• Title/Summary/Keyword: Energy linearity

Search Result 251, Processing Time 0.03 seconds

A Study of the Thermoluminescent Properties of Korean Natural Quartz for Possible Use in Gamma-ray Dosimetry

  • Lee, Hee-Yong;Kim, Hi-Gyu;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.229-239
    • /
    • 1970
  • Various thermoluminescent properties of Korean natural quartz for possible use in ${\gamma}$-ray dosimetry has been studied. If the heating is exactly linear, ${\gamma}$-irradiated radiation sensitive (type 1) $\alpha$-quartz can yield a glow curve of single peak, hence glow peak height could be taken as a ${\gamma}$-dose for its dosimetry. Quartz crystal dosimeter exhibited the linearity of thermoluminescent intensity in the range from about 2$\times$10$^{3}$R to 2$\times$10$^{6}$ R, and also had an advantage of low fading because of the high peak temperature (300$\pm$4$0^{\circ}C$). The pulverized quartz sample having the grain size of 0.3<ø<0.9mm showed the linearity of T. L. intensity in the range from 50R to 2$\times$10$^3$R. Therapeutic application of the pulverized sample on the correct measurement of the absorbed dose in a body region of a cancer patient seems to be successful.

  • PDF

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Fuzzy Control with Feedforward Compensator of Superheat in a Variable Speed Refrigeration System

  • Hua, Li;Lee, Dong-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.252-262
    • /
    • 2007
  • In this paper, we suggest fuzzy control with feedforward compensator of superheat to progress both energy saving and coefficient of performance(COP) in a variable speed refrigeration system. The capacity and superheat are controlled simultaneously and independently by an inverter and an electronic expansion valve respectively for saving energy and improving COP in the system. By adopting the fuzzy control. the controller design for the capacity and superheat is possible without depending on a dynamic model of the system. Moreover, the feedforward compensator of the superheat can eliminate influence of the interfering loop between capacity and superheat. Some experiments are conducted to design the appropriate fuzzy controller by an iteration manner. The results show that the proposed fuzzy controller with the compensator can establish good control performances for the complicated refrigeration system with inherent strong non-linearity.

Effect of DP Finishing Conditions on the Mechanical Properties and Hand of Cotton Fabrics (DP 가공조건이 면직물의 역학적 성질과 태에 미치는 영향)

  • 신윤숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.3
    • /
    • pp.440-447
    • /
    • 2000
  • The effects of DP finishing conditions including process technique and finishing agent on the mechanical properties and hand of cotton fabrics were investigated. 100% cotton fabrics were treated with NMA/DMDHEU and NMA/YF using wet-fixation and steam-fixation process. For comparison, conventional pad-dry-cure process was used with DMDHEU. After DP finishing, tensile and compressional resilience increased and bending hysteresis decreased, resulting in the improvement of dimensional stability of cotton fabric. WF and SF process rendered fabrics better shear properties, tensile energy, and compressional linearity and energy than PDC process. However, SF process produced fabrics with higher geometrical roughness than WF process. After DP finishing, primary hand values except Koshi increased, resulting in the increase of total hand value of cotton fabric.

  • PDF

A Study on the Development of Nuclear Radiation Detector with Silicon PIN Photodiode (실리콘 포토다이오드를 이용한 방사선 검출기 개발에 관한 연구)

  • Yi, Un-K.;Kim, Jung-S.;Sohn, Chang-H.;Baek, Kwang-R.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.754-756
    • /
    • 1999
  • In this paper, we have developed a high-sensitivity SNRD(Semiconductor Nuclear Radiation Detector) using silicon PIN photodiode. The SNRD is constructed with silicon PIN photodiode(S3590-05), preamplifier and shaping amplifier. To show the effectiveness of SNRD, nuclear radiation experiments are conducted with $\gamma$-ray Ba-133, Cs-137 and Co-60. The SNRD is different in characteristics of the energy spectrum to scintillation detectors. However, the SNRD have a good linearity on $\gamma$-ray energy and activity. The results of this paper can be applied to electronic personal dosimeter.

  • PDF

A Study on the Fabrication and Detection of Cd$_{80}$ Zn$_{20}$Te Gamma-ray detector with MIM Structure (Cd$_{80}$ Zn$_{20}$Te를 사용한 MIM 구조의 감마선 탐지 소자 제작 및 탐지 특성에 관한 연구)

  • 최명진;왕진석
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.4
    • /
    • pp.47-53
    • /
    • 1997
  • We fabricated gamma radiation detector using high resistive p-Cd$_{80}$Zn$_{20}$Te grown by high pressure bridgman method and forming au thin film electrode by chemically electroless deposition method. The device of Au/Cd$_{80}$Zn$_{20}$Te/Au is a typical MIM structure. The characteristic of current-voltage showed good linearity to 3kV/cm but it depend on the square of electric field over 3kV/cm. As the results of rutherford backscattering spectroscope(RBS) and auger spectroscope on the Au/Cd$_{80}$Zn$_{20}$Te, Au penetrated to the surface of Cd$_{80}$Zn$_{20}$Te detector absorbed slightly high energy radiation like a few hundred keV and showed good performance to detect low energy gamma ray.mma ray.

  • PDF

Characteristics of Plastic Scintillators Fabricated by a Polymerization Reaction

  • Lee, Cheol Ho;Son, Jaebum;Kim, Tae-Hoon;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.592-597
    • /
    • 2017
  • Three plastic scintillators of 4.5 cm diameter and 2.5-cm length were fabricated for comparison with commercial plastic scintillators using polymerization of the styrene monomer 2.5-diphenyloxazole (PPO) and 1,4-bis benzene (POPOP). Their maximum emission wavelengths were determined at 426.06 nm, 426.06 nm, and 425.00 nm with a standard error of 0.2% using a Varian spectrophotometer (Agilent, Santa Clara, CA, USA). Compton edge spectra were measured using three gamma ray sources [i.e., cesium 137 ($^{137}Cs$), sodium 22 ($^{22}Na$), and cobalt 60 ($^{60}Co$)]. Energy was calibrated by analyzing the Compton edge spectra. The fabricated scintillators possessed more than 99.7% energy linearity. Light output was comparable to that of the BC-408 scintillator (Saint-Gobain, Paris, France). The fabricated scintillators showed a light output of approximately 59-64% of that of the BC-408 scintillator.

A scintillation detector configuration for pulse shape analysis

  • Van Chuan, Phan;Hoa, Nguyen Duc;Hai, Nguyen Xuan;Anh, Nguyen Ngoc;Dien, Nguyen Nhi;Khang, Pham Dinh
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1426-1432
    • /
    • 2018
  • This paper presents a neutron detector configuration using EJ-301 scintillation liquid, a R9420 photo-multiplier and a homemade preamplifier. The detector qualities which include the energy linearity, efficiency response and neutron/gamma discrimination are guaranteed for neutron detection in the energy range from 0 to 3000 keVee. Regarding the neutron/gamma discrimination capability, four pulse shape discrimination (PSD) methods which are the threshold crossing time (TCT), pulse gradient analysis (PGA), charge comparison (CC) and correlation pattern recognition (CPR), were evaluated and discussed; among of these, the CPR method provides the best neutron/gamma discrimination.

Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode (실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현)

  • 이운근;백광렬;권석근
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.4
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.