• Title/Summary/Keyword: Environmental standard

Search Result 4,689, Processing Time 0.032 seconds

TCE Exposure Assessment of Cleaning Workers (세척공정의 트리클로로에틸렌 TWA 및 STEL 평가 사례)

  • Hyun Soo Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.3-5
    • /
    • 2023
  • Objective: This study introduces exposure concentrations of time-weighted average standard (TWA) evaluation and short-time exposure standard (STEL) evaluation for trichloroethylene in the cleaning process. Methods: Trichloroethylene measurement was conducted according to the KOSHA Guide (A-24-2019) method. It was carried out twice. Results: As a result of the first measurement, TWA concentration exceeded 4 times the exposure standard and STEL concentration exceeded 16 times, but the inaccuracy and breakthrough of the collection time could not be considered, so the second measurement was conducted. The second measurement result was lower than the first measurement result, but exceeded the exposure standards (TWA, STEL). Conclusions: We were able to confirm that the exposure level of workers in the cleaning process using trichloroethylene exceeded the exposure standard. And it is also considered necessary to grasp the approximate concentration using a detector tube in the preliminary survey.

A Comparative Study of Standard Methods for Assessing Ecotoxicity of Endocrine Disrupting Chemicals (내분비계장애물질의 생태독성평가를 위한 표준시험법 비교연구)

  • Kwak, Jin Il;Cui, Rongxue;Moon, Jongmin;Kim, Dokyung;An, Youn-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.132-139
    • /
    • 2017
  • Endocrine disrupting chemicals (EDCs) interfere with endocrine system in organisms, and have different mode of actions compared to conventional chemicals. Therefore, EDCs specific ecotoxicity tests and assessments have been globally developed by some organizations such as OECD, ASTM, and USEPA. In Korea, researches on EDCs and monitoring of EDCs in domestic environments were also continued. However, Korean ecotoxicity test guidelines for EDCs are not suggested till date. The purpose of this study is to review and analyze international ecotoxicity test guidelines for EDCs and the compare ecotoxicity methods and toxicity endpoints among standard test guidelines. We found that there are very limited EDCs specific soil ecotoxicity test guidelines (only in ASTM) compared to aquatic ecotoxicity test guidelines. Currently, fish, amphibian, waterflea, copepoda, earthworm, white worm, springtail, nematode, mite, and midge are suggested as standard ecotoxicity test species for EDCs. Reproduction, hormones, growth, vitellogenin, sex retio and development were proposed as endpoints for EDCs ecotoxicity. This study provided the comparison of EDCs specific ecotoxicity methods and endpoints between standard test guidelines, and suggested the further research to develop the method for assesseing ecotoxicity of EDCs.

A Case Study of Landfarming Design Procedures for Remediation of Oil-contaminated Site (유류오염지역 정화를 위한 토양경작법 설계 표준화방안)

  • Cho, Chang-Hwan;Park, Jeong-Gu;Park, Min-Gyu;Jeong, Seung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.9
    • /
    • pp.659-666
    • /
    • 2014
  • The purpose of this study was to suggest a standard design procedure of landfarming for clean-up of oil-contaminated soils. The standard design procedure consisted of four main phases; soil characterization, determination of contaminated soil volume, determination of nutrient and microbial doses, and estimation of the total remedial period. This study selected standard design parameter values or ranges among various forms used in environmental engineer communities. Those were determination procedures for the contaminated soil volume, the initial contamination concentration and nutrient doses. The suggested standard design procedure were applied for a landfarm design for remediation of a real oil-contaminated site. Soil texture of the site was classified as sandy clay loam and sandy loam. Total nitrogen and total phosphorus were estimated to be 57.01 mg/kg and 83.40 mg/kg, respectively. Also the viable bacterial numbers was assessed to be $1.78{\times}10^4CFU/g$ dry soil. The amount of TPH contaminated soil was estimated to be $4,092m^3$. With the application of remedial factors, it was estimated that the contaminated soil could be treated through 9 batches with a duration of 315 days for a landfarming unit of $15m{\times}40m{\times}1m$. The amount of liquid microorganisms and fertilizers were recommended to be 4,025L and 4,641kg, respectively.

