References
- Kitto. M. E. Determination of photon self-absorption correction for soil samples. Apply. Radiation Isotope, 1991;42(9):835-839. https://doi.org/10.1016/0883-2889(91)90221-L
- Hasan. M. A simplified technique to determine the self-absorption correction for dediment samples. Apply. Radiation Isotope. 2002;57:915-918 https://doi.org/10.1016/S0969-8043(02)00169-0
- Dryak. P. Corrections for the Marinelli geometry. Radiation Nuclear Chemistry, 1989;135(4):281-292. https://doi.org/10.1007/BF02164586
- Sanchez .F, Navarro. E, J. Ferrero. L, Moreno. A, Roldan. C, Baeza. A and Paniagua. J. A Monte Carlo based method of including gamma self-absorption for the analysis of environmental samples. Nuclear Instruments and Methods, 1991;B61:535-540.
- Debertin K and Jianping. R. Measurement of the activity of radioactive samples in Marinelli beakers. Nuclear Instruments and Methods, 1989;A278:541-549.
- Bar'o Juie. J. Sempau, Ja .Mack. Fern'andez-Varea and F. Salvat. PENELOPE: an algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter. Nuclear. Instrument. Methods. 1995;B 100:31-46.
- Jang. Eun. Sung, Chang. Bo. Seok. A Germanium Detector Structure PENELOPE Characteristic Analysis by Computer Simulation, Jour of Korea Society of Radiology, 2015;2:73-77.
- Wainio. K. M and Knoll. G. F. Calculated gamma ray response characteristics of semiconductor detectors. Nuclear Instruments and Methods. 1966;44:213-223. https://doi.org/10.1016/0029-554X(66)90153-4
- B. Lal and K. V. K. lyengar. Monte Carlo calculations of gamma ray response characteristics of cylindrical Ge(li) detectors. Nuclear Instruments and Methods, 1970;79:19-28. https://doi.org/10.1016/0029-554X(70)90004-2
- Gaggero. G. Monte Carlo calculations for the photo fractions and energy loss spectra of Ge(li) semiconductor detectors. Nuclear Instruments and Methods, 1971;94:481-492. https://doi.org/10.1016/0029-554X(71)90010-3
- Meixner. Ch. A Monte Carlo program for the calculation of gamma-ray spectra for germanium detectors. Nuclear Instruments and Methods, 1974;119:521-526. https://doi.org/10.1016/0029-554X(74)90802-7
- Nakamura. T. Monte Carlo calculation of reak efficiencies and response functions of coaxial-type Ge(li) detectors for disk gamma-ray sources. Nuclear Instruments and Methods, 1975;131: 521-527. https://doi.org/10.1016/0029-554X(75)90444-9
- Moss. C. E. Moss and Street man. J. R. Comparison of calculated and measured response functions for germanium detectors. Nuclear Instruments and Methods, 1990;A299:98-101
- Abbas. M.I. HPGe detector photo-peak efficiency calculation including self-absorption and coincidence corrections for Marinelli beaker sources using compact analytical expressions. Applied Radiation Isotope, 2001;54:761-768. https://doi.org/10.1016/S0969-8043(00)00308-0
- Saegusa. Jun, Katsuya Kawasaki, Akira Mihara, Mitsuo Ito, Makoto Yoshida. Determination of detection efficiency curves of HPGe detectors on radioactivity measurement of volume samples. Applied Radiation and Isotopes, 2004;61:1383. https://doi.org/10.1016/j.apradiso.2004.04.004
- Debertin K. and Grosswendt B. Efficiency calibration of semiconductor detectors by primary standard sources and Monte Carlo calculations. Nuclear Instruments and Methods in Physics Research, 1982;203:343-353 https://doi.org/10.1016/0167-5087(82)90646-9
- Nakamura T, uzuki T. Monte Carlo calculation of peak efficiencies of Ge(Li) and pure Ge detectors to voluminal sources and comparison with environmental radioactivity measurement. Nuclear Instruments and Methods in Physics Research, 1983;205:211-218 https://doi.org/10.1016/0167-5087(83)90191-6
- Birattari C, Salomone A. Please edit your search query to find results. Nuclear Instruments and Methods in Physics Research, 1900;174:391