• 제목/요약/키워드: Energy fluxes

검색결과 249건 처리시간 0.023초

파랑을 이용한 부유식 직접 구동 터빈의 설계 (Design of Floating Type Wave Energy Convertor with Direct Drive Turbine)

  • 최현준;최종웅;김창구;이영호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.165.2-165.2
    • /
    • 2011
  • Dye to recent development such as increasing price of fossil fuels and energy offers such a solution. Wave energy supplies. Weve energy offers such a solution. Wave energy is the most consistent of all the intermittent renewable energy sources. In addition to this, very large energy fluxes occur in the ocean waves and by using appropriate wave energy converters the energy can be harnessed. The present study looks at utilizing a direct drive turbine of cross flow type to extract energy from ocean waves indirectly. This novel design incorporates a turbine in an enclosed in a closed tank. utilizing the energy generated from sloshing.

  • PDF

APPLICATION OF REMOTE SENSING IMAGERY ON THE ESTIMATE OF EVAPOTRANSPIRATION OVER PADDY FIELD

  • Chang, Tzu-Yin;Chien, Tzu-Chieh;Liou, Yuei-An
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.752-755
    • /
    • 2006
  • Evaportranspiration is an important factor in hydrology cycle. Traditionally, it is measured by using basin or empirical formula with meteorology data, while it does not represent the evaportranspiration over a regional area. With the advent of improved remote sensing technology, it becomes a surface parameter of research interest in the field of remote sensing. Airborne and satellite imagery are utilized in this study. The high resolution airborne images include visible, near infrared, and thermal infrared bands and the satellite images are acquired by MODIS. Surface heat fluxes such as latent heat flux and sensible heat flux are estimate by using airborne and satellite images with surface meteorological measurements. We develop a new method to estimate the evaportranspiration over the rice paddy. The surface heat fluxes are initialized with a surface energy balance concept and iterated for convergent solution with atmospheric correct functions associated with aerodynamic resistance of heat transport. Furthermore, we redistribute the total net energy into sensible heat and latent heat fluxes. The result reveals that radiation and evaporation controlled extremes can be properly decided with both airborne and satellite images. The correlation coefficient of latent heat flux and sensible heat flux with corresponding in situ observations are 0.66 and 0.76, respectively. The relative root mean squared errors (RMSEs) for latent heat flux and sensible heat flux are 97.81 $(W/m^2)$ and 124.33 $(W/m^2)$, respectively. It is also shown that the newly developed retrieval scheme performs well when it is tested by using MODIS date.

  • PDF

타워형 태양열 발전 흡수기의 열유속에 따른 수순환 특성 연구 (Water Circulation Characteristics of a Water/Steam Receiver for Solar Power Tower System at Various Heat Fluxes)

  • 서호영;김종규;강용혁;김용찬
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.1-9
    • /
    • 2008
  • This paper describes water circulation characteristics of a water/steam receiver at various heat fluxes. The water/steam receiver for a solar tower power system is a natural circulation type. Experimental conditions of water and steam were set at a pressure of 5 bar and temperature of $151.8^{\circ}C$. The experimental device for the water/steam receiver consisted of a steam drum, upper/lower header, riser tubes, and downcomer tube. The experiments were conducted by varying heat fluxes in terms of mass flow rate in each riser tube. However, the total mass flow rate on the riser tubes was fixed at 217.4 g/s. For the uniform heat flux, while the water temperature of the steam drum and upper header were kept at steady state, the temperature of the lower header was fluctuated. For the non-uniform heat flux, while the temperature of the steam drum was kept steady state, the temperature difference increased in the right and left side of the upper header, and the temperature of the lower header was fluctuated.

대두 개체군에 있어서 $CO_2$$O_3$ 플럭스 (Flux of Carbon Dioxide and Deposition Velocity of Ozone over Glycine max Canopy)

  • 김원식;이호준
    • The Korean Journal of Ecology
    • /
    • 제23권1호
    • /
    • pp.39-43
    • /
    • 2000
  • 1996년 7월 하순부터 9월 하순에 걸쳐 동경농공대학 농학부 부속부중농장(동경도 부중시)의 대두(Glycine max)개체군을 대상으로 미기상학적 플럭스측정방법의 하나인 열수지법을 이용하여 CO₂ 플럭스와 O₃ 플럭스를 측정하였다. CO₂ 플럭스와 O₃ 플럭스는 엽면적지수(LAI)의 변화에 영향을 받았으며, LAI가 2.0이상일 경우 CO₂ 플럭스는 광합성유효발사량(PAR)과 정비례관계가 있었다. O₃ 플럭스는 측정 기간 중 항상 양의 수치를 나타냈으며, 평균치는 0.5 mol m/sup -2/S/sup -1/이었다. 또한 CO₂와 O₃ 침착속도사이에는 정비례관계가 있었다 (LAI>2.0).

  • PDF

Critical Heat Flux in Uniformly Heated Vertical Annulus Under a Wide Range of Pressures 0.57 to 15.0 MPa

  • Chun, Se-Young;Chung, Heung-June;Hong, Sung-Deok;Yang, Sun-Kyu;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.128-141
    • /
    • 2000
  • The critical heat flux (CHF)experiments have been carried out in a wide range of pressures for an internally heated vertical annulus. The experimental conditions covered ranges of pressures from 0.57 to 15.01 MPa, mass fluxes of 0 kg/$m^2$s and from 200 to 650 kg/$m^2$s, and inlet subcoolings from 85 to 413 kJ/kg. The characteristics of the present data and the effect of pressure on CHF are discussed. Most of the CHFs were identified to dryout of the liquid film in the annular or annular-mist flow. For the mass flux of 200 kg/$m^2$s, there were the indications that the CHF occurred at the transition from annular to annular-mist How in the pressure range of 3~10 MPa. For the mass fluxes of 550 and 650 kg/$m^2$s, the CHFs had a maximum value at a pressure of 2~3 MPa, and the pressure at the maximum CHF values had a trend moving toward the pressure at the peak value of pool boiling CHF as the mass flux decreased. The CHF data under a zero mass flux condition indicate that both the effects of pressure and inlet subcooling on the CHF were smaller, compared with those on the CHF with net water upward flow.

