• 제목/요약/키워드: Energy variation

검색결과 2,920건 처리시간 0.03초

소결조건의 변화에 따른 질화규소계 탄화규소질 탈황분사 슬러리 노즐의 제조 및 특성 (Fabrication and Characteristics of Silicon Nitride Bonded Silicon Carbide-based Slurry Nozzle for Desulfurization with Variation of Sintering Conditions)

  • 우상국;한인섭;서두원;이기성;홍기석;배강;임광현
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.201-207
    • /
    • 2002
  • 배가스 탈황 공정은 흡수제의 형태에 따라 습식과 건식, 반응생성물로부터 흡수제의 회수여부에 따라 재생법과 비재생법으로 분류할 수 있으며, 현재 전 세계적으로 상용화되고 있는 처리공정은 비재생 습식 석회석-석고 공정이 채택되어 전체 설치용량의 80% 이상을 점유하고 있다.(중략)

  • PDF

Model Development of Daily and Hourly Energy Load for Department Stores

  • Park Hwa-Choon;Lee Sung-Soo;Kim Dae-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.169-175
    • /
    • 2004
  • Case study was performed to analyze energy load for department stores and develop energy load model to be applied to a cogeneration system. Energy loads of 14 depart­ments were analyzed based on energy load sheets written by operators and energy load of one department store was measured through modem communication for a year. Energy load of department stores showed various trends depending on when they were opened or closed, or by hour, day and month. In this paper, the measurement was compared with the data in energy load sheets and resolved, and energy load model for a department store was built. It is important to use an accurate energy load model for an accurate feasibility study applying a cogeneration system to buildings.

대규모 태양열발전 기본설계 및 동특성 계산 (Basic Design and Dynamic Simulation of Large Scale Solar Thermal Power Plant)

  • 김종규;강용혁;김진수;윤환기;유창균;이상남
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.55-61
    • /
    • 2007
  • This paper describes the procedure and calculation results of basic design and transient variation of performance of 1 MWe large scale solar thermal power plant (STPP) by using the commercial software of THERMOFLEX and TRNSYS, respectively. In order to simulate the transient variation of STPP, the results of basic design are necessary. The design standard of the STPP is 1 MWe generation with solar only at high DNI condition and then 0.6 MWe output power for 1 hour using stored energy when the DNI becomes lower unable to operate normally. The results of basic design show the important design data of flow rates, water/steam conditions at each equipments and the estimated efficiency of STPP. In addition, dynamic simulation results of STPP are predicted and plotted for one year and three different days weather data of Daejeon.

A Supercapacitor Remaining Energy Control Method for Smoothing a Fluctuating Renewable Energy Power

  • Lee, Wujong;Cha, Hanju
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.146-154
    • /
    • 2015
  • This paper proposes a control method for maintaining the energy level for a supercapacitor energy storage system coupled with a wind generator to stabilize wind power output. Although wind power is green and clean energy source, disadvantage of the renewable energy output power is fluctuation. In order to mitigate the fluctuating output power, supercapacitor energy storage system (SCESS) and wind power simulator is developed. A remaining energy supercapacitor (RESC) control is introduced and analyzed to smooth for short-term fluctuating power and maintain the supercapacitor voltage within the designed operating range in the steady as well as transient state. When the average and fluctuating component of power increases instantaneously, the RESC compensates fluctuating power and the variation of fluctuating power is reduced 100% to 30% at 5kW power. Furthermore, supercapacitor voltage is maintained within the operating voltage range and near 50% of total energy. Feasibility of SCESS with RESC control is verified through simulation and experiment.

건물일체형 투명 모듈의 온도 변화에 따른 발전 특성 (Generation characteristics of transparent BIPV module according to temperature change)

  • 박경은;강기환;김현일;유권종;장대호;이문희;김준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.210-211
    • /
    • 2007
  • Amid booming PV(photovoltaic) industry, BIPV(Building Integrated PV) is one of the best fascinating PV application technologies. To apply PV in building, variable factors should be reflected such as installation position, shading, temperature effect and so on. Especially a temperature should be considered, for it affects both electrical efficiency of PV module and heating and cooling load in building. Transparent PV modules were designed as finished material for spandrels are presented in this paper. The temperature variation of the modules with and without air gap and insulation were compared and analyzed. The results showed that the module with air gap and insulation has a much larger temperature variation than another transparent module. The temperature of the module reached by 55degree C under vertical irradiance of lower 500$W/m^2$. And the temperature difference between these modules was about 15degree C. To analyze the output performance of module according to temperature variation, separate module was manufactured and measured by sun-simulator. The results showed that 1 degree temperature rise reduced about 0.45% of output power.

