• 제목/요약/키워드: Environmental radiation measurement

검색결과 155건 처리시간 0.033초

고에너지 전자선의 흡수선량 측정에 있어서 TLD의 유용성 (Measurement of Absorbed Dose for High Energy Electron using $CaSO_4:Tm$ - PTFE TLD)

  • 박명환;김도성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권1호
    • /
    • pp.97-101
    • /
    • 2000
  • In this study, the highly sensitive $CaSO_4:Tm$-PTFE TLDs has been fabricated for the purpose of measurement of high energy electron. $CaSO_4:Tm$ phosphor powder was mixed with polytetrafluoroethylene(PTFE) powder and moulded in a disk type(diameter 8.5 mm. thickness $90\;mg/cm^2$) by cold pressing. The absorbed dose distribution and ranges for high energy electron were measured by using the $CaSO_4:Tm$-PTFE TLDs. The ranges determined were $R_{100}=14.5mm$, $R_{50}=24.1mm$ and $R_P=31.8mm$, respectively and the beam flatness, the variation of relative dose in 80% of the field size, was 4.5%. The fabricated $CaSO_4:Tm$-PTFE TLDs nay be utilized in radiation dosimetry for personal, absorbed dose and environmental monitoring.

  • PDF

Alpha 입자비적법(粒子飛跡法)에 의(依)한 Radon 측정(測定) (Radon Measurement by Alpha Particle Track Method)

  • 강영호;박장식;김도성
    • Journal of Radiation Protection and Research
    • /
    • 제7권1호
    • /
    • pp.17-22
    • /
    • 1982
  • 지표하에서 방출되는 토양기체중의 라돈농도 측정은 환경방사능, 우라늄탐색, 지진예지 등에 관한 연구에 널리 이용되고 있다. 본 연구에서는 초산 셀룰로우즈(LR115-Type2와 CA80-15, Kodak $Path\'{e}$)와 CR-39의 플라스틱 비적검출기를 부착한 라돈컵을 제작하여 경북일원에서의 토양기체중 라돈농도를 측정하였다. 제작한 라돈컵내에는 일정량의 $CaSO_4$를 건조제로 사용하여 플라스틱 검출기에 미치는 습기의 영향을 감소시켰으며, 라돈컵의 라돈검출 환산인자는 $1tr/cm^2{\cdot}30days=1.2{\times}1.0^{-2}pCi/l$였다. 1981년 1월부터 1982년 2월 사이의 대구에서의 평균 라돈농도는 39.1pCi/l였다. 한편 1981년 8월부터 1982년 2월 사이의 대구, 안강, 경주, 포항, 청하, 안동에서의 평균 라돈농도는 각각 31.8pCi/l, 124.5pCi/l, 127.0pCi/l, 79.1pCi/l, 144.4pCi/l, 70.9pCi/l였으며, 이 결과를 TLD에 의한 환경방사능 측정치와 비교하였다.

  • PDF

원자력 사고후 주민의 이주를 위한 유도개입준위 산정의 실용적 방법론 (A Practical Methodology for Determination of Derived Intervention Levels on Relocation Following a Nuclear Accident)

  • 황원태;김은한;서경석;정효준;한문희;이창우
    • Journal of Radiation Protection and Research
    • /
    • 제29권2호
    • /
    • pp.91-96
    • /
    • 2004
  • 원자력시설의 사고로 인한 방사성물질의 환경 누출후 주민의 이주를 위한 유도개입주위 산정의 실용적 방법론을 지표면 선량율에 근거하여 고안하였다. 이주를 요하는 기간에 따라 잠정 이주와 영주이주로 구분하여 환경특성 변수 값에 따른 유도개입준위의 영향을 고찰하였다. 이주를 위한 유도개입준위는 방사성물질의 지표 침적후 핵종의 유효 제거 반감기, 측정 지연시간 피폭자의 거주특성 등에 따라 뚜렷이 다르게 나타났다. 특히 지표면 선량율이 지수함수 형태가 아닌 멱함수 형태의 감소를 가정하는 경우 측정 지연시간은 유도개입준위 설정에 있어 중요한 요소로 작용한다는 것을 알 수 있다. 핵종의 유효 제거반감기가 길수록 측정 지연시간이 늦을수록 그리고 피폭자가 오염원에 노출되는 시간이 길수록 유도개입준위는 보다 낮은 값을 나타냈다.

The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye

  • Yokoyama, Sumi;Tsujimura, Norio;Hashimoto, Makoto;Yoshitomi, Hiroshi;Kato, Masahiro;Kurosawa, Tadahiro;Tatsuzaki, Hideo;Sekiguchi, Hiroshi;Koguchi, Yasuhiro;Ono, Koji;Akiyoshi, Masahumi;Kunugita, Naoki;Natsuhori, Masahiro;Natsume, Yoshinori;Nabatame, Kuniaki;Kawashima, Tsunenori;Takagi, Shunji;Ohno, Kazuko;Iwai, Satoshi
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.1-7
    • /
    • 2022
  • Background: In Japan, new regulations that revise the dose limit for the lens of the eye (hereafter the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulation Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods: The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set not to exceed the dose limit for the lens. Results and Discussion: In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 examples. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion: With the development of the guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimize radiation protection.

