• 제목/요약/키워드: Environmental Quality

검색결과 9,570건 처리시간 0.039초

2009년 서울지역 황사 및 고농도 미세먼지 사례 시 미세먼지의 화학성분 특성 (Chemical Characteristics of Ambient Aerosol during Asian Dusts and High PM Episodes at Seoul Intensive Monitoring Site in 2009)

  • 박승명;문광주;박종성;김현재;안준영;김정수
    • 한국대기환경학회지
    • /
    • 제28권3호
    • /
    • pp.282-293
    • /
    • 2012
  • This study aimed to show the chemical characteristics of $PM_{10}$ and $PM_{2.5}$ during Asian dust (AD) events and high PM episodes observed in Seoul. Time-resolved chemical composition of $PM_{10}$ or $PM_{2.5}$ was monitored in 1 hour interval using ambient ion monitor, semi-continuous carbon monitor, and on-line XRF spectrometer at Seoul intensive monitoring site in 2009. Considering that AD events were classified into three different cases according to the source area and pathway, the concentrations of ammonium-sulfate and trace metal components were relatively high when the AD were occurred in Gobi and inner-mongolia and transported across the Bohai bay. In addition, the influence of alkaline dust, which carried from saline land located in the northeastern China, was observed when the AD was originated from Gobi, inner-mongolia, and Manchuria. Except AD events, the high PM episodes observed in Seoul were impacted by various anthropogenic sources such as biomass burning, motor vehicle, oil combustion and road dust.

Association between sleep quality and type of shift work in Korean firefighters

  • Hyun-Jeong Oh;Chang Sun Sim;Tae-Won Jang;Yeon Soon Ahn;Kyoung Sook Jeong
    • Annals of Occupational and Environmental Medicine
    • /
    • 제34권
    • /
    • pp.27.1-27.12
    • /
    • 2022
  • Background: Shift work that interferes with normal sleep patterns, is known to be a cause of sleep disturbance and has been studied through various occupational groups. However, it is not known which shift type is better for sleep health. Methods: This study included 568 firefighters. Sleep quality was evaluated using Pittsburgh Sleep Quality Index. Sleep quality was categorized into 2 groups; good quality (≤ 5 points) and poor quality (≥ 6 points). Demographic variables, depression, anxiety, type of shift, and job were collected by self-reported questionnaires. The χ2 test, t-test, and multiple logistic regression analysis were used to evaluate the effect of shift type on the sleep quality of firefighters. Results: Three hundred thirty-seven firefighters (59.3%) have poor sleep quality. Compared to day workers, the odds ratios (ORs) of poor sleep quality were 2.169 (95% confidence interval: 1.137-4.134) in 6-day cycle, 2.161 (1.150-4.062) in 9-day cycle, 1.805 (1.087-2.997) in 21-day cycle, and 1.485 (0.718-3.069) in 3-day cycle. The ORs of poor sleep quality were 1.697(1.021-2.823) in fire suppression and 2.325 (1.213-4.455) in emergency medical service compared to administration. Conclusions: All shift work type except for the 3-day cycle was associated with poor sleep quality compared to day work.

대기질 영향평가와 예측방법에 대한 개선방향 (A Method of Improving Air Quality Impact Assessment and Prediction)

  • 박종길;원경미;김성수
    • 한국환경과학회지
    • /
    • 제3권2호
    • /
    • pp.77-88
    • /
    • 1994
  • When we conduct environmental impact assessment, main contents consist of summary, project outline, environmental conditions, environmental impacts due to the project, mitigation devices, and alternative measures of harmful impact on environment. In this Paper, to understand how they really conduct air quality impact assessment and prediction and examine their effectiveness, we considered the provisions and actual case of environmental impact assessment in Korea with that in Japan. As a result, we propose a method of improving air quality impact assessment and Prediction, such as reflection of the result in environmental impact assessment, detailed assessment focused on relatively important environmental impact elements, field measurement investigation over four season and seven sucessive days, the uniformity of units, the proper model development to predict environmental concentration and a biennial environmental impact assessment for ex post management.

