• 제목/요약/키워드: Energy variation

검색결과 2,920건 처리시간 0.029초

VARIATION OF NEUTRON MODERATING POWER ON HDPE BY GAMMA RADIATION

  • Park, Kwang-June;Ju, June-Sik;Kang, Hee-Young;Shin, Hee-Sung;Kim, Ho-Dong
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.9-14
    • /
    • 2009
  • High density polyethylene (HDPE) is degraded due to a radiation-induced oxidation when it is used as a neutron moderator in a neutron counter for a nuclear material accounting of spent fuels. The HDPE exposed to the gamma-ray emitted from the fission products in a spent nuclear fuel results in a radiation-induced degradation which changes its original molecular structure to others. So a neutron moderating power variation of HDPE, irradiated by a gamma radiation, was investigated in this work. Five HDPE moderator structures were exposed to the gamma radiation emitted from a $^{60}Co$ source to a level of $10^5-10^9$ rad to compare their post-irradiation properties. As a result of the neutron measurement test with 5 irradiated HDPE structures and a neutron measuring system, it was confirmed that the neutron moderating power for the $10^5$ rad irradiated HDPE moderator revealed the largest decrease when the un-irradiated pure one was used as a reference. It implies that a neutron moderating power variation of HDPE is not directly proportional to the integrated gamma dose rate. To clarify the cause of these changes, some techniques such as a FTIR, an element analysis and a densitometry were employed. As a result of these analyses, it was confirmed that the molecular structure of the gamma irradiated HDPEs had partially changed to others, and the contents of hydrogen and oxygen had varied during the process of a radiation-induced degradation. The mechanism of these changes cannot be explained in detail at present, and thus need further study.

18650 Li-ion battery Module의 Cell-to-Cell 온도 편차 최소화를 위한 양방향 냉각에 대한 실험적 연구 (Experimental Study on Bi-directional Air Cooling System for 18650 Li-ion Battery Module to Minimize Cell-to-Cell Temperature Variation)

  • 장호선;박민규;전지환;박성수;김태우;박성진
    • 한국수소및신에너지학회논문집
    • /
    • 제28권4호
    • /
    • pp.407-418
    • /
    • 2017
  • Battery heat management is essential for high power and high energy battery system because it affects its performance, longevity, and safety. In this paper, we investigated the temperature of the 18650 Lithium Ion Battery Module used in a Energy Storage System (ESS) and the cooling method to minimize cell-to-cell temperature variation of battery module. For uniform temperature distribution within a battery module, the flow direction of the coolant in a battery module has been changed according to the time interval, and studied the effect of the cooling method on the temperature uniformity in a battery module which includes a number of battery cells. The experimental results show that bi-directional battery cooling method can effectively reduce the cell-to-cell temperature variation compared with the one-directional battery cooling. Furthermore, it is also found that bi-directional battery cooling can reduce the maximum temperature in a battery module.

가정용 열펌프 시스템의 정상냉방 운전조건에서 기준모델에 의한 잔차의 통계적 분석 (Statistical Analysis on Residuals from No-Fault Reference Models of a Residential Heat Pump System in Normal Cooling Operation)

  • 김민성;윤석호;백영진
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1351-1358
    • /
    • 2011
  • 열펌프의 고장감지 및 진단을 위하여 측정값에 대한 분석은 필수적이다. 열펌프의 고장감지는 열전대 등의 온도센서로 수행되는데, 재연성과 센서자체의 오차에 의해 시스템의 정상상태 측정값들은 통상 백색 노이즈의 형태로 존재한다. 고장감지 및 진단시스템을 구축하기 위하여 이상적인 정상상태를 정의하는 기준모델을 추출하게 되는데, 실제 측정값과 모델에 의한 기대값은 수학적 편차, 즉 잔차가 필연적으로 존재하게 된다. 이러한 잔차는 운전조건에 따라 변화하며, 다양한 불확실도를 포함한 확률분포를 갖게 된다. 본 연구에서는 온도센서를 활용하여 정상상태 진단을 수행하고 이를 기반으로 기준모델을 도출하였다. 이후 실측값과 기준모델과의 잔차를 통계적으로 분석하여 고장여부를 판단하는 경계값을 산출하였다. 본 분석에 의하여 열펌프의 고장감지 및 진단시스템의 개발을 위한 불확실도와 경계값을 통계적으로 계산함으로써 진단결과의 확률적 신뢰성을 보장할 수 있는 방법론을 제공하였다.

