A Proposal of Life Cycle CO2 Assessment Techniques for Building in Construction Stage by BIM LOD (건설단계 BIM을 이용한 건축물의 전 과정 CO2 평가 기법 제안에 관한 연구)

  • Bang, Jun-Sik;Tae, Sung-Ho;Roh, Seung-Jun;Keum, Won-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.53-54
    • /
    • 2012
  • This study is aimed at utilizing LCA processor with BIM LOD, eliciting the problems of the existing environmental assessment by constructing the database for environmental values of green buildings. For these objects, environmental load database of BIM construction material and evaluation process are presented, after matching BIM family based environmental load database which is available during evaluation stage, input-output tables and Korea LCI database to standard item code of public procurement service. It is a important factor in environmental assessment of building to develop database unit of standard item code for BIM and construction material. Thus, the results of this study are expected to provide basic data for improving effectiveness of construction through BIM based environmental load evaluation database. Furthermore, the provided environmental load database unit for construction material is considered to be available as basic information for BIM study by suggesting a processor connecting BIM with LCA and along with this, continuous examination on the connection process is needed.

  • PDF

A Study on the Methods for Usage of Environmental Indexes in Management by Objectives (목표관리에서 환경지표의 활용방법에 관한 연구)

  • Lim, Mann-Taek;Joo, Seung-Ho;Yoon, Kyung-Sup;Kwon, Chang-Yong
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.3
    • /
    • pp.199-208
    • /
    • 2011
  • Environment standards can be used as a foundation of environment administration (specific expression of political goals or quantitative evaluation standards of political effects). When environment adminstration improves severe air or water pollution rapidly, the environment standard can work effectively to show the goals specifically and clearly. The environment index which is designed to evaluate environment systems, should be established to express the environment system generally. To realize sustainable development, the sustainable indexes usually consisting of these three areas in that harmony of environment, economy and society are required. In this research, sustainable environmental indicators to understand the characteristics and to compare likes theme of environmental conditions in international and national level indicators, regional environmental management plan to promote the management by objectives are to provide the basic data. It is desirable for the environmental policies to work harmoniously with direct control, use of economic means and voluntary methods. Regarding the evaluation of environmental index, the action results of civilian's or individual's activities are needed to be reflected into the evaluation.

Dynamic Thermal Rating of Transmission Line Based on Environmental Parameter Estimation

  • Sun, Zidan;Yan, Zhijie;Liang, Likai;Wei, Ran;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.386-398
    • /
    • 2019
  • The transmission capacity of transmission lines is affected by environmental parameters such as ambient temperature, wind speed, wind direction and so on. The environmental parameters can be measured by the installed measuring devices. However, it is impossible to install the environmental measuring devices throughout the line, especially considering economic cost of power grid. Taking into account the limited number of measuring devices and the distribution characteristics of environment parameters and transmission lines, this paper first studies the environmental parameter estimating method of inverse distance weighted interpolation and ordinary Kriging interpolation. Dynamic thermal rating of transmission lines based on IEEE standard and CIGRE standard thermal equivalent equation is researched and the key parameters that affect the load capacity of overhead lines is identified. Finally, the distributed thermal rating of transmission line is realized by using the data obtained from China meteorological data network. The cost of the environmental measurement device is reduced, and the accuracy of dynamic rating is improved.

Evaluation and Comparison with Standard 48 hr Acute Bioassay and High Temperature Rapid Toxicity Test for Sewage Toxicity Test (하수의 독성평가를 위한 표준독성시험법과 온도증가 단기독성평가법의 비교 평가)

  • Lee, Sang-Ill;Jun, Byong-Hee;Weon, Seung-Yeon;Kim, Yi-Jung;Kim, Keum-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.191-197
    • /
    • 2005
  • A new method, ToxTemp (TOXcity test based on TEMPerature control) using Ceridaphnia dubia was applied to evaluate the toxicity of insecticide materials and compared with the standard 48 hr acute bioassay. BPMC, diazinon and fenitrothion may cause the inhibition to the biological process in sewage treatment plant and need to detect toxicity within short contact time. The ToxTemp method showed sensitive detection with more shorter contact of 1-1.5 hr time than that of the standard 48 hr acute bioassay. To evaluate toxicity of real wastewater/sewage, the inhibition rate of nitrification and oxygen uptake rate (OUR) using activated sludge, the standard 48hr acute bioassay and ToxTemp method using C. dubia were compared, respectively. On the basis of the inhibition rate of nitrification, the OUR test showed the less sensitive results at the relatively strong toxic sewage. On the other hands, the standard 48hr acute bioassay and ToxTemp method using C. dubia represented the toxicity of each wastewater/sewage with high sensitivity. Even the slightly low (about 1.5%) sensitivity, the ToxTemp method showed the high applicability to the real site of sewage treatment plant.

Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method (실내공기질 공정시험법 중 VOCs 측정방법의 문제점 고찰 및 개선방안에 관한 연구)

  • Ye, Jin;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.586-599
    • /
    • 2014
  • During the last two decades, indoor air quality and volatile organic compounds (VOCs) have been of concern in Korean society due to their nature of potential health impacts. In order to investigate the pollution levels of VOCss in indoor environments, establishment of a solid test method for monitoring the airborne VOCss is essential. In Korea, a method based on adsorbent sampling and GC analysis coupled with thermal desorption was proclaimed as the Korea Standard Method for Indoor Air Quality Test. This study was carried out to examine some inherent problems of the VOCs measurement method. The VOCs method does not describe in detail preparing the standard samples. The standard samples may be prepared by impregnation of either liquid standard solutions or a mixture of standard gases. In this study, we investigated the optimal temperature condition for transferring the liquid standards onto a standard adsorbent tube. As a result, keeping the impregnation temperature at $250^{\circ}C$ will be recommended in regard of the boiling points of multiple target analytes and the thermal stability of the adsorbent. We also demonstrated some problems associated with handling of a syringe used for transferring the standard solutions onto the adsorbent tubes, and a best way to get rid of the syringe problems was suggested. Finally, a number of field works were conducted to evaluate the performance of adsorbent sampling methods. Comparison of different adsorbent tubes, i.e. tube packed with single sorbent (Tenax) and double sorbents (Tenax with Carbotrap), revealed that 30 to 40% differences between the two groups, implying that sampling efficiency is depending on the volatility and the strength of adsorbents. However, duplicate precisions for VOCs sampling with a same type of adsorbent and at same flow rates appeared to be satisfactory to be all within 20%, which is a quality control guideline. Distributed volume precisions were also found to be within a guideline value, 25%, although the precision was in general inferior to the duplicate precision. The Korea indoor VOCs test method should be more refined and improved in many aspects, particularly procedure and instrumentation for preparing the standard samples and specification of quality control assessment.

International Trends of Environmental Specimen Bank and Our Response (환경시료은행의 국제적 동향 및 우리의 대응)

  • Kim, Myung-Jin;Yoo, Byung-Ho;Lee, Suk-Jo;Lee, Jong-Chun;Lee, Chul-Woo
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.4
    • /
    • pp.225-233
    • /
    • 2008
  • An Environmental Specimen Bank (ESB) is an archive for samples that can be used to document and assess the quality of the environment in which we live. An ESB program looks at changes in the concentration of human and environmental specimens over long periods of time through retrospective analysis of archived samples of a particular area collected at regular intervals. The idea of ESB was first proposed by German and American scientists in the early 1970s and has been established since 1979 in Germany, USA, and Japan. Korea plans to establish a National Environmental Specimen Bank (NESB) in 2010. The NESB will be able to assess and improve the quality of analytical measurements as well as to compare the past and current environmental quality as a time capsule. The concept and design for the NESB facility was developed and its Standard Operation Procedures (SOPs) are being developed based on an evaluation of ESBs and SOPs of Germany, USA, and Japan. Environmental specimens proposed for banking are based on typical representatives of every level of the food chain from each type of ecosystem that are widely distributed thus enabling comparisons between different sampling areas. Through retrospective analysis of environmental specimens, the NESB will improve the reliability of environmental monitoring, ecological risk assessment, and health impact assessment.