  • PDF

환경영향평가시 대기확산모델의 사용현황과 개선방안 (Review on Air Quality Modeling in Environmental Impact Assessments)

  • 김석철;이영수
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.827-841
    • /
    • 1999
  • The air quality simulation models in wide use for air quality impact assessmetns are reviewed. After an intensive survey and comparative study upon the environmental impact assessment reports submitted to Ministry of Environment during 1990~1998, we could identify the major common problems with the air quality impact assessment procedures. Several remedies are presented here, including use of the screening models applicable to the complex terrain.

  • PDF

The Long Term Trends of Tropospheric Ozone in Major Regions in Korea

  • Shin, Hye Jung;Park, Ji Hoon;Park, Jong Sung;Song, In Ho;Park, Seung Myung;Roh, Soon A;Son, Jung Seok;Hong, You Deog
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권4호
    • /
    • pp.235-253
    • /
    • 2017
  • This study was conducted for analyzing the contribution factors on ozone concentrations and its long term trends in each major city and province in Korea through several statistical methods such as simple linear regression, generalized linear model, KZ-filer, correlation matrix, Kringing method, and cluster analysis. The overall ozone levels in South Korea have been consistently increasing over the past 10 years. The ozone concentrations in Seoul, the biggest city in Korea, are the lowest in all areas with the highest increasing ratio for $95^{th}%$ ozone. It is thought that the active photochemical reaction could affect the higher ozone concentration increase. On the other hand, the ozone concentrations in Jeju are the highest in Korea with the highest increasing ratio for $5^{th}%$, $33^{th}%$, and $50^{th}%$ ozone. It is also thought that the weak $NO_x$ titration could be the reason of higher ozone concentrations in Jeju. In case of Jeju, transport related factors is the major factor affecting the ozone trend. Thus, it is assumed that the variation of ozone trend of Asian region affecting the ozone trend in Jeju, where domestic ozone photochemical reaction is less active than urban area. It is thought that the photochemical reaction plays the role of increasing of ozone concentrations in the urban area, even though the LRT affected on the increase of ozone concentrations in non-urban area.

경향성 및 패턴 분석을 이용한 낙동강 물금지역의 수질 특성 (Characteristics of Trend and Pattern for Water Quality Monitoring Networks Data using Seasonal-kendall, SOM and RDA on the Mulgeum in the Nakdong River)

  • 안정민;이인정;정강영;김주언;이권철;천세억;류시완
    • 한국환경과학회지
    • /
    • 제25권3호
    • /
    • pp.361-371
    • /
    • 2016
  • Ministry of Environment has been operating water quality monitoring network in order to obtain the basic data for the water environment policies and comprehensively understand the water quality status of public water bodies such as rivers and lakes. The observed water quality data is very important to analyze by applying statistical methods because there are seasonal fluctuations. Typically, monthly water quality data has to analyze that the transition comprise a periodicity since the change has the periodicity according to the change of seasons. In this study, trends, SOM and RDA analysis were performed at the Mulgeum station using water quality data for temperature, BOD, COD, pH, SS, T-N, T-P, Chl-a and Colon-bacterium observed from 1989 to 2013 in the Nakdong River. As a result of trends, SOM and RDA, the Mulgeum station was found that the water quality is improved, but caution is required in order to ensure safe water supply because concentrations in water quality were higher in the early spring(1~3 month) the most.

탐진강 수질측정 지점 간 동질성 검정을 위한 비모수적 자료 분석 (A Non-parametric Analysis of the Tam-Jin River : Data Homogeneity between Monitoring Stations)

