• Title/Summary/Keyword: Entry Length

Search Result 92, Processing Time 0.019 seconds

Characteristics of High-Speed Railway Tunnel Entry Compression Wave (고속철도 터널입구에서 형성되는 압축파의 특성에 관한 연구)

  • Kim, Heuy-Dong;Kim, Tae-Ho;Lee, Jong-Su;Kim, Dong-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.234-242
    • /
    • 1999
  • Flow phenomena such as the pressure transients Inside a high-speed railway tunnel and the Impulsive waves at the exit of the tunnel are closely associated with the characteristics of the entry compression wave, which is generated by a train entering the tunnel. Tunnel entrance hood may be an effective means for alleviating the Impulsive waves and pressure transients. The objective of the current work is to explore the effects of the train nose shape and the entrance hood on the characteristics of the entry compression wave. Numerical calculations using the method of characteristics were applied to one-dimensional, unsteady, compressible flow field with respect to high-speed railway/tunnel systems. Two types of the entrance hoods and various train nose shapes were employed to reveal their influences on the entry compression wave for a wide range of train speeds. The results showed that the entry compression wave length increases as the train nose becomes longer and the train speed becomes lower. The entry compression wave length in the tunnel with hood becomes longer than that of no hood. Maximum pressure gradient in the compression wavefront reduces by the entrance hood. The results of the current work provide useful data for the design of tunnel entrance hood.

A study on the development of the velocity and temperature fields in a laminar flow through an eccentric annular ducts (偏心된 二重圓管의 環狀部를 지니는 層流流動에서의 連度場 및 溫度場의 確立에 대한 硏究)

  • 이택식;이상산
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.861-869
    • /
    • 1986
  • A numerical study has been conducted on the development of the velocity and temperature fields in a laminar flow through an eccentric annular duct. A bipolar coordinates system is adopted, and a numerical program is developed to analyze 3-dimensional parabolic flow problems. In the analysis of the velocity field, the entrance length has been defined as the distance where the axial pressure gradient is greater than that of the developed velocity field by 5%. The dimensionless hydrodynamic entry length increases with increasing eccentricity. In the transverse flow fields, the reverse flow region along the wall due to the developing axial velocity near the entrance of the duct is found. In the analysis of the temperature field, the thermal entry length has been defined as the axial distance where the mean fluid temperature is 5% less than that of the developed temperature field. The dimensionless thermal entry length increases as eccentricity or Prandtl number increases. The overshoot of the mean Nusselt number over the developed value at the zero-temperature wall is encountered, and the rate of the overshoot increases with the increase of the eccentricity and Prandtl number.

Effect of Swirl Injector with Multi-Stage Tangential Entry on Acoustic Damping in Liquid Rocket Engine (액체로켓에서 다단 접선 유입구를 갖는 스월인젝터의 음향학적 감쇠기능)

  • ;;;;Bazarov, V. G.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.10
    • /
    • pp.71-79
    • /
    • 2006
  • Swirl injector with multi-stage tangential entry was analyzed to suppress high-frequency combustion instability in Liquid Rocket Engines. In order to analyze the effect of swirl injector as an acoustic absorber, swirl injector was regarded as a quarter-wave resonator and it's damping capacity is verified in atmospheric temperature. It has a finite mode of vibration and natural frequencies which can be tuned to the natural frequencies of a model combustion chamber. The interior air core shape of injector is more stable in the case of using the swirl injector with multi-stage entry than with single-stage entry. Also, when the swirl injector with multi-stage entry is used, tuned-injector length for unstable mode is well agreed with the calculated length. From the experimental data, it is proved that if the interior air core shape of swirl injector is stable, the fine tuned swirl injector can decrease the unstable mode of model chamber effectively and increase the damping rate.

