• Title/Summary/Keyword: Energy meter

Search Result 362, Processing Time 0.027 seconds

Parameter Focusing on the Topoisomerase I-inhibition Activities of 1-(2-furyl)-3-phenylpropenone Derivatives (1-(2-furyl)-3-phenylpropenone 유도체의 DNA Topoisomerase I 저해활성에 대한 parameter focusing)

  • 명평근;최수라;성낙도
    • YAKHAK HOEJI
    • /
    • v.44 no.4
    • /
    • pp.358-361
    • /
    • 2000
  • Parameter focusing on the DNA topoisomerase-Iinhibition with X-substituted phenyl substituents in 1-(2-furyl)-3-phenylpropenone derivatives as inhibition material were analyzed. From the basis on the results the inhibition on DNA topoisomerase I suggested that the inhibition activities of X-substituted phenyl substitutents would depend largely on the net charge of $\beta$-carbon atom, LUMO energy (e.v.) and STERIMOL parameter B$_{5}$ (width) of X. Among them, non-substituent (X=H), 1 and 2,2-dichloro substituent, 4 showed the highest DNA topoisomerase-I inhibition activity.y.

  • PDF

Trap Level Study of Alq3 for OLED with Debye Dielectric Relaxation (Debye 이론을 이용한 유기 EL용 Alq3계 재료의 Trap Level 측정)

  • Jeong, Yong-Seok;Jeong, Yeon-Tae;Kim, Jong-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.668-672
    • /
    • 2004
  • Upon Debye's dielectric relaxation theory, we tried simple determination method of trap level in organic EL materials. From dielectric measurements in the 20 Hz - 1 MHz frequency range and in the 150 K - 320K temperature range, the depth of traps in Alq$_3$ filled with remaining electrons was determinated. Comparing to other determination techniques like TSL, or TL, the apparatus all we need is just simple LCR meter, thermometer and cooling method(liquid nitrogen). The mean activation energy is about 0.20 eV. It is in good agreement with previous determinations by other techniques like TSL. This results consolidate the validity of Burrow's transport mechanism model. Further intensified experiment with UV light on the dielectric absorption(Photodipolair effect) was nevertheless disturbed by the photoconductivity component.

Application of Demand Controller for Summer Peak Demand Shaving and Valuation of its Economical Efficiency (하계최대부하 억제를 위한 디맨드 콘트롤러 적용사례 및 경제성 평가)

  • Kang, W.G.;Lee, G.W.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.720-723
    • /
    • 1996
  • The recent summer power peak crisis has been caused by excessive use of cooling loads at daily peak time in summer. The yearly load shape of KEPCO has gradually became very steep valley. Under this situation, more efficient DSM(Demand Side Management) tools are fully required for summer peak clipping and shaving. In this paper, the KEPCO's Jeju-Do model project for DSM, especially for Demand Controller, is presented. Demand Controller was evaluated to have the very high economical efficiency against the investment in equipment, as compared with another DSM tools. There were some serious problem to apply Demand Controller to many customers in the aspect to synchronization with KEPCO's watthour meter. But these problems have solved by Keyin's new Demand Controller using vision algorithm.

  • PDF

Analysis of Electrical Characteristics for Single Crystalline and Poly-crystalline Solar Cell (단결정, 다결정 실리콘 태양전지의 전기적 특성 분석)

  • Hong, Chang-Woo;Choi, Yong-Sung;Lee, Kyung-Sup;Cho, Soo-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.9
    • /
    • pp.744-749
    • /
    • 2011
  • Recently, annual usage of energy is dramatically increasing because industrialization is going faster and more electricity is needed due to various electronic devices. This study focused on the performance characteristics of solar cell using the impedance technique. The experiment measured an impedance according to frequency's from 2 mHz until 1 MHz. It could know that the impedance was decreased according to the frequency increases in solar cell. The imaginary part was changed from capacitance component to inductance component.

Basic Experimental Study on Room Lighting Effects using Artificial Light Source (인공 광원을 이용한 실내 조명 효과에 대한 기초 실험 연구)

  • Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.29-33
    • /
    • 2011
  • This study is performed to investigate the effect of the artificial light for room lightening. To do that, the experiments were done using the black room with 1m3 and performed to show the effect of the length between the room and light source and light intensities as LUX. The LUX of 18 sites in the room was measured using LUX meter. The length between the room and the light source was chosen as 500mm, 1000mm, and 1500mm and the light intensities was 3 levels. The results were shown the distinct difference between the part directly projected through the light path and non-directly projected. So, the light delivery path have to be modified for next step research. The results were very sensitive for the part directly projected through the light path. This study showed the basic results for room lightening using light source to simulate the solar lightening and was worth in a strict sense as fundamental study.

  • PDF

Design and Building of Flow-rate Measurement Apparatus for Compressible Fluid (압축성유체 유량계측장치 설계 및 제작)

  • Ji, S.W.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.10 no.4
    • /
    • pp.29-33
    • /
    • 2013
  • Pneumatic system is widely applied in various industry because it have a many advantage(low cost, high safety, etc..). For design of pneumatic system, accurate flow measurement is required. In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Therefore, it can be measured for flow-rate using pressure response of isothermal chamber. As a result, this apparatus can be measured for sonic conductance and critical pressure ratio of pneumatic components and it required less time and energy than conventional flow meter. The effectiveness of the designed apparatus is proved by experimental result.