  • 김미아;이수웅;이재관;이정섭
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.651-658
    • /
    • 2005
  • The Non-parametric Analysis is powerful in data test especially for the non- normality water quality data. The data at three monitoring stations of the Tam-Jin River were evaluated for their normality using Skewness, Q-Q plot and Shapiro-Willks tests. Various constituent of water quality data including temperature, pH, DO, SS, BOD, COD, TN and TP in the period of January 1994 to December 2004 were used as dataset. Shapiro-Willks normality test was carried out for a test 5% significance level. Most water quality data except DO at monitoring stations 1 and 2 showed that data does not normally distributed. It is indicating that non-parametric method must be used for a water quality data. Therefore, a homogeneity was conducted by Mann-Whitney U test (p<0.05). Two stations were paired in three pairs of such stations. Differences between stations 1, 2 and stations 1, 3 for pH, BOD, COD, TN and TP were meaningful, but Tam-Jin 2 and 3 stations did not meaningful. In addition, a narrow gap of the water quality ranges is not a difference. Categories in which all three pairs of stations (1 and 2, 2 and 3, 1 and 3) in the Tam-Jin River showed difference in water quality were analyzed on TN and TP. The results of in this research suggest a right analysis in the homogeneity test of water quality data and a reasonable management of pollutant sources.

온산 항만 시스템에서 조류와 수질 변화 시뮬레이션 (Simulation of Tidal Flow and Water Quality in Onsan Harbor System)

  • 김소연;박석순
    • 환경영향평가
    • /
    • 제8권3호
    • /
    • pp.13-22
    • /
    • 1999
  • Tidal flow and water quality were simulated in this paper to assess environmental impact caused by pier construction projects in Onsan harbor system. The Surfacewater Modeling System (SMS) was applied to the Onsan harbor system, where coastal reclamation and dredging were planned to build the piers. A finite element mesh was constructed and refined to cover the complicated geometry of the Onsan harbor and the proposed reclamation area. The time variable change of tidal height at harbor inlet was given as an input condition to tidal simulation. The water quality simulation was based on the discharge rate of suspended solids at the reclamation area. The simulation results have shown reasonable agreements with real situations in both tidal flow and water quality. According to the proposed plan, tidal flow and water quality were predicted during and after the pier construction. The tidal simulation study showed that there would be no discernible change of tidal current in the harbor except for the dredged area. The water quality simulation, however, predicted that suspended solids would increase significantly near the reclaimed and dredged areas during construction.

  • PDF

The Impact of Franchise Dessert Cafe Quality on Consumption Value, Satisfaction, and Loyalty

  • Sae-Mi LEE;Dong-Woo KOO;Debora LEE
    • 한국프랜차이즈경영연구
    • /
    • 제15권3호
    • /
    • pp.45-55
    • /
    • 2024
  • Purpose: This study examines the impact of dessert cafe quality factors-interaction, environmental, outcome, and product quality-on hedonic and utilitarian values, satisfaction, and loyalty. It explores how these elements influence consumer behavior in the context of dessert cafe experiences. Research design, data and methodology: Data were collected from 563 consumers who visited dessert cafés within the last three months. The analysis was conducted using SPSS 28.0 and SmartPLS 4.0 to test the relationships among the café quality factors, consumption values, satisfaction, and loyalty. Result: Interaction, environmental, outcome, and product quality positively influenced hedonic value. Interaction and outcome quality impacted utilitarian value, while environmental and product quality did not. Satisfaction was positively affected by environmental and product quality but not by interaction or outcome quality. Satisfaction influenced loyalty, while neither hedonic nor utilitarian value significantly impacted loyalty. Conclusions: The study highlights the importance of understanding how different quality dimensions in dessert cafés affect consumer satisfaction and loyalty. The findings provide valuable insights for enhancing customer experiences and formulating effective marketing strategies in the dessert cafe industry.

철도소음환경 기준설정을 위한 기초적 연구(I) (A Fundamental Study on the Establishment of Environmental Quality Criteria for Railway Noise(I))

  • 고광필;김명재;기노갑;장길수;김선우
    • KIEAE Journal
    • /
    • 제2권1호
    • /
    • pp.69-76
    • /
    • 2002
  • With rapid industrial development, railway has become a main traffic means. But, the railway noise has caused much annoyance for the residents living nearby railway track. Therefore, it is necessary to establish the environmental Quality criteria for railway noise like the environmental quality criteria for traffic noise. In this study, the domestic and foreign criteria for railway noise were investigated with analysis of existing data and an field survey of noise condition near a railway. Fundamental data are provided for establishment of environmental Quality criteria for railway noise.