• Title/Summary/Keyword: Environment humidity

Search Result 1,651, Processing Time 0.028 seconds

A Study on Examination of Indoor Thermal Environment Elements and Thermal Sensation Vote of Log Cabins in Winter Season (통나무집의 동절기 실내 온열환경 요소의 측정과 온열감 평가에 관한 연구)

  • Min, Byeong-Cheol;Jeon, Ji-Hyeon;Kook, Chan
    • Journal of the Korean housing association
    • /
    • v.18 no.2
    • /
    • pp.21-27
    • /
    • 2007
  • Various buildings constructed by environmentally friendly resources are being built in KOREA. Especially as the wood has distinctive ecological merits in comparison with reinforced concrete and brick, the buildings made by the wood are acknowledged with its superiority of ecological value. Enough field studies for their thermal environment, however, haven't been done. In this study, to investigate indoor environmental condition and occupants' response to it of Log Cabin in Gyeongsangnam-do Hamyang Country Jirisan Natural Recreation Forest, examination of indoor thermal environment and field subjective evaluation have been done in that fundamental information of thermal environment characteristics can be suggested. The results are following; 1) Thermal environment of the Log Cabins; Indoor and outdoor mean dry bulb temperature were $21.9^{\circ}C$ and $-3.1^{\circ}C$, and Indoor and outdoor average relative humidity were 25.8% and 52.1%. These results are below ASHRAE; dry bulb temp. $22.0^{\circ}C$, humidity 30%, and above domestic standards; dry bulb temp. $18{\sim}20.0^{\circ}C$, humidity $40{\sim}60%$. 2) Result of subjective evaluation; Thermal sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. And humid sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. 3) Result of vertical temperature and humidity; Vertical temperature difference from head to ankle was $0.54^{\circ}C$ which means most occupants may feel comfortable.

Investigation of Standard Error Range of Non-Contact Thermometer by Environment (외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정)

  • Kim, Jeongeun;Park, Sangwoong;Choi, Heakyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

Development of Methods for Evaluation of Indoor Thermal Environment of Apartment Housing (공동주택의 실내 열환경에 대한 평가방법개발)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.6
    • /
    • pp.101-110
    • /
    • 1997
  • The intent of this study is to propose a method for appraisal of the indoor thermal environment of apartment housing by measuring physical factors and residents' response to questionnaire survey. The experiments were performed on eight houses each in summer (August 18 through 31,1995) and winer (february 16 through 20,1996). It included measurements of indoor air temperature, globe temperature, relative humidity, and CO2 concentration. The questionnaire surveys were performed each in summer (July 16 through 20, 1996) and winer (February 13 through 16, 1996). And 248 cases in summer and 297 cases in winter were used in analysis. These questionnaire surveys asked residents' response about thermal sensation, humidity sensation, sense of air freshness regarding the indoor thermal environment. data acquired through the experiments and questionnaire surveys were then transferred to scales that allowed relative comparison, and measured to an appraisal standard chart. Appraisal tools included appraisal charts and radar charts. Indoor thermal environment was judged to be positive according to experiments, but residents appraised the thermal environment to be average. This difference between the two can be found in the strict standards by which residents judge the thermal environment of their apartments.

  • PDF

A Study on Thermal Comfort of Korea Men감s Wear in Summer - Based on Indoor Environment conditions - (하계 남성복의 온열쾌적감에 관한 연구 - 실내 환경조건을 중심으로 -)

  • 정상열;고경태
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1997.10a
    • /
    • pp.364-368
    • /
    • 1997
  • The purpose of this Study was to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate Variability(HRV), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at 50% R.H., 24C, and the difference of skin temperature was found at the calf area as air temperature changes. At low air temperature and low humidity, heart rate was decreased, but there was no change at brain wave, keeping a-wave.

  • PDF

Greenhouse environment analysis -Distributions and Variations of Temperature , Relative humidity Illumination , Carbon dioxide and Wind Velocity-

  • Kim, Y.B;Park, J.C.;Song, H.K.;Paek, Y.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.478-486
    • /
    • 1993
  • For satisfactory greenhouse culture, environmental factors must be kept in proper conditions. Therefore, it is important to know relations between environmental conditions and greenhouse systems. In this study, the environment variations and distributions in different types of greenhouses were measured and analyzed. The elements of environment analyzed were temperature , relative humidity, illumination, carbon dioxide and wind velocity. The analyzed greenhouse types were three different types. One of them, A type, was propagation model type by government and the other one, B type, was multiple continuous arches type which was made by farmers himself. The last one, C type, was single arch type which has no environment control system without manual temperature keeping method. The results of this study can be used for reasonable greenhouse environments managements and control.

