A Evaluation of Standard Support Pattern for Two-Arch Road Tunnel (2-Arch 도로터널에 적용된 표준지보패턴의 적정성 검토)

  • Chun, Byungsik;Choi, Kwangbo;Kim, Hyeyang;Yoo, Junhee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.7
    • /
    • pp.25-35
    • /
    • 2008
  • In domestic cases, the standard support pattern of 2-lanes road tunnels is presented because construction experience and high degree various data was abundant. But, it is not desirable to apply standard for 2-Arch tunnels that the precedent and measuring data is insufficient existing support pattern blasting plan and interpretation of separate way concerning specific terrain and rock quality. In this study, behavior according to load distribution ratio and Unsymmetrical Pressure about standard support pattern which is applied in design and construction of 2-arch tunnels was analysed and the examination of blasting vibration has influence on the center wall is conducted as a consequence reasonableness of support whether or not with presumed support pressure and ground reaction curve method. In result appropriateness of standard support pattern, support quantity is proper but considers specific terrain and rock quality condition when design and construction of further step 2-arch tunnel standard support pattern must be decided by considering terrains, soil properties and construction condition of the objective tunnel.

  • PDF

A Study on the Damping Correction Factors for the Korean Standard Design Spectrum (한국 표준설계스펙트럼의 감쇠보정계수에 대한 연구)

  • Heo, Tae Min;Kim, Jung Han;Lee, Jin Ho;Kim, Jae Kwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.1-14
    • /
    • 2018
  • In this study, we develop and propose damping correction factors for the Korean standard design spectra. The newly proposed Korean standard design spectra has been given only for 5% damping ratio. But in practice, engineers need design spectra for damping values other than 5%. To obtain design spectra for various damping values from the standard spectra, damping correction factors are derived. These factors modify the shape of design spectra in accordance with the damping ratio. Response spectra for various damping values are calculated from the earthquake records that had been used to calculate standard design spectra. They consist of 55 records from 18 earthquakes occurred in overseas intraplate regions and Korea. The regressed spectra for the damping values ranging from 0.5% to 50 % are compared with standard spectra at three regions acceleration, velocity and displacement sensitive regions. The regression analysis of these data rendered formula for damping correction factors. Finally, a single formula for damping correction factors is recommended that is valid for both horizontal and vertical design spectra and that is applicable to the entire range of periods. One thing to note that recommended damping correction factors is valid for the design spectrum of the rock grounds because the design spectra was developed based on the earthquake records of the rock ground.

A Study on Improvement of Barrier Free Door Standard (Barrier Free 출입문 규격기준 개선에 관한 연구)

  • Kim, In-Bae;Kim, Won-pil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.7-15
    • /
    • 2017
  • Purpose: The Korean government has implemented a Barrier Free Certification System since 2008 to create a secure and convenient environment for the socially disadvantaged. The drastic increase in the number of BF-certification facilities is expected due to the revision of the system and increasing the number of certification institutions. An analysis of individual evaluation items needs to be made for the BF-Certification with public confidence. Method: Korean standard, International Standard(ISO/FDIS 21542, 2011), German Standard(DIN 18040-1, 2010), Austrian Standard(${\ddot{O}}NORM$ B 1600, 2017) and Swiss Standard(Norm SIA 500 / SN 521 500, 2009) were investigated and analyzed. A comprehensive improvement plan is proposed by comparing details of the aforementioned standards and the evaluation items of BF-Certification. Results: Many problems arise in applying existing Barrier-free standards due to changes in population structure, environmental change and the use of powered wheelchairs. International standards are being improved to solve these problems. The korean standards also require improving of the Barrier Free Law and Certification System, which reflect these trends. In korean cases, standards such as the size of the doors (width and height), the Unobstructed Manoeuvring Space and Clear Space at the Latch side of the Door are required to improve standards in accordance with international standards. In addition, the expression of laws and evaluation items of BF-Certification should be clearly defined. And the application of visual contrast standards for the enhancement of perceptions presented in international standards should be considered. Implication: Barrier Free related legal standards and evaluation items of BF-Certification that are used in Korea are required to be revised in consideration of social and environmental changes. Comprehensive improvements should be made through detailed review.

