• 제목/요약/키워드: Energy performance analysis

검색결과 4,219건 처리시간 0.063초

태양광에너지 중심의 신재생에너지 기술경제학 모델링 연구 (The technical-economic study of solar PV and renewable energy)

  • 이문수;이민진;이영희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.136.1-136.1
    • /
    • 2011
  • An energy modeling analysis method currently has been considered as a new approach for energy policy research, because the importance of renewable energy use has been emphasized more and more. This study used RETScreen model as a clean energy decision making methodology for adaptation to climate change and elimination of various pollutions. This modeling method includes five step standard analysis; energy model, cost analysis, GHG analysis, financial analysis, and sensitivity & risk analysis and it also assesses both conventional and modern energy sources and technologies. This methodology for the photovoltaic(PV) energy modeling is used to evaluate the energy production, financial performance and GHG emissions reduction of photovoltaic projects. In addition, the PV application systems are classified into three basic applications; On-grid system, Off-grid system and water pumping system. This study assesses the renewable energy techno-economic modeling method with the feasibility analysis result of 10 MW PV power plant in Abu Dhabi in United Arab Emirates. Furthermore this study stresses the importance of renewable energy model research by applying to domestic PV power plant which is now in preparation.

  • PDF

Influence of design modification of control rod assembly for Prototype Generation IV Sodium-cooled Fast Reactor on drop performance

  • Son, Jin Gwan;Lee, Jae Han;Kim, Hoe Woong;Kim, Sung Kyun;Kim, Jong Bum
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.922-929
    • /
    • 2019
  • This paper presents the drop performance test of the control rod assembly which is one of the main components strongly related to the safety of the prototype generation IV sodium-cooled fast reactor. To investigate the drop performance, a real-sized control rod assembly that was recently modified based on the drop analysis results was newly fabricated, and several free drop tests under different flow rate conditions were carried out. Then the results were compared with those obtained from the previous tests conducted on the conceptually designed control rod assembly to demonstrate the improvement in performance. Moreover, the drop performance tests under several types and magnitudes of seismic loadings were also conducted to investigate the effect of the seismic loading on the drop performance of the modified control rod assembly. The results showed that the effects of the type and magnitude of the seismic loading on the drop performance of the modified control rod assembly were not significant. Also, the drop time requirement was successfully satisfied, even under the seismic loading conditions.

Performance Prediction of Impulse Turbine System in Various Operating Conditions

  • 현범수
    • 한국해양공학회지
    • /
    • 제21권5호
    • /
    • pp.9-17
    • /
    • 2007
  • This paper deals with the design and analysis of a 250kW class impulse turbine for wave energy conversion. Numerical analysis was performed using FLUENT. The size and the performance of a turbine required to provide a certain power can be estimated using a series of performance charts built through the present study. Temporal and spatial variations of flaw fields were also considered and compared with those of uniform inflow. It was concluded that a simple steady-flow analysis using performance charts still provided a practical and useful way to predict the design and performance of turbines.

군사시설 내 지열 히트펌프 시스템 적용에 따른 에너지 성능과 비용 절감 효과 평가 (Energy Performance and Cost Assessment for Implementing GroundSource Heat Pump System in Military Building)

  • 손병후;조경주;조동우
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.45-57
    • /
    • 2022
  • The Ministry of National Defense of the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of military facilities and to promote green growth policy in military sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. This paper analyzed energy performance and energy cost on the conventional heating and cooling system (baseline scenario) and three different alternative scenarios (ALT 1, ALT 2 and ALT 3) applied in a hypothetical military building. A building modeling and simulation software (DesignBuilder V6.1) with EnergyPlus calculation engine was used to calculate the energy consumption for each scenario. Overall, when the GSHPs are applied to both space airconditioning and domestic hot water (DHW) production, Alt-2 and Alt-3, the amount of energy consumption for target building can be greatly reduced. In addition, when the building envelope performance is increased like Alt-3, the energy consumption can be further reduced. The annual energy cost analysis showed that the baseline was approximately 161 million KRW, while Alt-3 was approximately 33 million KRW. Therefore, it was analyzed that the initial construction cost increase could be recovered within about 6.7 years for ALT 3. The results of this study can help decision-makers to determine the optimal strategy for implementing GSHP systems in military buildings through energy performance and initial construction cost assessment.

계통운영시스템 계통해석 프로그램 검증 방안에 관한 연구 (A Study on the Validation Methodology of Network Analysis Applications in Energy Management Systems)

  • 조윤성
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.27-36
    • /
    • 2014
  • Network analysis applications in energy management systems play a key role in the economic and reliable operation of power systems. In order to provide operators with useful network information, the accurate results of topology processing, state estimation, power flow, and contingency analysis must be simulated. This paper proposes a validation methodology of network analysis applications in energy management systems. The energy management systems was checked to ensure that it meets the originally specified functions based on the proposed methodology. In addition, the performance of state estimation is evaluated with the reference of the proposed methodology. The proposed methodology is being conducted by energy management systems and the Korean power systems have been utilized for the test systems.

지역에 따른 주거용 건물에너지효율등급 분석 연구 (A Study on the Analysis of Building Energy Rating considering the Region)

  • 안병립;김지훈;김지연;장철용
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.53-58
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy can be expected to reduce energy demand more than other section. To do this, the Building Energy Rating System is applied and implemented in Apartment houses on Jeju, South and Central region. This system calculates into energy saving rate, and certifies the building energy rating. This study evaluates the energy saving rate and rating and compares the difference in energy savings considering to each region and the thermal performance of the window. In result, the standard of the assessment house which is applied to the build energy rating system is demanded to distinguish the thermal performance of window according to regional variation.

창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석 (A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size)

  • 김성범;이수열;김동윤;최원기
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

SMART-P PRHRS Performance Analysis

  • Lee, Seong-Wook;Chung, Young-Jong;Kim, Hee-Cheol
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2005년도 춘계학술발표회
    • /
    • pp.1241-1242
    • /
    • 2005
  • PDF