• Title/Summary/Keyword: Envelope surface

Search Result 167, Processing Time 0.026 seconds

Treatment of Pilon Fracture using Articulated External Fixator with Hinge (경첩 운동이 가능한 외고정장치를 이용한 Pilon골절의 치료)

  • Park, In-Heon;Lee, Kee-Byung;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.1
    • /
    • pp.30-37
    • /
    • 1997
  • Pilon fracture is an intraarticular fracture of distal tibia. It is high energy injury with significantly associated soft tissue damage, bone comminution, and articular surface disruption. Until recently, this treatment has followed the AO principles, Because the risk of complications outweighs potential benefits, the principle of a Pilon fracture treatment are changing. Newer techniques using articulated external fixation minimize disturbance of the soft tissue envelope and have decreased these complications. Series of 5 patients with Pilon fracture were treated by articulated external fixator and followed up more than 12 monthes at the Department of orthopaedic surgery, Kang Dong Sacred Heart Hospital, College of medicine, Hallym University. The results were as follows: 1. The type of fracture were type C2(3 cases),type C3(2 cases) according to AO-$M{\ddot{u}}ller$ classification. 2. The clinical results according to functional criteria by Mast and Teipner were good in 4 cases and poor in 1 case, which is an old fracture. 3. Techniques utilizing articulated external fixator were associated with satisfactory results and appeared to significantly decrease the incidence of soft tissue complication, post-traumatic arthritis, osteoporosis, and fibrosis of ankle joint.

  • PDF

Threshold Crossing Rate, Phase Distribution and Group Properties of Nonlinear Random Waves of finite Bandwidth (유한한 Bandwidth를 갖는 비선형 불규칙 파열에서의 Threshold Crossing Rate, 위상분포와 파군특성)

  • Jo, Yong-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.3
    • /
    • pp.225-233
    • /
    • 1997
  • The nonlinear effects on the statistical properties of wave groups in terms of the average nomber of waves in a group and the mean number of waves in a high run is studied in this paper utilizing the complex envelope and total phase function, random variable transformation technique and perturbation method. It tures out that the phase distribution is modified significantly by nonlinearities and it show systematic excess of values near the mean phase and the corresponding symmetrical deficiency on both sides away from the mean. for the case of threshold crossing rate, it turns out that threshold crossing rate reaches its maxima just below the mean water level rather than zero and considerable amount of probability mass is shifted toward the larger values of water surface elevation as nonlinearity is getting profound. Furthermore, the mean waves in a high run associated with nonlinear wave are shown to have larger values than the linear counterpart. Similar trend can also be found in the average number of waves in a group.

  • PDF

The use and potential applications of point clouds in simulation of solar radiation for solar access in urban contexts

  • Alkadri, Miktha F.;Turrin, Michela;Sariyildiz, Sevil
    • Advances in Computational Design
    • /
    • v.3 no.4
    • /
    • pp.319-338
    • /
    • 2018
  • High-performing architecture should be designed by taking into account the mutual dependency between the new building and the local context. The performative architecture plays an important role to avert any unforeseen failures after the building has been built; particularly ones related to the microclimate impacts that affect the human comfort. The use of the concept of solar envelopes helps designers to construct the developable mass of the building design considering the solar access and the site obstruction. However, the current analysis method using solar envelopes lack in terms of integrating the detailed information of the existing context during the simulation process. In architectural design, often the current site modelling not only absent in preserving the complex geometry but also information on the surface characteristics. Currently, the emerging applications of point clouds offer a great possibility to overcome these limitations, since they include the attribute information such as XYZ as the position information and RGB as the color information. This study particularly presents a comparative analysis between the manually built 3D models and the models generated from the point cloud data. The modelling comparisons focus on the relevant factors of solar radiation and a set of simulation to calculate the performance indicators regarding selected portions of the models. The experimental results emphasize an introduction of the design approach and the dataset visibility of the 3D existing environments. This paper ultimately aims at improving the current architectural decision of support environment means, by increasing the correspondence between the digital models for performance analysis and the real environments (context of design) during the conceptual design phase.