건물의 축열질량이 실내기온 변화에 미치는 영향 평가 (An Investigation into the Building's Thermal Mass Effect on the Variation of Indoor Temperature)

  • 천원기;전명석
    • 태양에너지
    • /
    • 제12권1호
    • /
    • pp.72-80
    • /
    • 1992
  • 본 연구에서는 건물의 축열 질량이 실내 온도의 변화에 미치는 영향을 조사하였다. 건물의 열적 성능 분석과 관련하여 사용된 기법은 미국 신에너지 연구소에서 개발된 PSTAR(Primary and Secondary Terms Analysis and Ronormalization)방법이다. 얻어진 결과는 축열질량과 관련하여 매우 대조적인 두 경우를 대변하는데, 특히 실내의 열환경과 건물의 전체적인 열적 성능에 미치는 영향을 잘 보여주고 있다. 재표준화된 모델을 이용한 월별 냉난방 부하와 이의 최대 요구치는 건물에 있어서 냉난방 시스템의 설계에 유용한 자료를 제시하고 있다.

  • PDF

무기력(無氣力) 및 피로(疲勞)에 관(關)한 문헌적(文獻的) 고찰(考察) -(동서의학적(東西醫學的) 비교고찰(比較考察), 원인(原因).증상(症狀)을 중심(中心)으로)- (Review of Literature on Languor and fatigue)

  • 오태환;정승기;이형구
    • 대한한방내과학회지
    • /
    • 제11권2호
    • /
    • pp.80-93
    • /
    • 1990
  • Review of Literature on Languor and fatigue. According to comparative studies of Oriental and Western medical Literature on the Languor and fatigue on causes and symptom, flowing results were obtained. 1. Common etiologies of the Languor and fatigue in Western medicine are firstly exhaustion of energy, secondly variation of control center-neurotic and body fluid control-, thirdly variation of a living body physico chemical state, forthly production of middle metabolic product, fifthly psychological instability. 2. The expression of the Languor and fatigue in Oriental medicine are consumption, dificiency of vital energy(氣虛), illness caused by overexertion and dificiency of essence of life(精虛). The caure of the Languor and fatigue are dificiency in spleen and stomach(脾胃虛弱), dificiency of both the lung and kidney(肺腎兩虛), the six excessive(六淫), irregular life and excessive mental labor. 3. The symptomes of the Languor and fatigue in western medicine are systemic feeling of fatigue, dislike of work, Dizziness, general fatigue, anorexia, painful body, nerveous prostration. anxiety and decrese of energy, and in oriental medicine dificiency of vital energy, general pain, sinking of vital energy(氣虛下階) in adequate nutrition, confusion and slow speaking.

  • PDF

태양광 기반의 가변속 하이브리드 시스템을 위한 직류 전압 제어 (DC-Voltage Regulation for Solar-Variable Speed Hybrid System)

  • 니이테게카 기디언;이경규;최재호;송유진
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.231-237
    • /
    • 2016
  • Recently, the interest in DC systems to achieve more efficient connection with renewable energy sources, energy storage systems, and DC loads has been growing extensively. DC systems are more advantageous than AC systems because of their low conversion losses. However, the DC-link voltage is variable during operation because of different random effects. This study focuses on DC voltage stabilization applied in stand-alone DC microgrids by means of voltage ranges, power management, and coordination scheme. The quality and stability of the entire system are improved by keeping the voltage within acceptable limits. In terms of optimized control, the maximum power should be tracked from renewable resources during different operating modes of the system. The ESS and VSDG cover the power shortage after all available renewable energy is consumed. Keeping the state of charge of the ESS within the allowed bands is the key role of the control system. Load shedding or power generation curtailment should automatically occur if the maximum tolerable voltage variation is exceeded. PSIM-based simulation results are presented to evaluate the performance of the proposed control measures.

