pay system", all health and non-health major college students responded 74%, 80% respectively in "not so" item. There was significant difference in major department(p<0.05). In conclusions, In oder to provide superior rescue first aid service to people, a public health doctor should be placed in the situation room inside the fire station so that the doctor could instruct the proper emergency treatment suitable for each situation to the rescue first aid team. Also, national education about a first-aid treatment that do to all people is necessarily necessary in emergency delivery system and this should be spread extensively through school education and broadcasting medium and education should be gone side by side, and see that will can save emergency patients' life which is more when these education consists continuously fixed period for public institution of policeman, fire officer etc. specially. And for reinforcement of patient transfer system, public organization must procure special ambulance car so that emergency patient receive first aid treatment while transfer.

  • PDF

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.

Design Improvements for Preventing Crack of Equipment Mounting Structure in Rotary Wing Aircraft (회전익 항공기의 장비 장착 지지 구조물의 균열 방지를 위한 설계 개선)

  • Bang, Daehan;Lee, Sook;Lee, Sanghoon;Choi, Sangmin
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.1
    • /
    • pp.28-35
    • /
    • 2020
  • This paper presents the design improvements made for the crack which is in the mounting structure of the mechanical structure of rotary wing aircraft. The doubler added to the mounting structure of rotary wing aircraft was designed and manufactured based on the load at the development stage, and a crack was found in the surface of doubler at a certain point during the operation of the aircraft. To identify the cause of the crack, the initial deformation of the structure, which may occur as a result of fastening condition, was considered and the dynamic analysis of the natural frequency of the structure comparing to the blade passing frequency of the aircraft were additionally reviewed. As a result of this study, a shim was added to remove the physical gap of the fastening area, and a doubler with thickened reinforcement was installed. The increase of structural strength is shown by reviewing the results of dynamic analysis for the structural verification of the improved design, and the fatigue evaluation complied to the requirement of the aircraft lifetime.