  • PDF

Vegetation Canopy의 접지층 환경에 대한 열적 영향 제1부 : 수치실험 (On the Thermal Effect of Vegetation Canopy to the Surface Sublayer Environment Part 1 : Numerical Experiment)

  • 진병화;황수진
    • 한국환경과학회지
    • /
    • 제8권2호
    • /
    • pp.145-150
    • /
    • 1999
  • To estimate the thermal effect of the vegetation canopy on the surface sublayer environment numerically, we used the combined model of Pielke's1) single layer model for vegetation and Deardorff's2) Force restore method(FRM) for soil layer. Application of present combined model to three surface conditions, ie., unsaturated bare soil, saturated bare soil and saturated vegetation canopy, showed followings; The diurnal temperature range of saturated vegetation canopy is only 20K, while saturated bare soil and unsaturated bare soil surface are 30K, 35K, respectively. The maximum temperature of vegetation canopy occurs at noon, about 2 hours earlier than that of the non-vegetation cases. The peak latent heat fluxes of vegetation canopy is simulated as a 600Wm-2 at 1300 LST. They have higher values during afternoon than beforenoon. Furthermore, the energy redistribution ratios to latent heat fluxes also increased in the late afternoon. Therefore, oasis effect driving from the vegetation canopy is reinforced during late afternoon compared with the non-vegetated conditions.

  • PDF

PERFORMANCE OF TWO DIFFERENT HIGH-ACCURACY UPWIND SCHEMES IN INVISCID COMPRESSIBLE FLOW FIELDS

  • Hosseini R;Rahimian M.H;Mirzaee M
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.99-106
    • /
    • 2005
  • Performance of first, second and third order accurate methods for calculation of in viscid fluxes in fluid flow governing equations are investigated here. For the purpose, an upwind method based on Roe's scheme is used to solve 2-dimensional Euler equations. To increase the accuracy of the method two different schemes are applied. The first one is a second and third order upwind-based algorithm with the MUSCL extrapolation Van Leer (1979), based on primitive variables. The other one is an upwind-based algorithm with the Chakravarthy extrapolation to the fluxes of mass, momentum and energy. The results show that the thickness of shock layer in the third order accuracy is less than its value in second order. Moreover, applying limiter eliminates the oscillations near the shock while increases the thickness of shock layer especially in MUSCL method using Van Albada limiter.

사각 채널에서의 강제대류 열전달 (Forced convective Heat Transfer in rectangular channel)

  • 임태우;유삼상
    • 동력기계공학회지
    • /
    • 제16권4호
    • /
    • pp.37-43
    • /
    • 2012
  • This paper performed experimental research in order to measure boiling heat transfer coefficient of water in microchannel with hydraulic diameter of $500{\mu}m$. Tests were conducted within the ranges of heat fluxes from 100 to 400 kW/$m^2$, vapor qualities from 0 to 0.2, and mass fluxes of 200, 400, and 600 kg/$m^2s$. From the experimental results, it was found that flow boiling heat transfer coefficient is not dependent on mass flux or vapor quality, but instead on heat flux to a certain degree. The measured data of heat transfer are compared to a few available correlations proposed for mini-channels. Among them, Sun and Mishima's correlation is found to predict the present data well, within the mean absolute error of 17.84%.

농림생태계와 대기간의 상호 작용 연구를 위한 에디 공분산 방법의 사용에 관하여 (On Using the Eddy Covariance Method to Study the Interaction between Agro-Forest Ecosystems and the Atmosphere)

  • 최태진;김준;윤진일
    • 한국농림기상학회지
    • /
    • 제1권1호
    • /
    • pp.60-71
    • /
    • 1999
  • The micrometeorological tower flux network is the cornerstone of the global terrestrial vegetation monitoring. The eddy covariance technique used for tower fluxes is derived from the conservation of mass and is most applicable for steady-state conditions over flat, extended, and uniform vegetation. This technique allows us to obtain surface fluxes of energy budget components, greenhouse and trace gases, and other pollutants. The quality-controlled flux data are invaluable to validate various models with temporal scales ranging from minutes to years and spatial scales ranging from a few meters to hundreds of kilometers. In this paper, we review the theoretical background of this important eddy covariance technique, examine the measurement criteria and corrections, and finally suggest some measurement strategies that may facilitate coordinated flux measurements among different disciplines and provide a strong infrastructure for the global flux network.

  • PDF

비유리식(nonglass) 진공관의 진공도가 집열판의 열적 특성에 미치는 영향 (Effect of Vacuum in a Non-glass Vacuum Tube on the thermal behavior of the Absorber Plate)

  • 오승진;현준호;김남진;이윤준;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.67-73
    • /
    • 2008
  • This study has been carried out to investigate the effect of vacuum on the thermal performance of a nonglass evacuated tube. A series of measurements are made indoors to monitor the temperature change of the absorber plate contained in the evacuated tube under different conditions of vacuum and heat fluxes. Those temperatures measured at the thermal equilibrium could be used to assess the heat losses to the ambient in link with the steady operation of non-glass evacuated tubes for solar exploitation.