A Study on the Performance Comparisons of Air Type BIPVT Collector Applied on Roofs and Facades (건물 적용 유형별 공기식 BIPVT 유닛의 전기 및 열성능 비교에 관한 연구)

  • Kang, Jun-Gu;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.56-62
    • /
    • 2010
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. PV/thermal collectors, or more generally known as PVT collectors, are devices that operate simultaneously to convert solar energy from the sun into two other useful energies, namely, electricity and heat. This paper compares the experimental performance of BIPVT((Building-Integrated Photovoltaic Thermal) collectors that applied on building roof and facade. There are four different cases: a roof-integrated PVT type and a facade-integrated PVT type, the base models with an air gap between the PV module and the surface, and the improved models for each types with aluminum fins attached to the PV modules. The accumulated thermal energy of the roof-integrated type was 15.8% higher than the facade-integrated regardless of fin attachment. The accumulated electrical energy of the roof-integrated type was 7.6% higher, compared to that of the facade-integrated. The efficiency differences among the collectors may be due to the fact that the pins absorbed heat from the PV module and emitted it to air layer.

Arthroscopic Evaluation for Endoscopic ACL Reconstruction Using a Multi-stranded Hamstring Tendon Graft and EndoButton (슬괵 건을 이용한 전방십자인대 재건술후 2차 관절경적 평가)

  • Lee, Kwang-Won;Lee, Byeong-Ki;Ryu, Chang-Soo;Keum, Teok-Seop;Choy, Won-Sik;Kim, Joon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.124-128
    • /
    • 1998
  • From Feb. 1996 to Feb. 1997. among sixty-four patients of anterior cruciate ligament(ACL) reconstruction using multi-stranded hamstring tendon and EndoButton fixation, twenty-five patients of volunteer, 15 men and 10 women, from 16 to 50 years of age(mean 27.6 years) underwent arthroscopic evaluation. Arthroscopic evaluation was routinely performed one year after surgery along with an examination of stability. The purpose of this study was to arthroscopically evaluate the morphological changes that occurred in hamstring tendon autograft one year after ACL reconstruction. Both of the tendon graft and the adjacent fibrous tissues were observed for gross appearance and physical properties with probing and response to passive anterior translation. Biopsy samples were taken from the surrounding fibrous tissue and the tendon graft. Grossly, we found a well-defined ligamentous structure with good tension tested with a probe. A common finding was that the reconstructed ligaments were embedded in a layer of the synovium, and blood vessels could be seen on the anterior surface of the ligament. The biopsy tissue was placed in formalin solution and subjected to histological preparation by hematoxylin and eosin staining method. The hamstring tendon graft appeared histologically normal under light microscopic finding. There were a few vessels located between existing collagen bundles, and the vessels had an orderly pattern. The surrounding fibrous tissue envelope was covered with synovium. We pleased with preliminary findings in our evaluation.

  • PDF

Isolation and Characterization of White Spot Syndrome Baculovirus in Cultured Penaeid Shrimp (Penaeus chinensis) (양식새우(Penaeus chinensis)에서의 White Spot Baculovirus의 분리 및 특성)

  • Heo, M.S.;Sohn, S.G.;Sim, D.S.;Kim, J.W.;Park, M.A.;Lee, J.S.;Choi, D.L.;Jung, S.H.;Kim, Y.J.;Oh, M.J.
    • Journal of fish pathology
    • /
    • v.13 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • Beginning in the summer of 1993, a serious mortality among cultured penaeid shrimp occurred in the western sea of Korea. The typical sign of this disease was white spots inside the surface of the carapace. Cytopathic effect (CPE) were not observed by virus in CHSE-214, RTG-2, but not by pH 11. A nonoccluded rod-shaped form virus was observed by electron microscopy in the lymphoid organ. The virion was bacilliform virus and sourrounded by a virion envelope. Its virion protein was found to be similar to hypodermal and hematopoietic necrosis virus (HHNBV) by analysis of virion proteins in SDS-PAGE. The genome of virus is double stranded DNA molecule whose full length was about 114kb. It was similar to penaeus acute viremia (PAV) of Japan.