A Study on Standard Procedure of Road Traffic Noise Map (도로교통 소음지도의 표준 작성절차 연구)

  • Jung, Woo-Hong;Park, In-Sun;Kim, Ji-Yoon;Park, Sang-Kyu;Kang, Dae-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.613-617
    • /
    • 2007
  • Noise maps of a city in Korea have been made using commercial noise map softwares by measuring the basic data in the city. The result in this study will be used to evaluate the environmental impact of noise from various noise sources and to implement the Korean noise map standard.

  • PDF

Reliability Prediction using Telcordia SR-332 in Electric Home Appliance (Telcordia SR-332를 이용한 가전제품 신뢰도 예측)

  • Lee Duck-Kyu
    • Journal of Applied Reliability
    • /
    • v.5 no.4
    • /
    • pp.427-438
    • /
    • 2005
  • This paper is concerned with the problem in predicting the reliability of an LCD product, Product reliability calculation methods classify accelerated life test (ALT) and using the reliability standard as MIL-HDBK-217F and Telcordia SR-332. The reliability standard can calculate estimating value more quickly than accelerated life test. The system MTBF was calculated in accordance of Telcordia SR-332 standard which includes directions of part electronic measurement, temperature rise and environmental test data. This research is intended to obtain the useful information for each electric design step to save time and cost.

  • PDF

Methanol fixation for scanning electron microscopy of plants

  • Ki Woo Kim
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.10.1-10.6
    • /
    • 2020
  • Plant specimens for scanning electron microscopy (SEM) are commonly treated using standard protocols. Conventional fixatives consist of toxic chemicals such as glutaraldehyde, paraformaldehyde, and osmium tetroxide. In 1996, methanol fixation was reported as a rapid alternative to the standard protocols. If specimens are immersed in methanol for 30 s or longer and critical-point dried, they appear to be comparable in preservation quality to those treated with the chemical fixatives. A modified version that consists of methanol fixation and ethanol dehydration was effective at preserving the tissue morphology and dimensions. These solvent-based fixation and dehydration protocols are regarded as rapid and simple alternatives to standard protocols for SEM of plants.

A Study on the Characteristics of Surface Ozone Concentration at Dongsamdong, Pusan (부산 동삼동 지역의 지표오존농도 특성 연구)

  • Jeon, Byung Il
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.2
    • /
    • pp.21-29
    • /
    • 1999
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone and meteorological data of 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was highest in Spring(35.4ppb) and lowest in Winter(22.2ppb). Relative standard deviation indicating clearness of observation site was 0.42 that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong showed maximum at 15~16LST and minimum 07~08LST that typical pattern of ozone concentration. In ozone episode period(May 18~23, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface.

  • PDF

GUI Environmental Controller Design with USB IF (USB IF를 이용한 GUI환경의 제어기 개발)

  • Sun-Hag Hong
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.4
    • /
    • pp.449-454
    • /
    • 2003
  • In this paper, GU environmental controller is implemented with USB(Universal serial bus) IF(interface). Especially, the performance examination of ultrasound diagnostic device which connects external USB port with front panel is automatically inspected by VC++ examination program. The test program minimizes the operation of inspector with making the examined result audible or visible, and maximizes the productivity of custom device. The GUI environmental controller controls a standard keyboard, a track ball with dedicated buttons to emulate a standard two-button mouse, switches, rotary encoders, an analog potentiometer group, two alpha-numeric displays. and a touch screen; all of which generate events for the host.

  • PDF

A Study on an Environmental Test Sequence for Electrical Units on Aircraft (항공기 전장품의 환경시험순서에 관한 연구)

  • Yang, Jung Ho;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.14 no.2
    • /
    • pp.114-121
    • /
    • 2014
  • An environmental test has been performed in order to improve the lifetime and reliability of the electrical units on aircraft. However, faults occurring in the field of aircraft have been difficult to predict and prevent, and new concepts for reliability testing are desired. Therefore, a composite reliability test sequence was proposed in the conventional studies. This study introduces test sequence guidelines based on relevant principles and considerations for electronic testing according to International Standard IEC-60068-1 and the United States Military Standard MIL-STD-810G. In addition, we analyze possible causes of failure using two-step QFD based on aircraft operation scenarios. Finally, the proposed test sequence can reproduce various and realistic failure modes for electrical units on aircraft.