소수력 발전에 대하여

    • Journal of the Korean Professional Engineers Association
    • /
    • v.15 no.1
    • /
    • pp.32-35
    • /
    • 1982
  • The sudden shock of repeated oil crisis and the subsequent violent increases in petroleum prices have given rise to an intensive worldwide effort to develop alternate sources of clean energy. Against this background, a great deal of attention has recently come to be focused on mini-scale hydroelectric power turbine generation. There is now a strong demand for the development of a hydroelectric generator suitable for generating power on a small scale and copable of overcoming the high per kilowatt cost of conventional one's then Francis turbine. Hence was accordingly developed the "Cross flowturbine generator" of 1000kw and less, which we call. This mimi-scale water turbine is reliably and easily handled and also can be economicaly manufactored in a range with effective head of over 3meter's a flow rate of minimum 30 liter per sec and an output of below 1000kw good's.kw good's.

  • PDF

Tractor Performance Instrumentation System

  • Wan Ismail, Wan Ishak;Yahya, Azmi;Bardaie, Mohd. Zohadie
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.569-581
    • /
    • 1996
  • A microcomputer -based data acquistion system was designed and developed at Michigan State University , USA to conduct field data studies. The system designed for the research carried out used an Apple IIe microcomputer for collecting data on-board the tractor. An AII3 Analog to Digital (A/D_ convertor was chosen to interface each analog signal to the microcomputer. A commercially available Dj TPM II was employed to display information such as an engine speed, ground speed, percent drive wheel slip , distance travelled and area covered per hour. The frequency output from the radar unit was channeled through a frequency to voltage (F/V) convertor , so that AII3 Analog to Digital (A/D) convertor could read it. The fuel consumption was measured using on EMCO pdp-1 fuel flow meter attached to the engine fuel line. The draft of the tillage and other drag equipment was determined using strain gages attached to the drawbar of the tractor. The system was developed to collect the draft and fuel requirements for various farm equipment different kind of soils.

  • PDF

A Study on the development and calibration method of a modular internal resistance meter to improve the safety of reusable batteries

  • Mi-Jin Choi;Sang-Bum Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.228-235
    • /
    • 2024
  • Battery use is increasing worldwide to achieve carbon neutrality and improve energy efficiency, but batteries are a finite resource and their application is determined by capacity and specifications. Battery performance deteriorates as the number of uses increases. A certain level of battery performance degradation has become an issue in the field of reuse and recycling, and various studies are being conducted on reuse to solve power shortages. Waste batteries from electric vehicles are suitable for building ESS based on reusable batteries, and for stable use, technical skills are needed to accurately predict battery life and determine status information. Predicting battery life and determining status information are difficult due to non-linearity due to internal structure or chemical changes. In this paper, we manufactured a modular internal resistance measuring device and compared the measured values with Hioki equipment to minimize the error rate through a correction method. As a result of testing Hioki equipment and modular measuring instruments to ensure efficiency and safety based on reusable batteries, an accuracy of over 95% was confirmed.

Effects of Different Exercise Intensities on GLUT-4 and GRP-78 Protein Expression in Soleus Muscle of Streptozotocin-Induced Diabetic Rats with Caffeine Oral Administration (카페인 경구투여가 운동강도 차이에 따른 당뇨유발 흰쥐 가자미근의 GLUT4 및 GRP78 단백질 발현에 미치는 영향)

  • Yoon, Jae-Suk;Yoon, Jin-Hwan
    • Journal of Life Science
    • /
    • v.14 no.5
    • /
    • pp.741-746
    • /
    • 2004
  • This study investigated the response of GLUT-4 and GRP-78 protein expression in soleus muscle of Streptozotocin-induced diabetic rats with caffeine oral administration by imposing different exercise intensities. Rats were randomly divided into 5 groups (n=6 in each group): diabetic group (D), diabetic-caffeine group (DC), diabetic-caffeine group with low intensity exercise (DCL), diabetic-caffeine group with moderate intensity exercise (DCM) and diabetic-caffeine group with high intensity exercise (DCH). The rats in DCL, DCM and DCH groups were exercised acutely by treadmill running for 8 meter/m, 16 meter/m and 25 meter/m, respectively. Little difference in GLUT-4 protein expression was shown in DC and DCL compared to D. GLUT-4 protein expression was decreased in DCM and increased in DCH was observed. GRP-78 protein expressions in DCL, DCM and DCH were little lower than that of D. An increase in GRP-78 protein was observed in DC. Improved insulin sensitivity with acute high intensity exercise gives the rats important therapy that lowers insulin requirement. This improvement of insulin sensitivity for glucose transport in skeletal muscle results from translocation of the GLUT-4 protein from the endoplasmic reticilum to the cell surface and increase in total quantity of GLUT-4 protein. It is not clear what mechanism reduced GRP-78 protein level in exercise group. It is merely conjectured that caffeine-induced lipolysis provided cells with energy in abundance and this relieved stress which cells are subjected to receive when performing exercise.