The Effects of Operating Conditions and Injector Geometry on the Spray Characteristics of Swirl Injectors (스월 인젝터의 작동조건 및 인젝터 형상에 따른 분무특성)

  • Kim, D.J.;Im, J.H.;Han, P.G.;Yoon, Y.B.
    • Journal of ILASS-Korea
    • /
    • v.9 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • The flow characteristics of a swirl injector were investigated with the variation of the flow condition and geometric dimensions, such as orifice length for considering the viscous effect and tangential entry port area for considering the swirl intensity. The liquid film thickness strongly influencing on the formed drop size of the spray was measured using a new technique. The film thickness measurement technique proposed here, used the attenuation of fluorescence signal near the injector exit. The breakup length that is important for the flame location as well as the spray cone angle which influences on the ignition performance was measured using a backlit stroboscopic photography technique. From the experimental results, it is found that an increase in injection pressure decreased the film thickness and breakup length, and also enlarged the spray cone angle. A decrease in orifice length and tangential entry port area has a similar tendency of thinner film thickness, shorter breakup length and larger spray cone angle. In the present study, we proposed empirical models of the flow characteristics of the swirl injectors.

  • PDF

Effects of Inner Jet Injection on Particle Deposition in the Annular Modified Chemical Vapor Deposition Process Using Concentric Tubes (환상형원관을 사용하는 수정된 화학증착(MCVD)방법에서 내부 제트분사가 입자부착에 미치는 영향)

  • 최만수;박경순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.212-222
    • /
    • 1994
  • In the annular Modified Chemical Vapor Deposition process using two concentric tubes, the inner tube is heated to maintain high temperature gradients to have high thermophoretic force which can increase particle deposition efficiency. However, higher axial velocity in a narrow gap between inner and outer tubes can result in a longer tapered entry length. In the present paper, a new concept using an annular jet from the inner tube is presented and shown to significantly reduce the tapered entry length with maintaining high efficiency. Effects of a jet injection on heat transfer, fluid flow and particle deposition have been studied. Of particular interests are the effects of jet velocity, jet location and temperature on the deposition efficiency and tapered length . Torch heating effects from both the previous and present passes are included and the effect of surface radiation between inner and outer tubes is also considered.

Numerical study on the effect of three-dimensional unsteady tunnel entry flow characteristics on the aerodynamic performance of high-speed train (터널진입시 비정상 유동특성이 고속전철의 공력성능에 미치는 영향에 관한 수치해석적 연구)

  • 정수진;김태훈;성기안
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.596-606
    • /
    • 2002
  • The three-dimensional unsteady compressible Euler equation solver with ALE, CFD code, PAM-FLOW based on FEM method has been applied to analyze the flow field around the high speed train which is entering into a channel. From the present study, the pressure and flow transients were calculated and analyzed. The generation of compression wave was observed ahead of train and the high pressure in the gap between the train and the tunnel was also found due to the blockage effects. It was found that abrupt fluctuation in pressure exists in the region from train nose to shoulder of train corresponding to 10% of total length of train during tunnel entry. Computed time history of aerodynamic forces of train during tunnel entry show that drag coefficient rapidly rises and saturates at about non-dimensional time 0.31. The total increase of drag coefficient before and after tunnel entry is about 1.1%. Transient profile of lift force shows similar pattern to drag coefficient except abrupt drop after saturation and lift force in the tunnel increases 0.08% more than that before tunnel entry.

A Study on the Mininum Cost by Clock Routing Algorithm (클럭 라우팅 알고리즘을 이용한 최소비용에 관한 연구)

  • 우경환;이용희;이천희
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.943-946
    • /
    • 1999
  • In this paper, we present a new clock routing algorithm which minimizes total wirelength under any given path-length skew bound. The algorithm onstructs a bounded-skew tree(BST) in two steps:(ⅰ) a bottom-up phase to construct a binary tree of shortest-distance feasible regions which represent the loci of possible placements of clock entry points, and (ⅱ) a top-down phase to determine the exact locations of clock entry points. Experimental results show that our clock routing algorithm, named BST/DME, can produce a set of solutions with skew and wirelength trade-off.