A Sanitary Survey on the Clean Water by Domestic Purifier (가정용 정수기의 수질에 대한 위생학적 조사 소견)

  • 채용곤
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.65-72
    • /
    • 1990
  • To study on the water quality of domestic purifier, twenty four samples of clean water by purifier and the raw water(tap water) were tested for biological and physico-chemical examination and were checked for style of purification and the period elapsed after changing of purification medium. The results were as follows; Biological and physico-chemical findings of raw water were not exceeded standard values. Average number of general bacteria,2.coli and pH in clean water were significantly higher than that of raw water(respectively, p<0.01), but mean contents of turbidity, chloride, nitrate and iron in clean water were significantly lower than that of raw water(respectively, p<0.01). In general count of bacteria and E.coli, a half of the clean water of ceramic filter and roverse osmosis style were exceeded standard values for drinking water. All of the pH of the ion exchange style clean water were exceeded standard values. But other findings were within standard values. In average bacterial counts and physico-chemical findings of clean water by purification style of purifier, clean water of ion exchange style purifier were lowest number of general bacteria and not detected in 2. coli. But other items were highest. The longer period elapsed after changing of purification medium were the higher contents of biological and physico-chemical findings of clean water.

  • PDF

Research on the well-being-centric green building certification - Focused on AHP Analysis of Expert Survey in order to introduce well-being criteria - (웰빙 중심 친환경 건축인증을 위한 연구 - 웰빙항목 도입을 위한 전문가 AHP 분석을 중심으로 -)

  • Nam, Hye-Ryeong;Lee, Byung-Yun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.29-38
    • /
    • 2016
  • Purpose: This study is conducted to contribute to the improvement of Green Standard for Energy and Environmental Design(G-SEED) from the existing energy physical efficiency-centric system to the well-being-centric green building certification system. Method: In order to modify existing G-SEED Certification, three phases of research have been conducted; 1) identification of needs of well-being-centric environment-friendly construction certification system, 2) comparison of domestic certification system with WELL Building standard(WELL) which focuses on human health and promotion of wellness and 3) AHP analysis to sort out the supplement items from WELL. Result: We proposed four alternatives which should be preferentially introduced to the existing domestic certification system; addition of independent 'well-being' section(field) in G-SEED, insertion of 'well-being' indicators in each relevant section of G-SEED, addition of 'well-being' indicators in 'Innovative Design(ID)' of G-SEED and independent score systems for 25 items in a high priority.

Recent Development of Drinking Water Quality Standard and its Application (음용수질 기준과 관리방안)

  • 권숙표
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.83-94
    • /
    • 1992
  • Recently water demand is increasing as the industry prospers. The increase of water demand is followed by the increase of wastewater discharge which pollutes rivers and ground water extensively. These rivers, reservoirs and ground water are sources for drinking water and their contamination affects the quality of water supply and other potable water. In Korea there are 776 water treatment plants which supply drinking water from main rivers or reservoirs. Rivers are the biggest water source for drinking water is being contaminated, the innovation of treatment process is needed. The construction and operation of water supply facilities is under the control of the Ministry of Construction and the water supply offices of cities and provinces. However, drinking water quality is under the control of the bureau of sanitation in the Ministry of Health and Social Affairs. There are 33 items in drinking water quality standards of Korea. Trihalomethanes, Selenium, Diazinone and other three of pesticides have been included lately, The Ministry of Health and Social Affairs is planning to enhance. the level of $VOC_S$(Vola-tile Organic Compounds) standard. Drinking water quality standard is the goal to protect the quality of supply water and ground water. In order to protect the source water from domestic or industrial water, technological improvement and adequate investment should be urgently made. The ultimate goal of drinking water quality is safety and health of consumers. The more stringent the standard are, the better the water quality will be. As the drinking water quality standards become more stringent this year, various and positive solutions by the authorities concerned must be prepared.