Variation of Energy Consumption in Barracks through Simulation by Year of Completion

  • Choi, Doo-Sung;Jeon, Hung-Chan;Cho, Kyun-Hyong;Yoo, Jeong-Seong
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze & suggest the variation of energy consumption consequent on thermal insulation performance strengthening from early 2000s when modernization of barracks began until the present targeting a large barracks. Method: To carry out this research, this study surveyed the standard of thermal insulation by year, which is being applied to a barracks by conducting literature search, and selected the standard model for a barracks. Also, this study analyzed energy consumption by year & region by performing simulation(ECO2)of the selected standard model. Result: As a result, it was analyzed that in case of a building which was completed in 2015, the energy consumption for air-conditioning & heating, lighting, and hot water supply over the year 2000 reduced by 11% on the average in central district, 10% on the average in southern district, and 17% on the average in Jeju, respectively.

3차원 교차 주름판 내 유동의 불안정성 및 자활 진동 (Instability and Self-Sustained Oscillation of the Flow between Three-Dimensionally Cross-corrugated Plates)

  • 이승엽;최영돈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.679-682
    • /
    • 2002
  • Energy dissipations in a general PHE flow are the compounded effects of the piled corrugate geometries and its wall pressure and temperature distributions. In addition, although the exchangers are substantial pieces of engineering equipment, they are composed of a very large number of nominally identical and small geometrical elements. In the present numerical study, the three-dimensionally complicated energy dissipation fields and those wall-shape-induced flow destabilization are investigated in the cross-corrugated passages, which result in high energy transports with comparatively low pressure drop. We revealed the critical conditions as $Re=157.3 for the wall-shape-induced flow destabilization in a general PHE element by initial value method, or shooting method, and compare its value to that of analytical solution of plane Poiseille flow, two-dimensional grooved flow and so on. We also observed the detailed variation of flow field and energy transportation with changes in time and flow variables such as Reynolds number. Lastly, we considered the flow natural frequency, or Strouhal number, with variation of hydrodynamic conditions for the best use of active control, such as forced mass flow rate pulsative flow, to enhance energy transportation.

  • PDF

PV모듈 발전성능 비교시험과 계측편차 요인 분석 (Analysis of Comparison Test and Measurement Error Factor for I - V Performance of Photovoltaic Module)

  • 강기환;김경수;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.70-75
    • /
    • 2009
  • In this experiment, we did sampling 6 kinds of photovoltaic modules and analyzed the discrepancy of measurement results between l laboratory and 4 PV makers to have performance repeatability at Standard Test Condition(STC) condition. From the KIER's results, Korea's standard test laboratory, other laboratory showed -10% measurement variation. The causes came from correction of reference cell, test condition and the state of skill. Form the comparison test, we analyzed the problems. But three PV maker reduced measurement variation, other one PV maker and one test laboratory didn't improve the problems of correction of reference cell, test condition and the state of skill. Also, High Efficiency Module had a big discrepancy of -10.0$\sim$-6.2% among 3 laboratories which have a less than 10msec light pulse duration time. This made low spectrum response speed so the Fill Factor decreased maximum output power under 10msec light pulse duration time

연천 지역 성인의 계절별 영양소 및 식품섭취 비교 연구 (Seasonal Variation of Dietary Intake and Quality from 24 Hour Recall Survey in Adults Living in Yeonchon Area)

  • 백희영;송윤주
    • 한국식품영양과학회지
    • /
    • 제27권4호
    • /
    • pp.775-784
    • /
    • 1998
  • This study was conduced to investigate the seasonal variation of dietary intake and quality obtained by 24 hour recall method in Korean adults living in rural area. The mean daily intakes of 4 seasons were 1,692kcal for energy, 63g(14.8% of energy) for protein, 30g(15.7% of energy) for fat, 257g(60.7% of energy) for carbohydrate. Mean daily intakes were significantly highest in winter for most of the nutrients, and lower in summer for energy, fat, calcium, iron. Mena adequacy ratio(MAR), an index of overall nutritional quality was 0.65 in winter, 0.67 in spring, 0.65 in summer and 0.72 in autumn and nutrient adequacy ratio(NAR) was significantly different fro vitamin C agmong different seasons. Subjects consumed usually 15.3 different foods in winter, 14.5 in summer, 13.9 in spring and 13.7 in autumn. The number of food consumed was positively correlated with intake of most nutrients, especially in autumn. For variety among the five major food groups(grain, meat, dairy, fruit, vegetable) with a dietary diversity scores(DDS) calculated, the average socre of DDS was 3 in all seasons and omitted food groups were usually dariy and fruit. In conclusion, dietary intake and quality of Korean adults were different according to seasons.

  • PDF