  • PDF

Effects of Buffering Zone Installation on the Temperature and Humidity of Pig House and Mortality of Weaned Pig (완충공간의 설치가 이유자돈사 온·습도변화 및 자돈 폐사율에 미치는 영향)

  • Lee, Jun-Yeob;Lee, Dong-Hyun;Woo, Saem-Ee;Choi, Hee-Cheol
    • Journal of Animal Environmental Science
    • /
    • v.21 no.3
    • /
    • pp.77-82
    • /
    • 2015
  • This survey was conducted to collect basic data about the effect of buffering zone installation in weaned pig house. Buffering zone was installed either inside or outside of pig house to compare changes of temperature, humidity and air velocity of pig room. The body weight and mortality of weaned pigs in house with buffering zone was also measured. There was no difference in temperature, humidity and air velocity between inside and outside buffering zone. Mortality of weaned pig in house with buffering zone was drastically decreased compare to pigs in house without buffering zone that could be useful to maintain constant temperature and decrease mortality.

Properties of Water Permeability and Porosity of Cement Mortar Substrate Coated with Siliceous Slurry Coating under Exposure Enviorment (폭로환경하에서 규산질미분말혼합 시멘트계 도포방수재가 바탕모르터의 투수성과 세공구조에 미치는 영향)

  • 김형무;오상근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.175-182
    • /
    • 1996
  • This paper deals with the properties of water permeability and porosity of cement mortar substrate coated with siliceous slurry coating under the exposure environment. Conditions of exposure enviornment are four kinds of in constant temperature water and humidity box, in indoor and outdoor exposure. Coated mortar substrate was expected continually increase in water and humidity condition, but was not in dry condition. Watertightness effect of siliceous coating was better in the condition of humidity then the dry condition, and the pore volume was decreased in that condition.

  • PDF

Experimental Study on the Moisture Distribution in Concrete Specimens According to Different Compressive Strengt (콘크리트 강도차에 따른 함수율 분포의 변동에 관한 실험적 연구)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.195-196
    • /
    • 2019
  • The temperature and relative humidity in concrete change with the passage of time depending on factors such as compressive strength. They are also different depending upon internal depth of concrete. In this study, we have measured the change of the temperature and relative humidity in the concrete for two years to act as the parameters to evaluate the concrete durability and effective maintenance.

  • PDF

Analyzing Change of Discomfort Index for Transpiration of Street Tree (도시 가로수의 증산 작용으로 인한 불쾌지수 변화 분석)

  • Yun, Seok-Hwan;Lee, Dong-Kun;Park, Chae-Yeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.5
    • /
    • pp.29-43
    • /
    • 2020
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. The cooling effect of street tree is regarded as a effective way to ameliorate the urban heat environment. The effect is largely made up of shadow formation and transpiration. This study aims to identify how the transpiration affects the discomfort index by analyzing comprehensive impact of the transpiration on the air temperature and relative humidity. The changes in the amount of transpiration, air temperature, and relative humidity were estimated for Seogyo-dong area which has a lot of floating population in Seoul, at 2 p.m. in dry day in July and August. On average, the transpiration of the street tree decreased the temperature 0.3℃ and increased the relative humidity 2.6% in an hour. As a result of these changes in temperature and humidity, the discomfort index rose mostly(0.036 on average). It was always get rise especially on the day when the discomfort index was above 80(0.05 on average). However, compared with the significant change in temperature and humidity, the variation of the discomfort index itself was very slight(up to 0.107). Therefore, the effect of transpiration by the street trees might not be effective in the planning to improve the thermal environment(especially on the day when the discomfort index is high). It is necessary to select the species of trees and planting location considering the cooling effect of shade formation synthetically.

Tribological properties of ultra-thin diamond-like carbon coating at various humidity

  • Cuong, Pham Duc;Ahn, Hyo-Sok;Kim, Choong-Hyun;Kim, Doo-In
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.161-162
    • /
    • 2002
  • This study concerns the tribological behaviors of ultra-thin DLC coating with 3 nm thickness deposited in a mixed gas of argon + 20 % hydrogen as a function of humidity. Reciprocating wear tests employing a micro wear tester were performed under various normal loads and relative humidity in air environment. The chemical composition of the original and worn surfaces were studied by Auger electron spectroscopy (AES). It showed that the ultra-thin DLC coating exhibited low friction with enough wear stability at low normal load (0.18 N) and its tribological behavior was strongly dependent on the humidity. The sample surfaces before and after the test were examined using atomic force microscopy (AFM). Capillary force and meniscus areas were discussed in order to explain the influence of humidity on the friction force.

  • PDF