Improving Strontium Isotope Ratio Analysis Using MC-ICP-MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 스트론튬 동위원소비 분석법 개선)

  • Lee, Sin-Woo;Park, Jaeseon;Park, Hyun-Woo;Hwang, Jong Yeon;Kim, Kumhee;Chung, Hyun-Mi;Choi, Jong-Woo
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.237-242
    • /
    • 2018
  • Strontium (Sr) commonly exists in rock, groundwater, soil, plants, and animals. The Sr isotope ratio offers important information as a tracer on nature because the Sr isotopic composition is not fractionated by any biological process in these ecosystems. Hence, Sr isotope ratio has been used in several studies on tracing the Sr source for contaminated sites and human migration. In this study, we developed a separation method for Sr content, and then improved Sr isotope analysis using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). A powdered rock standard (NIST 2710a) was used to determine the removal of interference elements (Rb and Ca) and the recovery rate of Sr content. The results ranged from 98% to 106%. Additionally, three standard samples (NBS 987, IAPSO and NIST 1486) were analyzed to evaluate the precision and accuracy of the results. The measured $^{87}Sr/^{86}Sr$ ratio for all the samples were consistent with the reported values, within an error. These results indicate that our established Sr separation and Sr isotope measurement methods are reliable and can hence be useful in the fields of environmental and forensic sciences.

Assessment on the Extraction Efficiency of Explosive Compounds in Soil for Improving the Working Draft of International Standard (국제표준(안) 개선을 위한 토양 중 화약물질 추출 효율성 평가)

  • Lee, Goon-Taek;Jung, In-Ho;Kim, Bo-Hyun;Kim, Dong-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.1
    • /
    • pp.42-46
    • /
    • 2012
  • The ISO document of ISO/TC/190/SC3/WG11/N11 is a working draft of international standard (WD) dealing with analytical method for the determination of explosives and related compounds using high performance liquid chromatography. The scope of this WD covers the storage of samples, preparing test portion, extraction and instrumentation. The main purpose of this study was to improve the extraction conditions which were already adopted in the WD. For this purpose, mechanical shaking method could be corresponded up to 18 hours of ultrasonic bath extraction in the WD was tested. Methanol was also tested with the intention of being added as an extracting solvent other than acetonitrile in the WD. According to the results, 16 hours of mechanical shaking method showed statistically the same effectiveness as that of 18 hours of ultrasonic bath extraction. In case of extracting solvent, methanol also showed statistically the same extraction capability as acetonitrile for DNB, TNT, 2-A-DNT and 2,4-DNT. However, the recovery rate of TNB with methanol extraction was 40% higher than that of acetonitrile extraction. Through adding mechanical shaking method into committee draft (cf. the next stage draft of the WD during the process for making international standard), ISO standard of analyzing explosives and related compounds in soil would become more useful in dealing with huge number of field samples in the laboratory. In other aspect, adopting methanol as an alternative extracting solvent would be very effective in the terms of exchangeability with GC-ECD/MS method which is being developed by German experts.

Process Standardization for the Construction of Job-Exposure Matrix Using the Work Environment Measurement Database (작업환경측정 결과 데이터베이스를 활용한 직무노출매트릭스 구축을 위한 공정 표준화)

  • Sangjun Choi;Ju-Hyun Park;Dong-Hee Koh;Donguk Park;Hwan-Cheol Kim;Dae Sung Lim;Yeji Sung;Kyoung Yoon Ko;Ji Seon Lim;Hoekyeong Seo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.78-90
    • /
    • 2023
  • Objectives: The purpose of this study is to standardize the process code of the work environment measurement database (WEMD) for the construction of a job-exposure matrix (JEM). Methods: The standard process code (SPC) was reclassified based on process similarity and drawing upon the code used in the existing K2B. It was supplemented through review by industrial hygiene experts. In addition, an index word database related to SPC was created and used for SPC search. A pilot evaluation project was conducted by experts to evaluate the validity of the newly reclassified standard process code. Results: A total of 70 final SPCs were developed, including 31 processes related to the construction industry. Using the Shiny program, we developed a standard code finder that can be used on the web (https://kscf.shinyapps.io/scf_app/). As a result of the pilot evaluation, it was determined that it was easier to search for standard codes than previous codes, so it was highly utilized. Conclusions: It is expected that JEM construction using industry-process information drawing on WEMD data will be possible using the 70 newly standardized process codes.