  • PDF

Developing Design Guidelines for Rest Area Based on the Traffic Safety (교통안전을 고려한 고속도로 휴게소 설계기준 개발)

  • Lee, Hyun-Suk;Lee, Eui-Eun;Seo, Im-Ki;Park, Je-Jin
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.173-182
    • /
    • 2012
  • Entry and exits of the rest area are sections where designed speed can be rapidly change and also a weak traffic safety section. In addition, two tasks can be performed simultaneously at entry of the rest area, particularly searching for deceleration and parking spaces/parking sides etc. Thus, design criteria is required in order to procure the stability of accessed vehicle. In case of Korea, geometric structure design criteria of entry facilities, such as toll-gate, interchange, junction etc was established. However there are no presence in a detailed standards for geometric structure of the rest area which affiliated road facilities. In this study, Derive problems in regards to the entry of geometric structure of resting areas by utilizing a sight survey and an investigation research of traffic accidents. The survey was targeting 135 general service areas. After Classifying the design section of resting areas' entry as well as derive design elements on each section, a speed measurement by targeting entry of rest areas and car behavior surveys were performed, then each element's minimum standard was derived through the analyses. According to the speeds at the starting/end point of entrance connector road, the minimum length of the entrance connector road is decided as 40m using Slowing-down length formula and based on the driving pattern, the range of the junction setting angle of the entrance connector road is defined as $12^{\circ}{\sim}17^{\circ}$. Suggest improvement plans for existing rest areas that can be applied realistically. This should be corresponded to the standards of entry and exit of developed rest areas.

Study on Heat Transfer Characteristics for Single-phase Flow in Rectangular Microchannels (사각 마이크로 채널의 단상 유동 열전달 특성 연구)

  • Mun, Ji-Hyun;Kim, Seon-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.891-896
    • /
    • 2011
  • In this study, experiments were carried out to investigate the convective heat transfer characteristics of rectangular microchannels. The sample used in the experiments contained 20 rectangular microchannels in parallel. The channels had a hydraulic diameter of 700 ${\mu}m$. Distilled water was used as the working fluid. In the experiments, the Reynolds number ranged from 400 to 800, heat flux ranged from 35 to 85 kW/$m^2$, and the inlet fluid temperature was $20^{\circ}C$. As a result, the convective heat transfer coefficient increased upon increasing the Reynolds number and ranged from 4.6 to 6.4 kW/$m^2/^{\circ}C$ in the thermally fully developed region. Moreover, the higher the Reynolds number, the longer the thermal entry length in the rectangular microchannels. However, it was observed that a variable heat flux did not affect the thermal entry length. In conclusion, a correlation was proposed to indicate the heat transfer characteristics in a thermally fully developed region.

A Development of the Design Guidelines for Connecting Roads in Highway Rest Area (고속도로 휴게소 연결로 설계 기준 설정에 관한 연구)

  • Lee, Choulsoo;Won, Jaimu
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.143-154
    • /
    • 2013
  • PURPOSES: Design of approach roads of rest areas in highway has many drawbacks such as geometric design elements. There has been traffic accidents occured in these approach roads of rest areas. Thus, design criteria is required in order to protect accidents from being occurred. In case of Korea, geometric structure design criteria of entry facilities, such as toll-gate, interchange, junction etc was established. However there are no presence in a detailed standards for geometric structure of the rest area which affiliated road facilities. METHODS: In this study, analytic on accidents was carried out in regards to the entry of geometric structure of resting areas by utilizing a sight survey and an investigation research of traffic accidents. The survey was targeting 135 general service areas. Collisions with physical channelization and safety facilities occurred due to speeding, rapid entry, and etc at the entrance nose section. At the entrance connector roads, accidents caused by speeding, negligence, over-operation of handle of drivers were main reason of accidents. Discriminant analysis were conducted about geometric elements to distinguish influencing factors for traffic accidents. the lengths and access angles of the entrance connector roads were regarded as to have the high relation with traffic accidents. RESULTS: After classifying the design section of resting areas' entry as well as derive design elements on each section, a speed measurement by targeting entry of rest areas and car behavior surveys were performed, then each element's minimum standard was derived through the analyses. According to the speeds at the starting/end point of entrance connector road, the range of the junction setting angle of the entrance connector road is defined as $12^{\circ}{\sim}17^{\circ}$ and the connector length model was suggested. CONCLUSIONS: Suggest improvement plans for existing rest areas that can be applied realistically. This should be corresponded to the standards of entry and exit of developed rest areas.