  • PDF

지하공간건설 시 해안인근 담수-해수 혼합대의 지화학적 진화 (Geochemical Evolution of Mixing Zone with Freshwater and Seawater near the Coast Area during Underground Space Construction)

  • 김지연;김병우;권장순;고용권
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권7호
    • /
    • pp.90-102
    • /
    • 2015
  • To understand the hyrogeochemical variation of bedrock aquifer during underground space construction, various graphical methods including multiple-component plots and chemical trends were used to estimate the mixing rate between seawater and freshwater and to investigate the evolution of water quality. The water chemistry and mixing rate between fresh and sea waters, which are generally localized in the construction area (MW-7, in land), shows typical characteristics of freshwater that doesn’t affect its validity as seawater intrusion. Especially, the water chemistry of a MW-4 (coastline) was classified as Na-Cl type, Na-HCO3 type, and Ca-Cl type due to the influence of the seawater intrusion. And hydrogeochemical and isotopic data show that local freshwater is subjected to geochemical processes, such as reverse ion-exchange. Throughout the Chadha’s diagrams, four different case histories with the temporal and spatial variation of groundwaters in the study area were proposed, which is recommended to interpret the hydrogeochemical reactions effectively.

태양열을 이용한 시설재배 지중변온가온의 토양 온도특성 연구(1) - 지중변온가온에 따른 깊이별 온도특성 - (Study on the Temperature Variation of Greenhouse Soil Warming using the Solar Energy(1) - Temperature Variation of Soil Depth by Soil Warming -)

  • 김진현;김태욱;나규동;김태수;성일중;정석현
    • Journal of Biosystems Engineering
    • /
    • 제34권3호
    • /
    • pp.190-196
    • /
    • 2009
  • The temperature of root zone is known as an important factor for the growth of crops and reduction of energy in greenhouse. The purpose of this study was to design the solar energy supply system to keep the optimum condition of root zone by soil warming. As a result of this study, soil warming compared with no warming changed on a large scale temperature rise effect by depth of soil. The greenhouse's inner temperature have an effect on the temperature of surface up to 15 cm, rised to about 1 hour after warming. In case of the temperature fluctuation, soil temperature was about $12^{\circ}C$ up to 15${\sim}$25 cm and it was $13.4^{\circ}C$ at greater depths. This results showed that the position of root zone was very different after 3 weeks of growth.

지하수 유동 영향에 따른 지하수 이용 열펌프 시스템의 대수층 온도 변화 예측 모델링 (Simulation of aquifer temperature variation in a groundwater source heat pump system with the effect of groundwater flow)

  • 심병완;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.701-704
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having influenced by groundwater movement, understanding of thermo hydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.00 1 are shaped circular, and the center is moved less than 5m to the groundwater flow direction in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF

외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구 (Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature)

  • 변재기;이규호;최영돈;신종근
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

수입 박류사료내 에너지 및 영양소 함량의 변이 (Variation in Energy and Nutrient Composition of Oilseed Meals from Different Countries)

  • 손아름
    • 한국가금학회지
    • /
    • 제47권2호
    • /
    • pp.107-114
    • /
    • 2020
  • This study was conducted to investigate the variation in nutrient composition of oilseed meals and to develop prediction equations for amino acid concentrations. Energy and nutrient contents were determined in a total of 1,380 feed ingredient samples including copra byproducts, corn distillers, dried grains with solubles, palm kernel byproducts, and soybean meal. The ingredient samples were imported to the Republic of Korea between 2006 and 2015. Data were analyzed using the MIXED procedure of SAS. The regression procedure of SAS was used to generate the prediction equation for the lysine concentration using the crude protein (CP) concentration as an independent variable. The concentrations of moisture, gross energy, CP, ether extract, crude fiber, ash, calcium, phosphorus, lysine, methionine, cysteine, and threonine in tested oilseed meals differed (P<0.05) depending on producing countries. The prediction equations for amino acid concentrations (% as-is basis) in the oilseed meals are: lysine = -1.08 + 0.080 × CP (root mean square error = 0.244, R2 = 0.924, and P<0.001); threonine = -0.297 + 0.044 × CP (root mean square error = 0.099, R2 = 0.958, and P<0.001). In conclusion, energy and nutrient compositions vary in the oilseed meals depending on the producing countries. Moreover, the crude protein concentration can be used as a suitable independent variable for estimating lysine and threonine concentrations in the oilseed meals.