  • PDF

The Determination of Optimal Steel Pipe Wall Thickness Considering Ground Condition (지반 조건을 고려한 최적강관두께의 결정)

  • Park, Jaesung;Oh, Bungdong;Lee, Hojin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.11-15
    • /
    • 2008
  • By considering manufacture and economic factor, the steel pipes have been employed for water supply pipeline with large diameter. The standard to decide a thickness of pipe was provided by the waterworks standard (Ministry of Construction & Transportation, 1992) in South Korea. However, there was no the systematic standard to confirm a thickness of pipe in it. Thus, it should be able to apply to unsuitable the Stewart formula for the buried pipe to design for an optimum thickness of pipe. In order to meet revised the waterworks standard (The Ministry of Environment, 1997), it has been considered both the ground condition and all of the stresses to compute a thickness of pipe. As a results, a method is suggested to determine thickness of pipe after comparing and validating the obtained results with the established results from the Stewart formula.

  • PDF

Comparisons on Specifications of Mating Electrical Connectors for NASA Standard Initiators (나사 표준 착화기 (NASA Standard Initiators) 연결 전기 커넥터의 규격 비교)

  • Kim, In Sung;Jeong, Eun Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.418-422
    • /
    • 2017
  • Based on published materials, we compared specifications of mating electrical connectors for the NASA Standard Initiators NSI-1,2,3 with each other after the initiator specifications summary. The mating connector specifications for NSI-1,2 are MSFC-40M38298 and MIL-DTL-26482, series1 while for NSI-3 is MIL-DTL-38999, series3. The MIL-DTL-38999, series3 has the highest overall environmental resistance performance. MSFC-40M38298 is the next and MIL-DTL-26482, series1 follows. In particular, if initiators be used under severe shock and vibration environments, the MIL-DTL-38999, series3 should be applied.

  • PDF

A Study on Worker Exposure to Asbestos Fibers During Automobile Maintenance (自動車整備業 從事者의 石綿粉塵 暴露에 관한 조사연구)

  • Shin, Yong-Chul;Paik, Nam-Won
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.1
    • /
    • pp.19-32
    • /
    • 1989
  • This study was performed to evaluate the worker exposure to asbestos fibers in automobile repair shop and brake lining store from August 11 to October 21, 1988. In addition, the exposure of general population near the brake lining store was also evaluated. Results of this study were as follows. 1. Worker exposure level to asbestos fibers in automobile repair shop was 0.1 fibers/cc, well below the Korean standard of 2 fibers/cc, and a half of the U.S. standard of 0.2 fibers/cc. 2. Average worker exposure level to asbestos fibers in brake lining store was 0.35 fibers/cc, which was within the Korean standard of 2 fibers/cc, but exceeded the U.S. standard of 0.2 fibers/cc. 3. Worker exposure levels during the removal of brake dust with the compressed air blowing and the dry brushing were approximately 4 fibers/cc and 0.2 fibers/cc, respectively. During grinding of brake linings with sand paper, asbestos exposure level was 0.3 fibers/cc. 4. Ambient asbestos concentrations outside the brake lining store were 0.1 fibers/cc at the distance of 3-4 m, and 0.01 fibers/cc at the distance of 30 m.

  • PDF

Application of BASIN 4.0 and WinHSPF to a Small Stream in Total Water Pollution Load Management Area and Calibration of Model Parameter using Genetic Algorithm (오염총량관리지역내 소하천에 대한 BASINS 4.0 및 WinHSPF의 적용과 유전알고리즘을 이용한 매개변수의 보정)

  • Cho, Jae-Heon;Yun, Seoung-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.1
    • /
    • pp.161-169
    • /
    • 2012
  • Recently various attempts have been made to apply HSPF model to calculate runoff and diffuse pollution loads of stream and reservoir watersheds. Because the role of standard flow is very important in the water quality modelling of Total Water Pollution Load Management, HSPF was used as a means of estimating standard flow. In this study, BASINS 4.0 and WinHSPF was applied to the Gomakwoncheon watershed, genetic algorithm(GA) and influence coefficient algorithm were used to calibrate the runoff parameters of the WinHSPF. The objective function is the sum of the squares of the normalized residuals of the observed and calculated flow and it is optimized using GA. Estimates of the optimum runoff parameters are made at each iteration of the influence coefficient algorithm. The calibration results showed a relatively good correspondence between the observed and the calculated values. The standard flow(Q275) of the Gomakwoncheon watershed was estimated using the ten years of weather data.