  • PDF

Investigation of the Effects of UAV Nozzle Configurations on Aircraft Lock-on Range (무인항공기의 노즐 형상 변화가 Lock-on Range에 미치는 영향에 관한 연구)

  • Kim, Min-Jun;Kang, Dong-Woo;Myong, Rho-Shin;Kim, Won-Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.3
    • /
    • pp.204-212
    • /
    • 2015
  • The infrared lock-on range of target aircraft plays a critical role in determining the aircraft survivability. In this investigation, the effects of various UAV engine nozzle configurations on the aircraft lock-on range were theoretically analyzed. A virtual subsonic aircraft was proposed first, based on the mission requirement and the engine performance analysis, and convergent-type nozzles were then designed. After determining thermal flow field and nozzle surface temperature distribution with the CFD code, an additional analysis was conducted to predict the IR signature. Also, atmospheric transmissivity for various latitude and seasons was calculated, using the LOWTRAN code. Finally, the lock-on and lethal envelopes were calculated for different nozzle configurations, assuming the sensor threshold of the given IR guided missile. It was shown that the maximum 55.3% reduction in lock-on range is possible for deformed nozzles with the high aspect ratio.

Evaluation of Gap Heat Transfer Model in ELESTRES for CANDU Fuel Element Under Normal Operating Conditions (CANDU형 핵연료봉의 정상상태 계산용 ELESTRES 코드내 간극 열전달 모델 평가)

  • Lee, Kang-Moon;Ohn, Myung-Yong;Lim, Hong-Sik;Park, Jong-Ho;Hwang, Son-Tae
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.344-357
    • /
    • 1995
  • The gap conductance between the fuel and the sheath depends strongly on the gap width and has a significant influence on the amount of initial stored energy. The modified Ross and Stoute gap conductance model in ELESTRES is based on a simplified thermal deformation model for steady-state fuel temperature calculations. A review on a series of experiments reveals that fuel pellets crack relocate, and are eccentrically positioned within the sheath rather than solid concentric cylinders. In this paper, the hue recently-proposed gap conductance models (offset gap model and relocated gap model) are described and are applied to calculate the fuel-sheath gap conductances under experimental conditions and normal operating conditions in CANDU reactors. The good agreement between the experimentally-inferred and calculated gap conductance values demonstrates that the modified Ross and Stoute model was implemented correctly in ELESTRES. The predictions of the modified Ross and Stoute model provide conservative values for gap heat transfer and fuel surface temperature compared to the offset gap and relocated gap models for a limiting power envelope.

  • PDF

Interleaving Phenomena of the North Pacific Intermediate Water in the Offshore Area of the Kuroshio

  • Yang, Sung-Kee;Lee, Byung-Gul
    • Journal of Environmental Science International
    • /
    • v.12 no.5
    • /
    • pp.521-527
    • /
    • 2003
  • To study the intruded phenomena of North Pacific Ocean around Boso peninsular, water property distribution in the adjacent seas to Japan is studied using the hydrographic data obtained by Japan Maritime Agency and Japan Fisheries Agency from 1973 to 1996, The scattering of water type in T-5 diagram is relatively small in the Kuroshio Region. Both the envelopes of saline side and of fresh side of the scattered data points shifts gradually from saline side to fresh side as the observation Line moves from southwest to northeast. In mixed water region, the scattering of water type increases rapidly as the observation line moves north; the envelope of fresh cold side moves towards fresh cold side much faster than that of saline side. This suggests that the water does not advect along the salinity minimum layer, but the salinity minimum layer can be understood as a boundary of two different waters aligned vertically, We defined the typical water masses as the Oyashio Water and the Kuroshio Water. The water mass below the salinity minimum layer may be created by isopycnal mixing of these two water masses with a fixed mixing rate. While the water mass above the salinity minimum cannot be created simply by isopycnal mixing. The salinity minimum layer may be eroded from upper side due to active minxing processes in the surface layer, while the water of the salinity minimum layer moves gradually southward. This appears to give an explanation why the thermosteric anomaly value at salinity minimun decereases towards south.

Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System (바닥공조 시스템이 적용된 사무공간의 거주후 성능평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Jung, Hae-Kwon;Choi, Sun-Kyu;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.