HPGe 검출기에서 환경방사능측정의 검출하한치에 관한 연구 (A Study on Minimum Detection Limit of Environmental Radioactivity in HPGe Detector)

  • 장은성
    • 한국방사선학회논문지
    • /
    • 제5권1호
    • /
    • pp.5-10
    • /
    • 2011
  • 검출한계에 대한 기본개념을 기초로 백그라운드 측정시간과 시료측정시간을 고려하였고, 환경시료중에서 육상시료(하천토, 표층토양, 식수, 지하수, 지표수, 솔잎, 쑥) 분석에서 백그라운드 계측시간과 시료 측정시간의 변화에 따른 MDA 값들을 비교하였다. 물시료 분석결과를 살펴보면 대부분 시료에서 불검출로 나타났으며, 육상시료 분석결과 대부분의 시료에서 "과학기술부고시 제 2008-28호"의 검출하한치 미만으로 측정되었으나, 일부 시료에서는 인공방사성핵종인 $^{137}Cs$이 검출되었다. 이는 과거 50.60년대 행해졌던 대기권 핵실험에 의한 낙진 및 소련의 체르노빌 원전사고 등에 의한 영향으로 우리나라뿐만 아니라 전 세계적으로 검출되고 있는 수준이다. 또한 $^{137}Cs$의 동위원소이며, 상대적으로 반감기가 짧은 $^{134}Cs$가 모든 시료에 대해서 검출되지 않는 것으로 보아 원전운영에 의한 영향이 아님을 알 수 있다.

N 도핑된 TiO2 광촉매 박막의 제조 및 특성분석 (Manufacturing and Characterization of N-doped TiO2 Photocatalytic Thin Film)

  • 박상원;남수경;허재은
    • 한국환경과학회지
    • /
    • 제16권6호
    • /
    • pp.683-688
    • /
    • 2007
  • In this study, N doped $TiO_2$ (TiO-N) thin film was prepared by DC magnetron sputtering method to show the photocatalytic activity in a visible range. Various gases (Ar, $O_2\;and\;N_2$) were used and Ti target was impressed by 1.2 kW -5.8 kW power range. The hysteresis of TiO-N thin film as a function of discharge voltage wasn't observed in 1.2 and 2.9kW of applied power. Cross sections and surfaces of thin films by FE-SEM were tiny and dense particle sizes of both films with normal cylindrical structures. XRD pattern of $TiO_2$ and TiO-N thin films was appeared by only anatase peak. Red shift in UV-Vis adsorption spectra was investigated TiO-N thin film. Photoactivity was evaluated by removal rate measurement of suncion yellow among reactive dyes. The photodegradation rate of $TiO_2$ thin film on visible radiation was shown little efficiency but TiO-N was about 18%.

대형증발계용 매시간 증발 기록계 개발에 관한 연구 (A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan)

  • 이부용
    • 한국환경과학회지
    • /
    • 제10권5호
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF

몬테카를로 시뮬레이션에서의 다양한 환경 샘플에 대한 Marinelli 비이커 측정 및 자기 흡수 보정과 적용 (Marinelli Beaker Measurement and Self Absorption Correction and Application for Various Environmental Samples in Monte Carlo Simulation)

  • 장은성;김양수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.605-611
    • /
    • 2017
  • 검출기의 구조를 PENELOPE의 코드를 사용하여 전산모사 하였다. 표준혼합시료(450, 1,000 ml)를 사용하여 다양한 밀도와 높이에 따른 저에너지(59.54 keV)부터 고 에너지(1,836.05)에 대한 측정효율과 PENELOPE 전산모사에서 구한 효율을 비교하였으며, 또한 자체흡수에 대한 효율을 보정하여 다양한 환경시료에 적용하여 검출하한치를 알아보고자 한다. 표준혼합선원의 전체에너지 피크효율 값을 적용하여 높이에 따른 효율변화를 측정치와 PENELOPE의 전산모사 값과 비교하였다. 여기서 구한 값들을 자체흡수 보정하여 구한 효율을 실제 환경시료에 적용하여 검출하한치 값들을 구하였다. 밀도보정인자는 밀도가 $0.4g/cm^3$에서 241Am(59.54 keV)의 밀도보정인자는 1.15, PENELOPE 전산모사에서는 1.153, 137CS(661.66 keV) 에서는 $1.06g/cm^3$, PENELOPE 전산모사에서는 1.064, 88Y(1,836.04 keV)에 대한 밀도보정인자는 1.03, PENELOPE 전산모사에서는 1.033으로 불확도는 1% 이내에서 잘 일치함을 확인하였다. 환경 시료의 밀도에 따른 방사능 농도는 시료량이 많을수록, 측정시간이 증가할수록 MDA(Minimum Detectable Activity) 값이 감소함을 확인할 수 있었다.

바닥공조 시스템이 적용된 사무공간의 거주후 성능평가 (Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System)

  • 윤성훈;장향인;정해권;최선규;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

함침형 액막을 이용한 Calcium 함유 용액으로부터 Strontium의 선택적 분리 (Selective separation of Strontium in the solution containing Calcium by Supported Liquid Membrane)

  • 최영우;문승현;이창우
    • Journal of Radiation Protection and Research
    • /
    • 제24권1호
    • /
    • pp.9-15
    • /
    • 1999
  • 칼슘을 함유한 방사성 환경시료 용액으로부터 스트론튬을 분리하기 위한 방법으로 함침형 액막을 제조하여 그 분리특성을 고찰하였다. 운반체로 사용된 DC18C6과 DNNS의 농도에 따라 금속이온 투과도와 스트론튬 선택도에 영향을 미쳤으며, 특히 0.1M DC18C6과 25mM DNNS을 함침시켜 제조한 액막의 경우에서 93.3%의 스트론튬 선택도를 얻을 수 있었다. 모의용액의 스트론튬에 대한 칼슘의 함량비가 1 : 25 - 1 : 50일 때 스트론튬 선택성이 90% 이상으로 나타났으며, 따라서 본 연구에서 제조한 액막은 스트론튬 측정을 위한 해수 환경시료의 전처리에 적용 가능할 것으로 생각된다.

  • PDF